Complete blood count reference intervals and age- and sex-related trends of North China Han population
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Defining common reference intervals (RIs) are encouraging. The aim of this study is to establish RIs for complete blood count (CBC) in a Chinese Han population and probe their age- and sex-related CBC trends. Additionally, we will compare the CBC RIs of Han with those of other races. METHODS: In total 1259 Han individuals (584 male and 675 female) were recruited in North China. CBC was processed on Sysmex XE-2100, Coulter LH750 and Mindray BC5800 whose traceability was well verified. The non-parametric 2.5th-97.5th percentiles RIs were calculated. RESULTS: The RIs for CBC parameters did not show apparent analyzer-specificity, apart from mean cellular volume (MCV), mean platelet volume (MPV), plateletcrit (PCT) and platelet distribution width (PDW). Red blood cell (RBC), hemoglobin (HBG), hematocrit (HCT), mean cellular hemoglobin (MCH), and mean cellular hemoglobin concentration (MGHC) are higher in males; and their male mean values tend to drop after 40 years; conversely, the female mean values tend to rise. Platelet (PLT) is higher in females and tends to drop after 40 years in both sexes. White blood cell (WBC) and absolute count of neutrophils (NE) and monocytes (MO) are higher in males, but there is no apparent change with age. Lymphocytes (LY) absolute count declines with age in males, but the same change in females is not obvious. RIs for HBG and HCT are similar among Han, Nordic, US European and US Mexican populations and are lower in US Africans. WBC RIs for Han and US African populations are lower than that for US Europeans and US Mexicans. CONCLUSIONS: RIs for major blood cell parameters are not method-dependent; variations obviously exist in age, sex and race. Consequently, common RIs for most CBC parameters appear inapplicable.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, previous studies using features from other domains were conducted on relatively small sample sets, prone to over-fitting and lack of validation in large-scale populations with synthetic heterogeneity14,33–35,57,58.”
From Optimizing multi-domain hematologic biomarkers and clinical features for the differential diagnosis of unipolar depression and bipolar depression (2023) · doi:10.1038/s44184-023-00024-z · cites this paper as [57]
Citations
Cites
Automated Blood Cell Counts: State of the Art
Buttarello, M., & Plebani, M. (2008) · American Journal of Clinical Pathology · doi:10.1309/ek3c7ctdknvpxvtn · Cited by 355
Low Testosterone Levels and the Risk of Anemia in Older Men and Women
Ferrucci, L., Maggio, M., Bandinelli, S., Basaria, S., Lauretani, F., Ble, A., Valenti, G., Ershler, W. B., Guralnik, J. M., & Longo, D. L. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.13.1380 · Cited by 272
The role of red blood cell distribution width in cardiovascular and thrombotic disorders
Montagnana, M., Cervellin, G., Meschi, T., & Lippi, G. (2012) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.831 · Cited by 271
The IFCC recommendation on estimation of reference intervals. The RefVal Program
Solberg, H. E. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.121 · Cited by 258 · cited 1×
“5th percentile RIs [10] were calculated for all parameters on each analyzer.”
MethodProinflammatory state and circulating erythropoietin in persons with and without anemia
Ferrucci, L., Guralnik, J. M., Woodman, R. C., Bandinelli, S., Lauretani, F., Corsi, A. M., Chaves, P. H. M., Ershler, W. B., & Longo, D. L. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.06.039 · Cited by 240
Cheng, C. K.-W., Chan, J., Cembrowski, G. S., & Assendelft, O. W. V. (2004) · Laboratory Hematology · doi:10.1532/lh96.04010 · Cited by 222
Reference intervals: the way forward
Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008170 · Cited by 199 · cited 2×
“Desired common RIs study contributes to better understanding of the various sources of population variability [2, 12].”
BackgroundMethodPlatelet Counting by the RBC/Platelet Ratio Method
International Council for Standardization in Haematology Expert Panel on Cytometry International Society of Laboratory Hematology Task Force on Platelet Counting (2001) · American Journal of Clinical Pathology · doi:10.1309/w612-myep-fa7u-8uya · Cited by 157
Race‐specific WBC and neutrophil count reference intervals
LIM, E. ‐., CEMBROWSKI, G., CEMBROWSKI, M., & CLARKE, G. (2010) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2010.01223.x · Cited by 93
den Bossche, J. V., Devreese, K. M. J., Malfait, R., Vyvere, M. V. D., Wauters, A., Neels, H., & Schouwer, P. D. (2002) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2002.014 · Cited by 85
Research works printed but not linked: 22
- ICSH, 2001, Panel Recommendation for reference method for packed cell volume Laboratory, Cytometry Hematology, 148
- ICSH, 2001, Panel Recommendation for reference method for packed cell volume Laboratory, Cytometry Hematology, 148
- ICSH, 1994, Reference method for the enumeration of erythrocytes and leukocytes, Clin Lab Haematol, 16, 13
- ICSH, 1996, HGB Expert Panel Recommendations for reference method for haemoglobinometry in human blood and specifications for international haemiglobincyanide standard, J Clin Pathol, 49
- Ceriotti, 2009, Reference intervals the way forward, Ann Clin Biochem, 46, 8, 10.1258/acb.2008.008170 · DOI · Paper page
- Ferrucci, 2005, Proinflammatory state and circulating erythropoietin in persons with and without anemia, AM Am J Med, 1288
- Wakeman, 2007, Robust routine haematology reference ranges for healthy adults, Int J Lab Hematol, 29, 279, 10.1111/j.1365-2257.2006.00883.x · DOI
- Nordic, 2012, Reference Interval Project data Available from http pweb furst no norip Accessed, Hematology, 21
- Shelton, 2012, Androgen deficiency in aging and metabolically challenged men, Clin Am, 39
- ICSH, 1994, Reference method for the enumeration of erythrocytes and leukocytes, Clin Lab Haematol, 16, 13
- ICSH, 2001, Panel Platelet counting by RBC platelet ratio method, Cytometry Am J Clin Pathol, 115
- Solberg HE, 2004, The IFCC recommendation on estimation of reference intervals The program, Clin Chem Lab Med, 710
- Cheng, 2004, OW Complete blood count reference interval diagrams derived from NHANES III : stratification by age sex race, Lab, 10
- Buttarello, 2008, Automated blood cell count State of the Art, Am J Clin Pathol, 16, 130
- Ceriotti, 2009, Common reference intervals the position, Clin Biochem, 297, 10.1016/j.clinbiochem.2008.09.017 · DOI
- Montagnana, 2011, The role of red blood cell distribution width in cardiovascular and thrombotic disorders, Clin Chem Lab Med, 635
- Brummitt, 2000, DR The determination of a reference range for new platelet parameters produced by the Bayer full blood count analyser, Clin Lab Haematol, 22, 120, 10.1046/j.1365-2257.2000.00285.x · DOI
- Nordic, 2012, Reference Interval Project data Available from http pweb furst no norip Accessed, Hematology, 21
- ICSH, 1996, HGB Expert Panel Recommendations for reference method for haemoglobinometry in human blood and specifications for international haemiglobincyanide standard, J Clin Pathol, 49
- Lim, 2010, EM specific neutrophil count reference intervals, Race Int J Lab Hematol, 590, 10.1111/j.1751-553X.2010.01223.x · DOI · Paper page
- Van, 2002, den de Reference intervals for a complete blood count determined on different automated haematology analysers, Gen Cell Clin Chem Lab Med, 120
- Van, 2002, den de Reference intervals for a complete blood count determined on different automated haematology analysers, Gen Cell Clin Chem Lab Med, 120
Cited by
Red blood cell distribution width: A simple parameter with multiple clinical applications
Salvagno, G. L., Sanchis-Gomar, F., Picanza, A., & Lippi, G. (2015) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2014.992064 · Cited by 1,236
C‐reactive protein correlates with computed tomographic findings and predicts severe COVID‐19 early
Tan, C., Huang, Y., Shi, F., Tan, K., Ma, Q., Chen, Y., Jiang, X., & Li, X. (2020) · Journal of Medical Virology · doi:10.1002/jmv.25871 · Cited by 565
He, Q., Su, G., Liu, K., Zhang, F., Jiang, Y., Gao, J., Liu, L., Jiang, Z., Jin, M., & Xie, H. (2017) · PLOS ONE · doi:10.1371/journal.pone.0189837 · Cited by 163
Hoffmann, J. J. M. L., Nabbe, K. C., & van den Broek, N. M. A. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0155 · Cited by 156
Diagnostic and prognostic value of red blood cell distribution width in sepsis: A narrative review
Hu, Z.-D., Lippi, G., & Montagnana, M. (2020) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2020.01.001 · Cited by 131
Metadata
- Authors
- Qiao, R., Yang, S., Yao, B., Wang, H., Zhang, J., & Shang, H.
- Affiliations
- Peking University Third Hospital (CN)
- First Hospital of China Medical University (CN)
- Corresponding author
- Zhang, Jie
- Shang, Hong
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2014-01-01
- Volume
- 52
- Issue
- 7
- Pages
- 1025-32
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2074218434
- Cited by
- 64
- References
- 16
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 4 · 2023: 10 · 2022: 7 · 2021: 6 · 2020: 5 · 2019: 7 · 2018: 4 · 2017: 3 · 2016: 6 · 2015: 2 · 2014: 3
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Oncology › Inflammatory Biomarkers in Disease Prognosis
- Health Sciences › Medicine › Hematology › Iron Metabolism and Disorders
- Keywords
- complete blood count, reference values, age trends, sex differences, Han Chinese, hematological parameters, hemoglobin, hematocrit, white blood cell count, platelet count
- MeSH terms
- Adult, Age Factors, Aged, Blood Cell Count, China, Ethnicity, Female, Humans, Male, Middle Aged, Reference Values, Sex Factors, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complete blood count reference intervals and age- and sex-related trends of North China Han population. https://app.cochat.ai/papers/10.1515/cclm-2012-0486
- The paper
- Qiao, R., Yang, S., Yao, B., Wang, H., Zhang, J., & Shang, H. (2014). Complete blood count reference intervals and age- and sex-related trends of North China Han population. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2012-0486
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.