EEG-Based Communication: Evaluation of Alternative Signal Prediction Methods - EEG-basierte Kommunikation: Evaluierung alternativer Methoden zur Signalprädiktion
The DOI matches its Crossref record.
Abstract
Individuals can learn to control the amplitude of EEG activity in specific frequency bands over sensorimotor cortex and use it to move a cursor to a target on a computer screen. For one-dimensional (i.e., vertical) cursor movement, a linear equation translates the EEG activity into cursor movement. To translate an individual's EEG control into cursor control as effectively as possible, the intercept in this equation, which determines whether upward or downward movement occurs, should be set so that top and bottom targets are equally accessible. The present study compares alternative methods for using an individual's previous performance to select the intercept for subsequent trials. In offline analyses, five different intercept selection methods were applied to EEG data collected while trained subjects were moving the cursor to targets at the top or bottom edge of the screen. In the first two methods-moving average, and weighted sum-a single intercept was selected for the entire 1-2 sec period of each trial. In the other three methods-blocked moving average, blocked weighted sum, and blocked recursive sum (a variation of the weighted sum)-an intercept was selected for each 200-ms segment of the trial. The results from these methods were compared in regard to their balance between upward and downward movements and their consistency of performance across trials. For all subjects combined, the five methods performed similarly. However, performance across subjects was more consistent for the moving average, blocked moving average, and blocked recursive sum methods than for the weighted sum and blocked weighted sum methods. Due to its consistent performance and its computational simplicity, the moving average method, using the five most recent pairs of top and bottom trials, appears to be the method of choice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationControl of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Self-citationA brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Self-citationToward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Metadata
- Authors
- Ramoser, H., Wolpaw, J. R., & Pfurtscheller, G.
- Venue
- Biomedizinische Technik/Biomedical Engineering
- Publisher
- Walter de Gruyter GmbH
- Published
- 1997
- Volume
- 42
- Issue
- 9
- Pages
- 226-233
- ISSN
- 0013-5585 (ISSN-L)
- 1862-278X
- OpenAlex
- W2047894695
- Cited by
- 45
- References
- 0
- FWCI
- 0.89
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EEG-Based Communication: Evaluation of Alternative Signal Prediction Methods - EEG-basierte Kommunikation: Evaluierung alternativer Methoden zur Signalprädiktion. https://app.cochat.ai/papers/10.1515/bmte.1997.42.9.226
- The paper
- Ramoser, H., Wolpaw, J. R., & Pfurtscheller, G. (1997). EEG-Based Communication: Evaluation of Alternative Signal Prediction Methods - EEG-basierte Kommunikation: Evaluierung alternativer Methoden zur Signalprädiktion. Biomedizinische Technik/Biomedical Engineering. https://doi.org/10.1515/bmte.1997.42.9.226
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.