CoChat

Plasma Renin Activity by LC-MS/MS: Development of a Prototypical Clinical Assay Reveals a Subpopulation of Human Plasma Samples with Substantial Peptidase Activity

Bystrom, Cory E, Salameh, Wael, Reitz, Richard, Clarke, Nigel J · 2010 · Clinical Chemistry
Cited by 79

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: For management and treatment of secondary hypertension, plasma renin activity (PRA) assay is considered an essential diagnostic tool. We developed a liquid chromatography–tandem mass spectrometry (LC-MS/MS)-based approach to PRA offering improvements in laboratory workflow and throughput. During development, we observed a substantial number of clinical samples that have strong degradation activity toward angiotensin (Ang) I during generation. A preliminary characterization of this degradation activity was performed, and we provide here a method by which this degradation can be monitored via the addition of an isotope-labeled degradation standard. METHODS: Automated online sample extraction coupled with HPLC was used to isolate Ang I and internal standard from plasma. The effluent from the analytical column was directed to a triple quadrupole MS operated in selected reaction monitoring mode, monitoring the a5 and b5 product ions from the [M+3H]+3 precursors. Routine analysis could be achieved with as little as 150 μL plasma. RESULTS: We identified both C-terminal and N-terminal degradation products of Ang I using isotope-labeled peptides as controls and substrates. In 2%–5% of patient samples, the degradation essentially eliminated any Ang I produced during generation. CONCLUSIONS: Our method requires reduced sample handling when compared with an RIA and eliminates the need for extended generation times for samples with low renin activity. Degradation of Ang I during generation appears to be a confounding variable in the interpretation of results from some clinical samples. Samples with profound degradation activity can be identified using a degradation standard that is added at the start of generation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2010.146449

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Bystrom, C. E., Salameh, W., Reitz, R., & Clarke, N. J.
Venue
Clinical Chemistry
Published
2010-10-01
Volume
56
Issue
10
Pages
1561-1569
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2130154577
Cited by
79
References
2
FWCI
4.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.