Gross Overestimation of Total Allowable Error Based on Biological Variation
The DOI matches its Crossref record.
Abstract
To the Editor: Westgard was the first to introduce the concept of total error (TE)1 in 1974. Analytical imprecision and bias [i.e., systematic error (SE)] were combined into a single measure of the uncertainty of a test result: ... The factor 1.65 implies that 95% of the results (1-sided) will fall within the TE limit, given a gaussian distribution. When the bias and imprecision are known, the uncertainty of the result can be calculated. When the maximum allowable total error (TEa) is known (e.g., on the basis of clinical needs or biological variation), the maximum allowable bias and imprecision can be calculated. The expression used in general for calculating TEa is: ... Values for CVb, CVw, and TEa are easily available (1), but where does this expression for TEa come from?
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quality control review: implementing a scientifically based quality control system
Westgard, J. O., & Westgard, S. A. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215597248 · Cited by 109
Useful measures and models for analytical quality management in medical laboratories
Westgard, J. O. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0710 · Cited by 64
Biological Variation Estimates Obtained from 91 Healthy Study Participants for 9 Enzymes in Serum
Carobene, A., Røraas, T., Sølvik, U. Ø., Sylte, M. S., Sandberg, S., Guerra, E., Marino, I., Jonker, N., Barla, G., Bartlett, W. A., et al. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.269811 · Cited by 63
Total error vs. measurement uncertainty: revolution or evolution?
Oosterhuis, W. P., & Theodorsson, E. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0997 · Cited by 57
Uncertainty in Measurement and Total Error
Theodorsson, E. (2017) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2016.09.002 · Cited by 54
“There are several variants for how to calculate TE.(45)”
Background
Metadata
- Authors
- Oosterhuis, W. P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-09-01
- Volume
- 57
- Issue
- 9
- Pages
- 1334-1336
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2142900843
- Cited by
- 66
- References
- 0
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gross Overestimation of Total Allowable Error Based on Biological Variation. https://app.cochat.ai/papers/10.1373/clinchem.2011.165308
- The paper
- Oosterhuis, W. P. (2011). Gross Overestimation of Total Allowable Error Based on Biological Variation. Clinical Chemistry. https://doi.org/10.1373/clinchem.2011.165308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.