Cited by 80Obstructive Sleep Apnea ResearchSleep and related disordersNeuroscience of respiration and sleep

Respiratory Polygraphy With Actigraphy in the Diagnosis of Sleep Apnea-Hypopnea Syndrome

García-Díaz, Emilio, Quintana-Gallego, Esther, Ruiz, Aránzazu, Carmona-Bernal, Carmen, Sánchez-Armengol, ángeles, Botebol-Benhamou, Georgina, Capote, Francisco·2007·Chest

Abstract

Objective To determine the utility and reliability of a respiratory polygraphy (RP) device with actigraphy (Apnoescreen II; Erich Jaeger GMBH & CoKg; Wuerzburg, Germany) in the diagnosis of sleep apnea-hypopnea syndrome (SAHS). Design A prospective randomized study with blinded analysis. Patients Sixty-two patients with suspected SAHS. Measurements the following two RP studies were performed: one in the sleep laboratory (sleep laboratory RP [LRP]), simultaneously with polysomnography; and the other at home (home RP [HRP]). To study the interobserver reliability of RP, two manual analyses were carried out by two different researchers. Results In LRP, when the respiratory disturbance index was calculated using the total sleep time estimated by actigraphy (RDI) as a denominator, the sensitivity ranged between 94.6% and 100%, and the specificity between 88% and 96.7% for the different cutoff points of the apnea-hypopnea indexes studied. When the respiratory disturbance index was calculated according to the total recording time (RDITRT), the sensitivity was slightly lower (91.6 to 96.9%) and the specificity was similar (92 to 96.7%). In HRP, the sensitivity of the RDI ranged between 83.8% and 95.8%, and the specificity between 92% and 100%, whereas, when the RDITRT was used, the sensitivity was between 83.8% and 87.5%, and the specificity was between 94.7% and 100%. With regard to interobserver reliability, the intraclass correlation coefficient for the RDI of the two analyses of…

Integrity signals

Registry

Crossref · 10.1378/chest.06-1604

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
García-Díaz, E., Quintana-Gallego, E., Ruiz, A., Carmona-Bernal, C., Sánchez-Armengol, Á., Botebol-Benhamou, G., & Capote, F.
Affiliations
Hospital Universitario Virgen del Rocío (ES)
Corresponding author
García-Díaz, Emilio
Venue
Chest
Publisher
Elsevier BV
Published
2007-03
Volume
131
Issue
3
Pages
725-732
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2078385819
Cited by
80
References
2
Citations by year
2025: 1 · 2024: 3 · 2023: 3 · 2022: 4 · 2021: 2 · 2020: 4 · 2019: 2 · 2018: 5 · 2017: 7 · 2016: 3 · 2015: 15 · 2014: 6 · 2013: 6
FWCI
2.75
Type
journal article
Language
en
Open access
closed
Locations
  • CHEST Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
Keywords
sleep apnea-hypopnea syndrome, respiratory polygraphy, actigraphy, home sleep testing, respiratory disturbance index, sensitivity and specificity, inter-rater reliability, apnea-hypopnea index
MeSH terms
Adult, Aged, Equipment Design, Female, Humans, Male, Middle Aged, Prospective Studies, Pulmonary Ventilation, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Software, Statistics as Topic, Observer Variation, Polysomnography, Monitoring, Ambulatory, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review