STUDY OBJECTIVES: To compare short-term outcomes following bilateral lung volume reduction surgery performed by median sternotomy (MS) and video-assisted thoracoscopic surgery (VATS). METHODS: Bilateral lung volume reduction surgery was performed by MS in 80 patients and by VATS in 40. All patients underwent preoperative assessment with pulmonary function testing, arterial blood gas determination, and 6-min walk test (6MWT). Pulmonary function testing and 6MWT were repeated at 3 to 6 months postoperatively. RESULTS: The mean age of the VATS group was lower than that of the MS group (59.3 +/- 9.4 vs 62.4 +/- 6.9 years; p = 0.001), but there were no differences in baseline functional parameters of disease severity (FEV1, FVC, residual volume [RV], arterial PCO2, or 6MWT). All patients in both groups were extubated at the completion of surgery, but 17.5% of patients in the MS group and 2.5% in the VATS group (p = 0.02) subsequently required reintubation at some point during the postoperative course. Thirty-day operative mortality was 4.2% for the MS group and 2.5% for the VATS group (p = not significant). However, total in-hospital mortality was 13.8% for the MS group, while it remained 2.5% for the VATS group (p = 0.05). Mortality was largely confined to patients 65 years of age or older. There was no significant difference in duration of air leaks or length of hospital stay between the two groups. Functional outcomes achieved with the two techniques were similar. Specifically, there was no difference between the two groups in mean postoperative FEV1, FVC, RV, or 6MWT, or in the magnitude of change in these parameters over preoperative values. CONCLUSIONS: Bilateral lung volume reduction surgery performed by either MS and VATS approaches leads to similar improvements in pulmonary function and exercise tolerance. VATS is associated with a significantly lower incidence of respiratory failure and a trend toward decreased in-hospital mortality and may be the preferred technique, particularly for high-risk patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1378/chest.110.6.1399

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 124

Metadata

Authors
Kotloff, R. M., Tino, G., Baυaria, J. E., Palevsky, H. I., Hansen-Flaschen, J., Wahl, P. M., & Kaiser, L. R.
Venue
Chest
Publisher
Elsevier BV
Published
1996-12
Volume
110
Issue
6
Pages
1399-1406
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2041532866
Cited by
124
References
0
FWCI
19.06
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bilateral Lung Volume Reduction Surgery for Advanced Emphysema. https://app.cochat.ai/papers/10.1378/chest.110.6.1399
The paper
Kotloff, R. M., Tino, G., Baυaria, J. E., Palevsky, H. I., Hansen-Flaschen, J., Wahl, P. M., & Kaiser, L. R. (1996). Bilateral Lung Volume Reduction Surgery for Advanced Emphysema. Chest. https://doi.org/10.1378/chest.110.6.1399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.