CoChat

A Study of Potential Toxic Effects After Repeated 10-Week Administration of a New Iron Chelator – Salicylaldehyde Isonicotinoyl Hydrazone (SIH) to Rabbits

Open access
Klimtová, Ivona, Šimůnek, Tomáš, Mazurová, Yvona, Kaplanová, Jana, Štěrba, Martin, Hrdina, Radomír, Geršl, Vladimír, Adamcová, Michaela, Poňka, Přemysl · 2003 · Acta Medica (Hradec Kralove, Czech Republic)
Cited by 20

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Salicylaldehyde Isonicotinoyl Hydrazone (SIH) – a Pyridoxal Isonicotinoyl Hydrazone (PIH) analogue – is an effective iron chelator with antioxidant and antimalarial effects, as documented in numerous in vitro studies. However, no toxicological data obtained from in vivo studies have been made available yet. In this study, the potential toxic effects of repeated administration of SIH (50 mg/kg, once weekly, 10 weeks, i.p.), partially dissolved in a 10 % Cremophor solution, on various biochemical, haematological, and cardiovascular parameters and on morphology of selected tissues were investigated in rabbits. The obtained values were compared with data from the control (saline, 1 ml/kg, i.v.) and the Cremophor (10 % Cremophor solution, 2 ml/kg, i.p.) groups. In this study, SIH did not induced marked signs of toxicity: No premature deaths occurred, the body weight increase was comparable with the control and Cremophor groups. Only few and mild changes in some biochemical and haematological parameters could be determined, most of them were noticed also in the control or Cremophor groups. The morphological changes in the kidney were mild and did not manifest in the biochemical examination. The cardiac function was also not affected markedly – the values of left ventricular ejection fraction and systolic time interval did not differ from the values of control group. Only an increased left ventricular contractility (dP/dt max ) was noticed in the SIH group at the end of the experiment as compared to the controls (13354±1191 vs. 9339±647 mmHg/s, resp.). These results seem to be promising from the standpoint of possible clinical use of SIH.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.14712/18059694.2019.27

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 20

Metadata

Authors
Klimtová, I., Šimůnek, T., Mazurová, Y., Kaplanová, J., Štěrba, M., Hrdina, R., Geršl, V., Adamcová, M., & Poňka, P.
Venue
Acta Medica (Hradec Kralove, Czech Republic)
Published
2003
Volume
46
Issue
4
Pages
163-170
ISSN
  • 1211-4286 (ISSN-L)
  • 1805-9694
OpenAlex
W2428126260
Cited by
20
References
2
FWCI
0.10
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Study of Potential Toxic Effects After Repeated 10-Week Administration of a New Iron Chelator – Salicylaldehyde Isonicotinoyl Hydrazone (SIH) to Rabbits. https://app.cochat.ai/papers/10.14712/18059694.2019.27
The paper
Klimtová, I., Šimůnek, T., Mazurová, Y., Kaplanová, J., Štěrba, M., Hrdina, R., Geršl, V., Adamcová, M., & Poňka, P. (2003). A Study of Potential Toxic Effects After Repeated 10-Week Administration of a New Iron Chelator – Salicylaldehyde Isonicotinoyl Hydrazone (SIH) to Rabbits. Acta Medica (Hradec Kralove, Czech Republic). https://doi.org/10.14712/18059694.2019.27

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.