Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 217

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diagnostic Yield and Complications of Transbronchial Lung Cryobiopsy for Interstitial Lung Disease. A Systematic Review and Metaanalysis

Johannson, Kerri A., Marcoux, Veronica S., Ronksley, Paul E., Ryerson, Christopher J. · 2016 · Annals of the American Thoracic Society

Abstract

Rationale: The diagnostic usefulness and safety of transbronchial lung cryobiopsy for the evaluation of interstitial lung disease remain unclear. Objectives: This systematic review and metaanalysis aims to establish the diagnostic accuracy and yield of transbronchial cryobiopsy for interstitial lung diseases. Methods: We searched MedLine, EMBASE, Cochrane Central Register of Controlled Trials, and conference proceedings to identify studies assessing the diagnostic accuracy (compared with surgical biopsy) or yield of transbronchial lung cryobiopsy for interstitial lung disease (from database inception to January 2016). The diagnostic accuracy and yield were quantified and stratified by the method of diagnosis determination (histologic interpretation in isolation vs. incorporation within a multidisciplinary discussion). The frequency of procedure-related complications was also assessed from these reports. For full-text studies, random-effects models were used to calculate pooled estimates of diagnostic accuracy, yield, and complication frequency. Measurements and Main Results: Of 900 citations, 11 studies were selected for inclusion in this systematic review (7 full text, 4 abstracts). The selected studies reported on a total of 731 patients. No studies reported the diagnostic accuracy of transbronchial cryobiopsy. Diagnostic yield ranged from 74 to 98% when transbronchial cryobiopsy findings were interpreted in isolation, with a pooled estimate of 83% (95% confidence interval [CI], 73–94). Diagnostic yield ranged from 51 to 98% when transbronchial cryobiopsy was reviewed within a multidisciplinary discussion, with a pooled estimate of 79% (95% CI, 65–93). Pooled estimates for pneumothorax and moderate/severe bleeding were 12% (95% CI, 3–21) and 39% (95% CI, 3–76), respectively. Conclusions: The diagnostic accuracy of transbronchial lung cryobiopsy cannot be determined given the absence of studies directly comparing cryobiopsy diagnoses with diagnoses derived from surgical lung biopsies interpreted within multidisciplinary discussions. The histopathological and multidisciplinary discussion-based diagnostic yield of transbronchial cryobiopsy appears high, but with variable frequencies of complications dominated by pneumothorax and moderate-to-severe hemorrhage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1513/annalsats.201606-461sr

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 217

Metadata

Authors
Johannson, K. A., Marcoux, V. S., Ronksley, P. E., & Ryerson, C. J.
Venue
Annals of the American Thoracic Society
Published
2016-10-01
Volume
13
Issue
10
Pages
1828-1838
ISSN
  • 2325-6621 (ISSN-L)
  • 2329-6933
OpenAlex
W2501120166
Cited by
217
References
1
FWCI
6.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Yield and Complications of Transbronchial Lung Cryobiopsy for Interstitial Lung Disease. A Systematic Review and Metaanalysis. https://app.cochat.ai/papers/10.1513/annalsats.201606-461sr
The paper
Johannson, K. A., Marcoux, V. S., Ronksley, P. E., & Ryerson, C. J. (2016). Diagnostic Yield and Complications of Transbronchial Lung Cryobiopsy for Interstitial Lung Disease. A Systematic Review and Metaanalysis. Annals of the American Thoracic Society. https://doi.org/10.1513/annalsats.201606-461sr

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.