Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 230

The DOI matches its Crossref record.

A Simple, Versatile, Sensitive and Volume-Independent Method for Quantitative Protein Determination which is Independent of Other External Influences

NEUHOFF, Volker, PHILIPP, Klaus, ZIMMER, Hans-Georg, MESECKE, Senta · 1979 · Hoppe-Seyler´s Zeitschrift für physiologische Chemie

Abstract

A method is described which in principle is a quantitative "spot analysis". 0.5-5 microliter of a protein solution in the concentration range between 0.01-10 mg/ml is used for one determination. The sample is taken up by capillary attraction in a 0.5-, 1-, 2- or 5-microliters capillary and transferred to a cellulose acetate strip. The protein is fixed and stained simultaneously by dipping the cellulose acetate strip into a solution of Amido Black or a benzoxanthene derivative (Hoechst 2495) dissolved in in methanol/acetic acid. After elution of the excess of dye (3 x 5 min) the quantitative evaluation can be performed in different ways: 1) The sample is fixed and made transpartent by incubation in dioxane/1-butanol and evaluated densitometrically (Amido Black 10B) or 2) the evaluation is performed in situ by spot fluorometry (Hoechst 2495). 3 The sample can be dissolved together with the acetate layer completely in dioxane, dimethylsulfoxide or N,N-dimethylformamide and evaluated photometrically or 4) fluorometrically. 5) Highest sensitivity is reached if the fluorochrome (Hoechst 2495) bound to the protein is eluted with 15% NH4OH and measured fluorometrically. There is a linear correlation with a correlation coefficient of 0.999 between the fluorescence and a protein amount of 10 ng-20 micrograms. In addition to its simplicity, the method has the advantage of being independent of or well-defined against other external influences, e.g., sodium dodecyl sulfate, mercaptoethanol, Triton X-100, etc. The stainability of a protein with Amido Black is influenced stoichiometrically by sodium dodecyl sulfate (not by mercaptoethanol) whilst the staining with Hoechst 2495 is not at all affected. As there is linear correlation between the area of a spot on an acetate layer and the volume applied in the range between 0.5 and 5 microliters, (only influenced stoichiometrically by the protein concentration in that volume, which in turn is measured by staining with Amido Black), then with a simple iterative calculation on the basis of suitable calibration curves, it is easily possible to determine a protein concentration in mg/ml even in an unknown volume between 0.5 and 5 microliters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/bchm2.1979.360.2.1657

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
NEUHOFF, V., PHILIPP, K., ZIMMER, H.-G., & MESECKE, S.
Venue
Hoppe-Seyler´s Zeitschrift für physiologische Chemie
Published
1979-01
Volume
360
Issue
2
Pages
1657-1670
ISSN
0018-4888 (ISSN-L)
OpenAlex
W2312829343
Cited by
230
References
0
FWCI
3.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Simple, Versatile, Sensitive and Volume-Independent Method for Quantitative Protein Determination which is Independent of Other External Influences. https://app.cochat.ai/papers/10.1515/bchm2.1979.360.2.1657
The paper
NEUHOFF, V., PHILIPP, K., ZIMMER, H.-G., & MESECKE, S. (1979). A Simple, Versatile, Sensitive and Volume-Independent Method for Quantitative Protein Determination which is Independent of Other External Influences. Hoppe-Seyler´s Zeitschrift für physiologische Chemie. https://doi.org/10.1515/bchm2.1979.360.2.1657

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.