Cardiopulmonary Exercise Testing and Surgery
The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Abstract
The surgical patient population is increasingly elderly and comorbid and poses challenges to perioperative physicians. Accurate preoperative risk stratification is important to direct perioperative care. Reduced aerobic fitness is associated with increased postoperative morbidity and mortality. Cardiopulmonary exercise testing is an integrated and dynamic test that gives an objective measure of aerobic fitness or functional capacity and identifies the cause of exercise intolerance. Cardiopulmonary exercise testing provides an individualized estimate of patient risk that can be used to predict postoperative morbidity and mortality. This technology can therefore be used to inform collaborative decision-making and patient consent, to triage the patient to an appropriate perioperative care environment, to diagnose unexpected comorbidity, to optimize medical comorbidities preoperatively, and to direct individualized preoperative exercise programs. Functional capacity, evaluated as the anaerobic threshold and peak oxygen uptake (V.o2peak) predicts postoperative morbidity and mortality in the majority of surgical cohort studies. The ventilatory equivalents for carbon dioxide (an index of gas exchange efficiency), is predictive of surgical outcome in some cohorts. Prospective cohort studies are needed to improve the precision of risk estimates for different patient groups and to clarify the best combination of variables to predict outcome. Early data suggest that preoperative exercise training improves fitness, reduces the debilitating effects of neoadjuvant chemotherapy, and may improve clinical outcomes. Further research is required to identify the most effective type of training and the minimum duration required for a positive effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Clavien-Dindo Classification of Surgical Complications: Five-Year Experience
Clavien, P. A., Barkun, J., de Oliveira, M. L., Vauthey, J. N., Dindo, D., Schulick, R. D., de Santibañes, E., Pekolj, J., Slankamenac, K., Bassi, C., et al. (2009) · Annals of Surgery · doi:10.1097/sla.0b013e3181b13ca2 · Cited by 11,482
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Lee, T. H., Marcantonio, E. R., Mangione, C. M., Thomas, E. J., Polanczyk, C. A., Cook, E. F., Sugarbaker, D. J., Donaldson, M. C., Poss, R., Ho, K. K. L., et al. (1999) · Circulation · doi:10.1161/01.cir.100.10.1043 · Cited by 3,771
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
An estimation of the global volume of surgery: a modelling strategy based on available data
Weiser, T. G., Regenbogen, S. E., Thompson, K. D., Haynes, A. B., Lipsitz, S. R., Berry, W. R., & Gawande, A. A. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60878-8 · Cited by 2,511
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Khuri, S. F., Henderson, W. G., DePalma, R. G., Mosca, C., Healey, N. A., & Kumbhani, D. J. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000179621.33268.83 · Cited by 1,452
Fleisher, L. A., Fleischmann, K. E., Auerbach, A. D., Barnason, S. A., Beckman, J. A., Bozkurt, B., Davila-Roman, V. G., Gerhard-Herman, M. D., Holly, T. A., Kane, G. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.07.944 · Cited by 1,320
Physiologic Evaluation of the Patient With Lung Cancer Being Considered for Resectional Surgery
Brunelli, A., Kim, A. W., Berger, K. I., & Addrizzo-Harris, D. J. (2013) · Chest · doi:10.1378/chest.12-2395 · Cited by 910
Detecting the threshold of anaerobic metabolism in cardiac patients during exercise
Wasserman, K., & McIlroy, M. B. (1964) · The American Journal of Cardiology · doi:10.1016/0002-9149(64)90012-8 · Cited by 864
Cited by
The anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312
“The AT concept, as proposed 50 years ago by Karlman Wasserman and colleagues (Naimark et al. 1964; Wasserman & McIlroy, 1964), considered muscle anoxia/hypoxia as the progenitor of the increased muscle and blood [La−], termed ‘Owles’s point’ in 1930 (Owles, 1930).”
BackgroundMethodInfluentialPrehabilitation, enhanced recovery after surgery, or both? A narrative review
Gillis, C., Ljungqvist, O., & Carli, F. (2022) · British Journal of Anaesthesia · doi:10.1016/j.bja.2021.12.007 · Cited by 308
Practical guide to cardiopulmonary exercise testing in adults
Glaab, T., & Taube, C. (2022) · Respiratory Research · doi:10.1186/s12931-021-01895-6 · Cited by 229
“By combining several methods (so-called 3- panel view (panels 3, 4, 7 [original version: panels 5, 6, 9]), AT can be determined in most cases and excludes non-physiologic hyperventilation as the origin of the V-slope inflection point [12].”
MethodBrawner, C. A., Ehrman, J. K., Bole, S., Kerrigan, D. J., Parikh, S. S., Lewis, B. K., Gindi, R. M., Keteyian, C., Abdul-Nour, K., & Keteyian, S. J. (2021) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2020.10.003 · Cited by 185
Metadata
- Authors
- Older, P. O., & Levett, D. Z. H.
- Venue
- Annals of the American Thoracic Society
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-07-01
- Volume
- 14
- Issue
- Supplement_1
- Pages
- S74-S83
- ISSN
- 2325-6621 (ISSN-L)
- 2329-6933
- OpenAlex
- W2615671142
- Cited by
- 197
- References
- 88
- FWCI
- 43.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.