CoChat

Kinetic Modeling of Storage Effects on Biomarkers Related to B Vitamin Status and One-Carbon Metabolism

Open access
Hustad, Steinar, Eussen, Simone, Midttun, Øivind, Ulvik, Arve, van de Kant, Puck M, Mørkrid, Lars, Gislefoss, Randi, Ueland, Per M · 2012 · Clinical Chemistry
Cited by 118

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Biomarkers and metabolites related to B vitamin function and one-carbon metabolism have been studied as predictors of chronic diseases in studies based on samples stored in biobanks. For most biomarkers, stability data are lacking or fragmentary. METHODS: Degradation and accumulation kinetics of 32 biomarkers were determined at 23 °C in serum and plasma (EDTA, heparin, and citrate) collected from 16 individuals and stored for up to 8 days. In frozen serum (−25 °C), stability was studied cross-sectionally in 650 archival samples stored for up to 29 years. Concentration vs time curves were fitted to monoexponential, biexponential, linear, and nonlinear models. RESULTS: For many biomarkers, stability was highest in EDTA plasma. Storage effects were similar at room temperature and at −25 °C; notable exceptions were methionine, which could be recovered as methionine sulfoxide, and cystathionine, which decreased in frozen samples. Cobalamin, betaine, dimethylglycine, sarcosine, total homocysteine, total cysteine, tryptophan, asymetric and symmetric dimethyl argenine, creatinine, and methylmalonic acid were essentially stable under all conditions. Most B vitamins (folate and vitamins B2 and B6) were unstable; choline increased markedly, and some amino acids also increased, particularly in serum. The kynurenines showed variable stability. For many biomarkers, degradation (folate and flavin mononucleotide) or accumulation (pyridoxal, riboflavin, choline, amino acids) kinetics at room temperature were non–first order. CONCLUSIONS: Data on stability and deterioration kinetics for individual biomarkers are required to optimize procedures for handling serum and plasma, and for addressing preanalytical bias in epidemiological and clinical studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2011.174490

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 118

Metadata

Authors
Hustad, S., Eussen, S., Midttun, Ø., Ulvik, A., van de Kant, P. M., Mørkrid, L., Gislefoss, R., & Ueland, P. M.
Venue
Clinical Chemistry
Published
2012-02-01
Volume
58
Issue
2
Pages
402-410
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2168570932
Cited by
118
References
1
FWCI
6.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Kinetic Modeling of Storage Effects on Biomarkers Related to B Vitamin Status and One-Carbon Metabolism. https://app.cochat.ai/papers/10.1373/clinchem.2011.174490
The paper
Hustad, S., Eussen, S., Midttun, Ø., Ulvik, A., van de Kant, P. M., Mørkrid, L., Gislefoss, R., & Ueland, P. M. (2012). Kinetic Modeling of Storage Effects on Biomarkers Related to B Vitamin Status and One-Carbon Metabolism. Clinical Chemistry. https://doi.org/10.1373/clinchem.2011.174490

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.