Bond Between Steel and Self-Compacting Concrete in Composite Tube Columns
Open accessAbstract
This paper presents research results of composite tubes filled with self-compacting concrete. The impact of the selected materials and geometric factors on resistance to the vertical shear was evaluated in this study. The resistance of the tested members was compared with recommendations given in Eurocode PN-EN 1994-1-1. From the results obtained in the tests it can be deduced that more parameters should be taken into consideration when determining resistance to the vertical shear in the interface between steel and concrete than PN-EN 1994- 1-1 recommends.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
During determining resistance to vertical shear in the interface, not only cross-section should be taken into account, but also its geometry, steel profile thickness, and concrete grade.
“The analysis shows that during determining the resistance to vertical shear in the interface, not only the crosssection should be taken into account, but also its geometry, steel profile thickness, as well as concrete grade.”
From Analysis of shrinkage influence on bond in CFST elements filled with SCC (2021) · cites this paper as Szadkowska and Szmigiera [16]
Cited by
Sorted by citations
Analysis of shrinkage influence on bond in CFST elements filled with SCC
Szadkowska, M., & Szmigiera, E. (2021) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2021.106824 · Cited by 17 · see citing works
Self-citation
- Authors
- Szadkowska, M., & Szmigiera, E.
- Affiliations
- Warsaw University of Technology (PL)
- Venue
- Archives of Civil Engineering
- Publisher
- Walter de Gruyter GmbH
- Published
- 2017-06-27
- Volume
- 63
- Issue
- 2
- Pages
- 131-143
- ISSN
- 1230-2945 (ISSN-L)
- OpenAlex
- W2752189844
- Cited by
- 4
- References
- 0
- Citations by year
- 2026: 1 · 2023: 2 · 2021: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Archives of Civil Engineering (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis
- Physical Sciences › Engineering › Building and Construction › Structural Behavior of Reinforced Concrete
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Materials Analysis
- Keywords
- self-compacting concrete, steel tubes, geometric parameters, design guidelines
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review