CoChat

Quantification of Tau in Cerebrospinal Fluid by Immunoaffinity Enrichment and Tandem Mass Spectrometry

McAvoy, Thomas, Lassman, Michael E, Spellman, Daniel S, Ke, Zhenlian, Howell, Bonnie J, Wong, Oitak, Zhu, Lan, Tanen, Michael, Struyk, Arie, Laterza, Omar F · 2014 · Clinical Chemistry
Cited by 75

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Cerebrospinal fluid (CSF) tau is a common biomarker for Alzheimer disease (AD). Measurements of tau have historically been performed using immunoassays. Given the molecular diversity of tau in CSF, the selectivity of these immunoassays has often been questioned. Therefore, we aimed to develop an analytically sensitive and selective immunoaffinity liquid chromatography–tandem mass spectrometry (LC-MS/MS) (IA-MS) assay. METHODS: IA-MS sample analysis involved the addition of an internal standard, immunoaffinity purification of tau using a tau monoclonal antibody coupled to magnetic beads, trypsin digestion, and quantification of a surrogate tau peptide by LC-MS/MS using a Waters Trizaic nanoTile ultraperformance LC microfluidic device. Further characterization of tau peptides was performed by full-scan MS using a Thermo Orbitrap LC-MS. CSF samples from a cohort of age-matched controls and patients with AD were analyzed by the IA-MS method as well as a commercially available immunoassay. RESULTS: The IA-MS assay had intra- and interassay imprecision values of 3.2% to 8.1% CV and 7.8% to 18.9% C, respectively, a mean recovery of 106%, and a limit of quantification of 0.25 pmol/L and was able to quantify tau concentrations in all human specimens tested. The IA-MS assay showed a correlation of R2 = 0.950 against a total-tau immunoassay. In patients with AD, tau was increased approximately 2-fold. CONCLUSIONS: Combining immunoaffinity enrichment with microflow LC-MS/MS analysis is an effective approach for the development of a highly selective assay to measure total tau and, potentially, other posttranslationally modified forms of tau in CSF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2013.216515

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 75

Metadata

Authors
McAvoy, T., Lassman, M. E., Spellman, D. S., Ke, Z., Howell, B. J., Wong, O., Zhu, L., Tanen, M., Struyk, A., & Laterza, O. F.
Venue
Clinical Chemistry
Published
2014-04-01
Volume
60
Issue
4
Pages
683-689
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2123597024
Cited by
75
References
5
FWCI
6.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of Tau in Cerebrospinal Fluid by Immunoaffinity Enrichment and Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1373/clinchem.2013.216515
The paper
McAvoy, T., Lassman, M. E., Spellman, D. S., Ke, Z., Howell, B. J., Wong, O., Zhu, L., Tanen, M., Struyk, A., & Laterza, O. F. (2014). Quantification of Tau in Cerebrospinal Fluid by Immunoaffinity Enrichment and Tandem Mass Spectrometry. Clinical Chemistry. https://doi.org/10.1373/clinchem.2013.216515

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.