Liver Stiffness Measurement With FibroScan: Use the Right Probe in the Right Conditions!
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: FibroScan's M and XL probes give significantly different results, which could lead to misevaluation of liver fibrosis if the correct probe is not chosen. According to the manufacturer, the M probe should be used when the skin–liver capsule distance (SCD) is <25 mm, and the XL probe should be used when SCD is ≥25 mm. We aimed at validating this recommendation and defining the conditions of use for FibroScan probes in clinical practice. METHODS: Four hundred thirty-nine patients with biopsy-proven chronic liver disease were included. Of them, 382 had successful examinations with both M and XL probes. Advanced fibrosis was defined as Nonalcoholic Steatohepatitis Clinical Research Network (NASH CRN) F ≥3 or Metavir F ≥2. RESULTS: In a same patient, XL probe results were significantly lower than M probe results: 7.9 (5.6–11.7) vs 9.5 (6.7–14.6) kPa, respectively (P < 0.001). After matching for age, sex, liver fibrosis, and serum transaminases, M probe results in patients with SCD <25 mm and XL probe results in those with SCD ≥25 mm did not significantly differ: 8.8 (6.0–12.0) vs 9.1 (6.7–12.8) kPa, respectively (P = 0.175). Of note, 81.4% of patients with body mass index (BMI) <32 kg/m 2 had SCD <25 mm, and 77.7% of patients with BMI ≥32 kg/m 2 had SCD ≥25 mm. A practical algorithm using BMI first and then the FibroScan Automatic Probe Selection tool was proposed to help physicians accurately choose which probe to use in clinical practice. CONCLUSIONS: There is no significant difference in results between M and XL probes when they are used in the right conditions. In clinical practice, the probe should be selected according to the BMI and the Automatic Probe Selection tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
Xiao, G., Zhu, S., Xiao, X., Yan, L., Yang, J., & Wu, G. (2017) · Hepatology · doi:10.1002/hep.29302 · Cited by 895
Cited by
Sterling, R. K., Duarte-Rojo, A., Patel, K., Asrani, S. K., Alsawas, M., Dranoff, J. A., Fiel, M. I., Murad, M. H., Leung, D. H., Levine, D., et al. (2025) · Hepatology · doi:10.1097/hep.0000000000000843 · Cited by 215
Liver fibrosis assessment: MR and US elastography
Ozturk, A., Olson, M. C., Samir, A. E., & Venkatesh, S. K. (2021) · Abdominal Radiology · doi:10.1007/s00261-021-03269-4 · Cited by 168
Cassinotto, C., Boursier, J., Paisant, A., Guiu, B., Irles‐Depe, M., Canivet, C., Aube, C., & de Ledinghen, V. (2021) · Hepatology · doi:10.1002/hep.31655 · Cited by 55
Authors, & Collaborators: (2022) · Zeitschrift für Gastroenterologie · doi:10.1055/a-1880-2388 · Cited by 30
Metadata
- Authors
- Berger, A., Shili, S., Zuberbuhler, F., Hiriart, J.-B., Lannes, A., Chermak, F., Hunault, G., Foucher, J., Oberti, F., Fouchard-Hubert, I., Cales, P., de Ledinghen, V., & Boursier, J.
- Venue
- Clinical and Translational Gastroenterology
- Published
- 2019-04
- Volume
- 10
- Issue
- 4
- Pages
- e00023
- ISSN
- 2155-384X (ISSN-L)
- OpenAlex
- W2940540170
- Cited by
- 52
- References
- 2
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liver Stiffness Measurement With FibroScan: Use the Right Probe in the Right Conditions! https://app.cochat.ai/papers/10.14309/ctg.0000000000000023
- The paper
- Berger, A., Shili, S., Zuberbuhler, F., Hiriart, J.-B., Lannes, A., Chermak, F., Hunault, G., Foucher, J., Oberti, F., Fouchard-Hubert, I., Cales, P., de Ledinghen, V., & Boursier, J. (2019). Liver Stiffness Measurement With FibroScan: Use the Right Probe in the Right Conditions! Clinical and Translational Gastroenterology. https://doi.org/10.14309/ctg.0000000000000023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.