The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
An Overlying Fat Panniculus Affects Femur Bone Mass Measurement
Abstract
Dual-energy X-ray absorptiometry (DXA) is currently the gold standard technique for osteoporosis diagnosis. However, DXA has limitations, including artifacts, such as degenerative disease or metallic foreign bodies, that may confound bone mineral density (BMD) results. Because fat folds overlying the proximal femur may alter soft-tissue density in a nonuniform manner, this may be a currently unappreciated confounder of proximal femur BMD measurement. This possibility was evaluated in 127 patients (52 women/75 men) referred for routine BMD measurement who were identified as having a fat panniculus overlying their proximal femur scan area. Presence of a fat panniculus within the scan field was confirmed by visual assessment of images obtained utilizing a GE Lunar Expert-XL. Subsequently, these individuals were rescanned while retracting their fat panniculus away from the femur scan area without other repositioning between scans. In 49% of the men, and 56% of the women, either the femoral neck, trochanter, or total femur BMD differed by more than the least significant change at our facility. No pattern was observed to predict whether BMD would increase or decrease upon fat retraction. Subsequently, 30 patients were scanned using the standard and retracted technique twice, with repositioning between scans to establish precision. Retracted and standard precision was similar. In conclusion, an overlying fat panniculus may alter proximal femur BMD measurement, which would be expected to impair the ability to accurately diagnose low bone mass and monitor osteoporosis therapy. When a fat panniculus overlays the proximal femur scan area, its retraction should be part of routine densitometric practice.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Limitations due to DXA technology include the fact that obesity itself and changes in fat mass introduce artifacts that may compromise accuracy and precision.30-33”
From Bone loss after bariatric surgery: causes, consequences, and management (2014) · cites this paper as [33]
Citations
Cites
Professor Kanis, J. A., Melton, L. J., Christiansen, C., Johnston, C. C., & Khaltaev, N. (1994) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650090802 · Cited by 3,849
ORWOLL, E. S., Oviatt, S. K., & MANN, T. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-70-4-1202 · Cited by 307
Svendsen, O. L., Hassager, C., Skødt, V., & Christiansen, C. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100607 · Cited by 184
Influence of degenerative joint disease on spinal bone mineral measurements in postmenopausal women
Yu, W., Gl�er, C. C., Fuerst, T., Grampp, S., Li, J., Lu, Y., & Genant, H. K. (1995) · Calcified Tissue International · doi:10.1007/bf00310253 · Cited by 154
Perspective : The diagnosis of osteoporosis
Kanis, J. (1994) · Medical Entomology and Zoology · Cited by 150
Hansen, M. A., Hassager, C., Overgaard, K., Marslew, U., Riis, B. J., & Christiansen, C. (1990) · PubMed · Cited by 126
Errors due to non-uniform distribution of fat in dual X-ray absorptiometry of the lumbar spine
Tothill, P., & Pye, D. (1992) · British Journal of Radiology · doi:10.1259/0007-1285-65-777-807 · Cited by 107
Holbrook, T. L., & Barrett-Connor, E. L. (1993) · Bone and Mineral · doi:10.1016/s0169-6009(08)80023-2 · Cited by 104
Tothill, P., & Avenell, A. (1994) · British Journal of Radiology · doi:10.1259/0007-1285-67-793-71 · Cited by 81
Bone Densitometry for Technologists
Bonnick, S. L., & Lewis, L. A. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3625-6 · Cited by 67
Antonacci, M. D., Hanson, D. S., LeBlanc, A., & Heggeness, M. H. (1997) · Spine · doi:10.1097/00007632-199710150-00014 · Cited by 49
Dual-Energy X-Ray Absorptiometric Densitometry in Osteoarthritis of the Hip
Preidler, K., White, L. M., Tashkin, J., McDaniel, C. O., BROSSMANN, J., Andresen, R., & Sartoris, D. J. (1997) · Acta Radiologica · doi:10.1080/02841859709174383 · Cited by 30
Measured femoral density by dual-energy X-ray absorptiometry as a function of rotation.
Girard, M. S., Sartoris, D. J., Aa, M., & Ramos, E. (1994) · PubMed · Cited by 21
Increased Hip Bone Mineral Density in a Woman with Gluteal Silicon Implant
Hauache, O. M., Gilberto, H. V. J., Alonso, G., Martins, L. R. F., & Brandão, C. M. A. (2000) · Journal of Clinical Densitometry · doi:10.1385/jcd:3:4:391 · Cited by 20
Valkema, R., Verheij, L. F., Blokland, J. A. K., Zwinderman, A. H., Bijvoet, O. L. M., Papapoulos, S. E., & Pauwels, E. K. J. (1990) · PubMed · Cited by 19
Bone Densitometry For Technologists
Murphy, C. (2003) · Canadian Journal of Medical Radiation Technology · doi:10.1016/s0820-5930(09)60016-5 · Cited by 8
Precision in Bone Densitometry
Bonnick, S. L., & Lewis, L. A. (2002) · Humana Press eBooks · doi:10.1007/978-1-59259-123-7_6 · Cited by 4
Increased Bone Mineral Density in a Man with Known Compression Fractures
Adler, R. A., Nordlie, R. R., & BURKE, T. S. (1998) · Journal of Clinical Densitometry · doi:10.1385/jcd:1:3:275 · Cited by 4
Dual-Energy X-Ray Absorptiometric Densitometry in Osteoarthritis of the Hip
Preidler, K., White, L. S., Tashkin, J., et al. (1997) · Acta Radiologica · doi:10.3109/02841859709174383 · Cited by 1
Research works printed but not linked: 1
- Jankowski, 2002, Panniculus adiposus: an unpredictable and often unrecognized source of precision and accuracy errors on DXA scans of the proximal femur, J Clin Densitom, 5, SupplS57
Cited by
Sorted by citations
Osteoporosis Imaging: State of the Art and Advanced Imaging
Link, T. M. (2012) · Radiology · doi:10.1148/radiol.12110462 · Cited by 460
Lingvay, I., Cohen, R. V., Roux, C. W. L., & Sumithran, P. (2024) · The Lancet · doi:10.1016/s0140-6736(24)01210-8 · Cited by 433
Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT
Yu, E. W., Thomas, B. J., Brown, J. K., & Finkelstein, J. S. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.506 · Cited by 300
Obesity and fracture in men and women: an epidemiologic perspective
Nielson, C. M., Srikanth, P., & Orwoll, E. S. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1486 · Cited by 253
Bone Metabolism After Bariatric Surgery
Yu, E. W.-Y. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2226 · Cited by 218
Metadata
- Authors
- Binkley, N., Krueger, D., & Vallarta-Ast, N.
- Affiliations
- University of Wisconsin–Madison (US)
- William S. Middleton Memorial Veterans Hospital (US)
- Corresponding author
- Binkley, Neil
- ORCID
- Binkley, Neil
- Venue
- Journal of Clinical Densitometry
- Publisher
- Elsevier BV
- Published
- 2003-09
- Volume
- 6
- Issue
- 3
- Pages
- 199-204
- ISSN
- 1094-6950 (ISSN-L)
- OpenAlex
- W2016893819
- Cited by
- 90
- References
- 18
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 5 · 2022: 4 · 2021: 4 · 2020: 8 · 2019: 3 · 2018: 2 · 2017: 4 · 2016: 1 · 2015: 4 · 2014: 11 · 2013: 8 · 2012: 10
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Clinical Densitometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- soft tissue artifacts, dual-energy X-ray absorptiometry, osteoporosis diagnosis, measurement precision, femoral neck, trochanter, osteopenia
- MeSH terms
- Adipose Tissue, Aged, Female, Femur, Humans, Male, Absorptiometry, Photon, Bone Density, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review