CoChat

Specificity Characteristics of 7 Commercial Creatinine Measurement Procedures by Enzymatic and Jaffe Method Principles

Greenberg, Neil, Roberts, William L, Bachmann, Lorin M, Wright, Elizabeth C, Dalton, R Neil, Zakowski, Jack J, Greg Miller, W · 2012 · Clinical Chemistry
Cited by 184

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Standardized calibration does not change a creatinine measurement procedure's susceptibility to potentially interfering substances. METHODS: We obtained individual residual serum or plasma samples (n = 365) from patients with 19 different disease categories associated with potentially interfering substances and from healthy controls. Additional sera at 0.9 mg/dL (80 μmol/L) and 3.8 mg/dL (336 μmol/L) creatinine were supplemented with acetoacetate, acetone, ascorbate, and pyruvate. We measured samples by 4 enzymatic and 3 Jaffe commercially available procedures and by a liquid chromatography/isotope dilution/mass spectrometry measurement procedure against which biases were determined. RESULTS: The number of instances when 3 or more results in a disease category had biases greater than the limits of acceptability was 28 of 57 (49%) for Jaffe and 14 of 76 (18%) for enzymatic procedures. For the aggregate group of 59 diabetes samples with increased β-hydroxybutyrate, glucose, or glycosylated hemoglobin (Hb A1c), the enzymatic procedures had 10 biased results of 236 (4.2%) compared with 89 of 177 (50.3%) for the Jaffe procedures, and these interferences were highly procedure dependent. For supplemented sera, interferences were observed in 11 of 24 (46%) of groups for Jaffe and 8 of 32 (25%) of groups for enzymatic procedures and were different at low or high creatinine concentrations. CONCLUSIONS: There were differences in both magnitude and direction of bias among measurement procedures, whether enzymatic or Jaffe. The influence of interfering substances was less frequent with the enzymatic procedures, but no procedure was unaffected. The details of implementation of a method principle influenced its susceptibility to potential interfering substances.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2011.172288

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Greenberg, N., Roberts, W. L., Bachmann, L. M., Wright, E. C., Dalton, R. N., Zakowski, J. J., & Greg Miller, W.
Venue
Clinical Chemistry
Published
2012-02-01
Volume
58
Issue
2
Pages
391-401
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2147729520
Cited by
184
References
1
FWCI
6.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.