Implementation Of Computerized Physician Order Entry In Seven Countries
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We review the extent and functionality of computerized physician order entry (CPOE) systems in seven Western countries. We compare nations' implementation levels; linkages with other health care information technologies; amount and types of use by clinicians; drivers of implementation; inclusion of decision-support systems and electronic medical records; and goals (for example, patient safety and efficiency). Implementation of CPOE is slower and more problematic than anticipated (adoption rates are 20 percent or less) and often poorly integrated, inducing new errors and generating frustration with user interfaces and repetitive tasks. Nevertheless, the advantages of CPOE remain compelling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260
Overriding of Drug Safety Alerts in Computerized Physician Order Entry
van der Sijs, H., Aarts, J., Vulto, A., & Berg, M. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1809 · Cited by 1,117
Self-citationThe use of health information technology in seven nations
Jha, A. K., Doolan, D., Grandt, D., Scott, T., & Bates, D. W. (2008) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2008.06.007 · Cited by 420
High Rates of Adverse Drug Events in a Highly Computerized Hospital
(2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.10.1111 · Cited by 363
Massaro, T. A. (1993) · Academic Medicine · doi:10.1097/00001888-199301000-00003 · Cited by 287
Shulman, R., Singer, M., Goldstone, J., & Bellingan, G. (2005) · Critical Care · doi:10.1186/cc3793 · Cited by 252
Health information exchange and patient safety
Kaelber, D. C., & Bates, D. W. (2007) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2007.08.011 · Cited by 206
Hiding in plain sight: What Koppel et al. tell us about healthcare IT
Nemeth, C., & Cook, R. (2005) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2005.05.010 · Cited by 34
Cited by
Lluch, M. (2011) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2011.09.005 · Cited by 358
van der Veen, W., van den Bemt, P. M., Wouters, H., Bates, D. W., Twisk, J. W., de Gier, J. J., Taxis, K., for the BCMA Study Group, Duyvendak, M., Luttikhuis, K. O., et al. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocx077 · Cited by 64
Mazur, L. M., Mosaly, P. R., Moore, C., Comitz, E., Yu, F., Falchook, A. D., Eblan, M. J., Hoyle, L. M., Tracton, G., Chera, B. S., et al. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw016 · Cited by 45
Metadata
- Authors
- Aarts, J., & Koppel, R.
- Venue
- Health Affairs
- Publisher
- Health Affairs Publishing, LLC
- Published
- 2009-03
- Volume
- 28
- Issue
- 2
- Pages
- 404-414
- ISSN
- 0278-2715 (ISSN-L)
- 1544-5208
- OpenAlex
- W2029725421
- Cited by
- 114
- References
- 8
- FWCI
- 27.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.