Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Mass Spectrometry–Based Candidate Reference Measurement Procedure for Quantification of Amyloid-β in Cerebrospinal Fluid

Open access
Leinenbach, Andreas, Pannee, Josef, Dülffer, Thomas, Huber, Andreas, Bittner, Tobias, Andreasson, Ulf, Gobom, Johan, Zetterberg, Henrik, Kobold, Uwe, Portelius, Erik, Blennow, Kaj · 2014 · Clinical Chemistry

Abstract

BACKGROUND: Cerebrospinal fluid (CSF) amyloid-β (Aβ42) is a well-established biomarker for Alzheimer disease. Several immunoassays for Aβ42 exist but differ in absolute concentrations and may suffer from matrix interference, thereby hampering interlaboratory comparisons and the use of general cutoff levels. Together with the IFCC Working Group on CSF Proteins, we developed a candidate reference measurement procedure (RMP) for Aβ42. METHODS: The antibody-independent candidate RMP was based on solid-phase extraction and isotope-dilution LC-MS/MS. The candidate RMP used 2 differently stable isotope-labeled Aβ42 peptides for calibration in human CSF, an important aspect since there was no analyte-free matrix available. Because no CSF certified reference material (CRM) exists, we used a nonlabeled Aβ42 standard, the concentration of which was determined by amino acid analysis. We performed measurements on a high-resolution quadrupole-Orbitrap hybrid instrument. The results were compared with a method run in a second laboratory with triple quadrupole instrumentation. RESULTS: The candidate RMP allowed quantification of CSF Aβ42 from 150 to 4000 pg/mL. Validation of the method showed a recovery of 100% (15%), intraassay and interassay imprecision of 5.0% and 6.4%, respectively, and an expanded uncertainty of 15.7%. No analytical interferences or carryover were detected. CONCLUSIONS: This method will help set the value of CSF Aβ42 in a CRM, which could be used to harmonize Aβ42 assays and facilitate the introduction of general cutoff concentrations for CSF Aβ42 in clinical trials and practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2013.220392

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 159

Metadata

Authors
Leinenbach, A., Pannee, J., Dülffer, T., Huber, A., Bittner, T., Andreasson, U., Gobom, J., Zetterberg, H., Kobold, U., Portelius, E., & Blennow, K.
Venue
Clinical Chemistry
Published
2014-07-01
Volume
60
Issue
7
Pages
987-994
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2106156541
Cited by
159
References
2
FWCI
11.86
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mass Spectrometry–Based Candidate Reference Measurement Procedure for Quantification of Amyloid-β in Cerebrospinal Fluid. https://app.cochat.ai/papers/10.1373/clinchem.2013.220392
The paper
Leinenbach, A., Pannee, J., Dülffer, T., Huber, A., Bittner, T., Andreasson, U., Gobom, J., Zetterberg, H., Kobold, U., Portelius, E., & Blennow, K. (2014). Mass Spectrometry–Based Candidate Reference Measurement Procedure for Quantification of Amyloid-β in Cerebrospinal Fluid. Clinical Chemistry. https://doi.org/10.1373/clinchem.2013.220392

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.