CoChat

Obstructive Sleep Apnea in Patients With Typical Atrial Flutter

Bazan, Victor, Grau, Nuria, Valles, Ermengol, Felez, Miquel, Sanjuas, Carles, Cainzos-Achirica, Miguel, Benito, Begoña, Jauregui-Abularach, Miguel, Gea, Joaquim, Bruguera-Cortada, Jordi, Marti-Almor, Julio · 2013 · Chest

The DOI matches its Crossref record; 36 of the 37 references it cites were found in a registry or an index.

Abstract

Background The clinical yield of cavotricuspid isthmus (CTI) radiofrequency ablation of atrial flutter (AF) is limited by a high incidence of atrial fibrillation (AFib) in the long term. Among other acknowledged variables, the association of obstructive sleep apnea (OSA) could favor incomplete arrhythmia control in this setting. We assessed the impact of CPAP in reducing the occurrence of AFib after CTI ablation. Methods Consecutive patients with AF who were undergoing CTI ablation were screened for OSA. Relationship of the following variables with the occurrence of AFib during follow-up (12 months) was investigated: CPAP initiation, hypertension, BMI, underlying structural heart disease, left atrial diameter, and AFib documentation prior to ablation. Results We prospectively included 56 patients (mean age: 66 (± 11) years; 12 female patients), of whom 46 (82%) had OSA and 25 (45%) had severe OSA. Twenty-one patients (38%) had AFib during follow-up after CTI ablation. Both freedom from AFib prior to ablation and CPAP initiation in those patients without previously documented AFib at inclusion were associated with a reduction of AFib episodes during follow-up (P = .019 and P = .025, respectively). Inversely, CPAP was not protective from AFib recurrence when this arrhythmia was documented prior to ablation (P = .25). Conclusions OSA is a prevalent condition in patients with AF. Treatment with CPAP is associated with a lower incidence of newly diagnosed AFib after CTI ablation.…

Overview

Integrity signals

Registry

Crossref · 10.1378/chest.12-0697

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 54

Metadata

Authors
Bazan, V., Grau, N., Valles, E., Felez, M., Sanjuas, C., Cainzos-Achirica, M., Benito, B., Jauregui-Abularach, M., Gea, J., Bruguera-Cortada, J., & Marti-Almor, J.
Affiliations
Universitat Autònoma de Barcelona (ES)
Venue
Chest
Publisher
Elsevier BV
Published
2013-05
Volume
143
Issue
5
Pages
1277-1283
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2048932339
Cited by
54
References
37
Citations by year
2025: 1 · 2024: 3 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 3 · 2018: 6 · 2017: 1 · 2016: 3 · 2015: 11 · 2014: 7 · 2013: 7
FWCI
6.37
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • CHEST Journal (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Bayer
  • ResMed
  • Menarini Group
  • Johnson and Johnson
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
Keywords
obstructive sleep apnea, atrial flutter, atrial fibrillation recurrence, cavotricuspid isthmus ablation, continuous positive airway pressure, OSA screening, arrhythmia control, hypertension, obesity
MeSH terms
Aged, Atrial Fibrillation, Atrial Flutter, Female, Follow-Up Studies, Humans, Hypertension, Male, Middle Aged, Prospective Studies, Body Mass Index, Incidence, Prevalence, Multivariate Analysis, Logistic Models, Treatment Outcome, Catheter Ablation, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.