CoChat

Measurement of Flash Points for n-hexanol+n-butyric acid and n-butanol+propionic acid by Seta-flash Closed Cup Method

Ha, Dong-Myeong, Lee, Sungjin · 2014 · Journal of the Korean Society of Safety
Cited by 1

The DOI matches its Crossref record.

Abstract

The flash point is one of the most important physical properties used to determine the fire hazard of flammable liquid mixture and defined as the lowest temperature at which a liquid produces sufficient vapor to form a combustible mixture with air. The main purpose of this paper is to measure and predict the flash point of binary flammable miscible mixtures. The flash points for n-hexanol+n-butyric acid and n-butanol+propionic acid, were measured by using Seta-flash closed cup method. The experimentally derived data were correlated with the binary interaction parameters of the van Laar and NRTL equations through the optimization method. The flash points estimated by these correlations were compared with those calculated by the method based on Raoult's law. The optimization method were found to be better than the method based on the Raoult's law.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.14346/jkosos.2014.29.6.076

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 11

  1. 10.1016/S0950-4230(01)00062-6 · doi:10.1016/s0950-4230(01)00062-6
  2. 2006, Fluid Phsae Equilibria, 312, 101
  3. 10.1016/0304-3894(79)85008-6 · DOI · Paper page
  4. 10.1021/je60055a040 · DOI · Paper page
  5. 10.1016/S0379-7112(96)00070-7 · DOI · Paper page
  6. 10.1016/S0950-4230(02)00068-2 · DOI · Paper page
  7. 10.1007/s11814-007-0001-2 · doi:10.1007/s11814-007-0001-2
  8. 10.1021/i100006a016 · doi:10.1021/i100006a016
  9. 10.1016/j.fluid.2014.05.016 · doi:10.1016/j.fluid.2014.05.016
  10. 10.1007/s11814-010-0478-y · DOI
  11. 10.1007/s11814-012-0099-8 · DOI

Cited by

See all 1

Metadata

Authors
Ha, D.-M., & Lee, S.
Venue
Journal of the Korean Society of Safety
Published
2014-12-31
Volume
29
Issue
6
Pages
76-80
ISSN
1738-3803
Cited by
1
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Flash Points for n-hexanol+n-butyric acid and n-butanol+propionic acid by Seta-flash Closed Cup Method. https://app.cochat.ai/papers/10.14346/jkosos.2014.29.6.076
The paper
Ha, D.-M., & Lee, S. (2014). Measurement of Flash Points for n-hexanol+n-butyric acid and n-butanol+propionic acid by Seta-flash Closed Cup Method. Journal of the Korean Society of Safety. https://doi.org/10.14346/jkosos.2014.29.6.076

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.