The DOI matches its Crossref record; 152 of the 152 references it cites were found in a registry or an index.
Troponin: the biomarker of choice for the detection of cardiac injury
Open accessAbstract
It has been known for 50 years that transaminase activity increases in patients with acute myocardial infarction. With the development of creatine kinase (CK), biomarkers of cardiac injury began to take a major role in the diagnosis and management of patients with acute cardiovascular disease. In 2000 the European Society of Cardiology and the American College of Cardiology recognized the pivotal role of biomarkers and made elevations in their levels the “cornerstone” of diagnosis of acute myocardial infarction. At that time, they also acknowledged that cardiac troponin I and T had supplanted CK-MB as the analytes of choice for diagnosis. In this review, we discuss the science underlying the use of troponin biomarkers, how to interpret troponin values properly and how to apply these measurements to patients who present with possible cardiovascular disease. Troponin is the biomarker of choice for the detection of cardiac injury. To use it properly, one must understand how sensitive the specific assay being used is for detecting cardiac injury, the fact that elevated troponin levels are highly specific for cardiac injury and some critical issues related to the basic science of the protein and its measurement. In this article, we review the biology of troponin, characteristics of assays that measure serum troponin levels and how to apply these measurements to patients who present with possible cardiovascular disease. We also discuss other clinical situations in which troponin levels may be elevated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2001) · New England Journal of Medicine · doi:10.1056/nejmoa010746 · Cited by 6,470
Antman, E., Bassand, J.-P., Klein, W., Ohman, M., Lopez Sendon, J. L., Rydén, L., Simoons, M., & Tendera, M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00804-4 · Cited by 4,821
Cannon, C. P., Weintraub, W. S., Demopoulos, L. A., Vicari, R., Frey, M. J., Lakkis, N., Neumann, F.-J., Robertson, D. H., DeLucca, P. T., DiBattiste, P. M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106213442501 · Cited by 2,103
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Profound but Reversible Myocardial Depression in Patients with Septic Shock
PARKER, M. M., SHELHAMER, J. H., BACHARACH, S. L., GREEN, M. V., NATANSON, C., FREDERICK, T. M., DAMSKE, B. A., & PARRILLO, J. E. (1984) · Annals of Internal Medicine · doi:10.7326/0003-4819-100-4-483 · Cited by 1,585
Lindahl, B., Toss, H., Siegbahn, A., Venge, P., & Wallentin, L. (2000) · New England Journal of Medicine · doi:10.1056/nejm200010193431602 · Cited by 1,224
Cardiac troponin I. A marker with high specificity for cardiac injury.
Adams, J. E., Bodor, G. S., Dávila-Román, V. G., Delmez, J. A., Apple, F. S., Ladenson, J. H., & Jaffe, A. S. (1993) · Circulation · doi:10.1161/01.cir.88.1.101 · Cited by 1,148
Self-citationCardiac Troponin T Levels for Risk Stratification in Acute Myocardial Ischemia
Ohman, E. M., Armstrong, P. W., Christenson, R. H., Granger, C. B., Katus, H. A., Hamm, C. W., O’Hanesian, M. A., Wagner, G. S., Kleiman, N. S., Harrell, F. E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351801 · Cited by 1,114
Cited by
Pathobiology of Troponin Elevations
White, H. D. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.029 · Cited by 381
Laverty, H., Benson, C., Cartwright, E., Cross, M., Garland, C., Hammond, T., Holloway, C., McMahon, N., Milligan, J., Park, B., et al. (2011) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2011.01255.x · Cited by 363
Top‐down proteomics in health and disease: Challenges and opportunities
Gregorich, Z. R., & Ge, Y. (2014) · PROTEOMICS · doi:10.1002/pmic.201300432 · Cited by 217
Zhang, J., Guy, M. J., Norman, H. S., Chen, Y.-C., Xu, Q., Dong, X., Guner, H., Wang, S., Kohmoto, T., Young, K. H., et al. (2011) · Journal of Proteome Research · doi:10.1021/pr200258m · Cited by 194
The continuing evolution of cardiac troponin I biomarker analysis: from protein to proteoform
Soetkamp, D., Raedschelders, K., Mastali, M., Sobhani, K., Bairey Merz, C. N., & Van Eyk, J. (2017) · Expert Review of Proteomics · doi:10.1080/14789450.2017.1387054 · Cited by 36
Metadata
- Authors
- Babuin, L., & Jaffe, A. S.
- Venue
- Canadian Medical Association Journal
- Publisher
- CMA Joule Inc.
- Published
- 2005-11-08
- Volume
- 173
- Issue
- 10
- Pages
- 1191-1202
- ISSN
- 0820-3946 (ISSN-L)
- 1488-2329
- OpenAlex
- W2045161311
- Cited by
- 686
- References
- 152
- FWCI
- 12.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Troponin: the biomarker of choice for the detection of cardiac injury. https://app.cochat.ai/papers/10.1503/cmaj.050141
- The paper
- Babuin, L., & Jaffe, A. S. (2005). Troponin: the biomarker of choice for the detection of cardiac injury. Canadian Medical Association Journal. https://doi.org/10.1503/cmaj.050141
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.