A pragmatic proposal for permissible limits in external quality assessment schemes with a compromise between biological variation and the state of the art
The DOI matches its Crossref record.
Abstract
Permissible limits for internal and external quality assurance are either based on biological variation or on the state of the art (technical feasibility). The former approach has a scientific basis, but, in some cases, leads to limits which are either not achievable under the present technology, or which are not stringent enough. If proficiency testing is mandatory, stringent limits which cannot be fulfilled by the majority of laboratories could lead to juristic consequences. Therefore, most national guidelines were based on the state of the art, however, without providing the underlying reasoning. A simple algorithm for permissible limits in external quality assessment schemes (EQAS) is proposed based on biological variation, technical feasibility and correlated to the rate of false positive results. The proposed limits are compared with some limits from several EQAS (RiliBÄK, SEKK, RCPA, CLIA, PROLARIT). The suggested limits are slightly more stringent than the German RiliBÄK, less stringent than the Australasian guidelines and agreed best with the Czech SEKK and the Italian PROLARIT scheme. The graphical presentation of permissible limits strictly derived of biological variation with the proposed limits led to straight lines with different slopes and a cross-over at the limits for quantities with a medium biological variation (e.g., trijodthyronine). The greatest discordance between the various recommendations was observed for calcium, chloride, hemoglobin A
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Thus, if EQA providers recalculate their APSs based on new and tighter data, it will be more dif fi cult for participating laboratories to satisfy the new APS [4, 5].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [5]
Citations
Cited by
The European Biological Variation Study (EuBIVAS): a summary report
Carobene, A., Aarsand, A. K., Bartlett, W. A., Coskun, A., Diaz-Garzon, J., Fernandez-Calle, P., Guerra, E., Jonker, N., Locatelli, M., Plebani, M., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0370 · Cited by 84
“Thus, if EQAproviders recalculate their APSs based onnewand tighter data, it will bemore difficult for participating laboratories to satisfy the new APS [4, 5].”
BackgroundMethodSelf-citationBiological variation estimates of Alzheimer's disease plasma biomarkers in healthy individuals
Brum, W. S., Ashton, N. J., Simrén, J., di Molfetta, G., Karikari, T. K., Benedet, A. L., Zimmer, E. R., Lantero‐Rodriguez, J., Montoliu‐Gaya, L., Jeromin, A., et al. (2024) · Alzheimer's & Dementia · doi:10.1002/alz.13518 · Cited by 76
“0) Smokers, n (%) 1 (10) 0 1 (5) Physical exercise, n (%) 8 (80) 5 (50) 13 (65) No physical exercise 2 (20) 5 (50) 7 (35) < 3h per week 1 (10) 1 (10) 2 (10) ≥ 3 7 (70) 4 (40) 11 (55) Study center, n (%) Italy (Milan) 2 (20) 2 (20) 4 (20) Italy (Padua) 3 (30) 0 3 (15) Netherlands 3 (30) 2 (20) 5 (25) Norway 2 (20) 3 (3…”
Self-citationExternal quality assessment programs in the context of ISO 15189 accreditation
Sciacovelli, L., Secchiero, S., Padoan, A., & Plebani, M. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1179 · Cited by 72
Coskun, A., Braga, F., Carobene, A., Tejedor Ganduxe, X., Aarsand, A. K., Fernández-Calle, P., Díaz-Garzón Marco, J., Bartlett, W., Jonker, N., Aslan, B., et al. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0658 · Cited by 56
“However, it is generally agreed that analytical quality should be compared against objective APSs, considering that models 1 or 2 are preferred [7, 8].”
BackgroundSelf-citationPermissible limits for uncertainty of measurement in laboratory medicine
Haeckel, R., Wosniok, W., Gurr, E., et al. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0874 · Cited by 55
Self-citation
Metadata
- Authors
- Haeckel, R., Wosniok, W., Kratochvila, J., & Carobene, A.
- Affiliations
- University of Bremen (DE)
- IRCCS Ospedale San Raffaele (IT)
- Corresponding author
- Haeckel, Rainer
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2012-05-01
- Volume
- 50
- Issue
- 5
- Pages
- 833-9
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2324336557
- Cited by
- 33
- References
- 0
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 5 · 2023: 6 · 2022: 1 · 2021: 5 · 2020: 1 · 2019: 2 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 3 · 2014: 1
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- permissible limits, proficiency testing, biological variation, state of the art, technical feasibility, false positives, laboratory quality assurance, reference values, CLIA, HbA1c, calcium, chloride, sodium, triiodothyronine
- MeSH terms
- Humans, Quality Control, Statistics as Topic, Clinical Laboratory Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.