Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 226

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Capture of Viable Circulating Tumor Cells in the Liver of Colorectal Cancer Patients

Denève, Eric, Riethdorf, Sabine, Ramos, Jeanne, Nocca, David, Coffy, Amandine, Daurès, Jean-Pierre, Maudelonde, Thierry, Fabre, Jean-Michel, Pantel, Klaus, Alix-Panabières, Catherine·2013·Clinical Chemistry

Abstract

BACKGROUND: The incidence and number of circulating tumor cells (CTCs) in the peripheral blood of colorectal cancer patients are lower than in other cancer types, which may point to a particular biology of colorectal cancer affecting CTC detection. METHODS: We detected CTCs in the peripheral and mesenteric blood of colorectal cancer patients by use of 2 independent technologies on the basis of different biological properties of colon cancer cells. Seventy-five patients diagnosed with localized (M0, n = 60) and metastatic (M1, n = 15) colorectal cancer were included. Peripheral and mesenteric blood samples were collected before tumor resection. We performed CTC enumeration with an EpCAM-independent enrichment method followed by the Epispot assay that detected only viable CK19-releasing CTCs. In parallel, we used the FDA-cleared EpCAM-dependent CellSearch® as the reference method. RESULTS: The enumeration of CK19-releasing cells by the CK19-Epispot assay revealed viable CTCs in 27 of 41 (65.9%) and 41 of 74 (55.4%) (P = 0.04) patients in mesenteric and peripheral blood, respectively, whereas CellSearch detected CTCs in 19 of 34 (55.9%) and 20 of 69 (29.0%) (P = 0.0046) patients. In mesenteric blood, medians of 4 (range 0–247) and 2.7 CTCs (range 0–286) were found with Epispot and CellSearch (P = 0.2), respectively, whereas in peripheral blood, Epispot and CellSearch detected a median of 1.2 (range 0–92) and 0 CTCs (range 0–147) (P = 0.002). CONCLUSIONS: A considerable portion of viable CTCs detectable by the Epispot assay are trapped in the liver as the first filter organ in CRC patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2013.202846

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 226

Metadata

Authors
Denève, E., Riethdorf, S., Ramos, J., Nocca, D., Coffy, A., Daurès, J.-P., Maudelonde, T., Fabre, J.-M., Pantel, K., & Alix-Panabières, C.
Venue
Clinical Chemistry
Published
2013-09-01
Volume
59
Issue
9
Pages
1384-1392
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2140372606
Cited by
226
References
1
FWCI
6.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Capture of Viable Circulating Tumor Cells in the Liver of Colorectal Cancer Patients. https://app.cochat.ai/papers/10.1373/clinchem.2013.202846
The paper
Denève, E., Riethdorf, S., Ramos, J., Nocca, D., Coffy, A., Daurès, J.-P., Maudelonde, T., Fabre, J.-M., Pantel, K., & Alix-Panabières, C. (2013). Capture of Viable Circulating Tumor Cells in the Liver of Colorectal Cancer Patients. Clinical Chemistry. https://doi.org/10.1373/clinchem.2013.202846

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.