Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 330

The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.

Radiofrequency Volumetric Tissue Reduction of the Palate in Subjects With Sleep-Disordered Breathing

Open access
Powell, Nelson B., Riley, Robert W., Troell, Robert J., Li, Kasey, Blumen, Marc B., Guilleminault, Christian·1998·Chest

Abstract

STUDY OBJECTIVES: To evaluate pain, swallowing, speech, edematous response, tissue shrinkage, sleep, snoring, and safety (energy limits and adverse effects) following radiofrequency (RF) treatment to the palate in 22 subjects with sleep-disordered breathing. DESIGN: This investigation is a prospective nonrandomized study. Polysomnography, radiographic imaging, and infrared thermography, along with questionnaires and visual analog scales, were used to evaluate the effects of RF treatment to the palate. SETTING: Treatments were delivered on an outpatient basis at Stanford University Medical Center. PATIENTS: Twenty-two healthy patients (18 men), with a mean age of 45.3+/-9.1 years, were enrolled. All were snorers seeking treatment and met predetermined criteria: a respiratory disturbance index < or = 15, oxygen saturation > or = 85%, and a complaint of daytime sleepiness. INTERVENTION: RF was delivered to the submucosa of the palate with a custom-fabricated electrode for a mean duration of 141+/-30 s with a mean of 3.6+/-1.2 treatments per patient. Reduction of their snoring scores determined the end point of the study. RESULTS: Neither speech nor swallowing was adversely affected. Pain was of short duration (0 to 48 h) and was controlled with acetaminophen. There were no infections. Although there was documented edema at 24 to 48 h, there were no clinical airway compromises. Polysomnographic data showed improvement in esophageal pressure measurements of the mean nadir and the 95th percentile nadir (p=0.031, p=0.001) respectively, as well as the mean sleep efficiency index (p=0.002). Radiographic imaging showed a mean shrinkage of 5.5+/-3.7 mm (p< or =0.0001). Subjective snoring scores fell by a mean of 77% (8.3+/-1.8 to 1.9+/-1.7, p=0.0001) accompanied by improved mean Epworth sleepiness scores (8.5+/-4.4 to 5.2+/-3.3, p=0.0001). CONCLUSION: The results of this investigation allowed the formulation of safety parameters for RF in this defined population with mild sleep-disordered breathing. There was a documented tissue reduction and improvement in symptoms in all subjects. However, given the small sample size and short-term follow-up, these results should be confirmed by further investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1378/chest.113.5.1163

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 57 references

Cited by

See all 330

Metadata

Authors
Powell, N. B., Riley, R. W., Troell, R. J., Li, K., Blumen, M. B., & Guilleminault, C.
Venue
Chest
Publisher
Elsevier BV
Published
1998-05
Volume
113
Issue
5
Pages
1163-1174
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2080271312
Cited by
330
References
57
FWCI
14.86
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiofrequency Volumetric Tissue Reduction of the Palate in Subjects With Sleep-Disordered Breathing. https://app.cochat.ai/papers/10.1378/chest.113.5.1163
The paper
Powell, N. B., Riley, R. W., Troell, R. J., Li, K., Blumen, M. B., & Guilleminault, C. (1998). Radiofrequency Volumetric Tissue Reduction of the Palate in Subjects With Sleep-Disordered Breathing. Chest. https://doi.org/10.1378/chest.113.5.1163

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.