The 3rd International Standard for serum IgE: international collaborative study to evaluate a candidate preparation
The DOI matches its Crossref record.
Abstract
BACKGROUND: The measurement of serum IgE aids in the diagnosis and management of atopic allergic disease and hyper-IgE immunodeficiency syndromes. The 2nd World Health Organization (WHO) International Reference Reagent (IRR) for serum IgE (75/502; 5000 IU/ampoule), is widely used to calibrate assays for serum IgE. Exhaustion of stocks of the 2nd IRR necessitated the production of a replacement preparation and its evaluation in an international collaborative study to determine its suitability to serve as the 3rd International Standard (IS) for serum IgE. METHODS: Sera and defibrinated plasma with elevated IgE levels were pooled and lyophilised in ampoules. This preparation, coded 11/234, was assayed by 18 laboratories in 11 countries using commercial assay methodology for IgE, along with the 2nd IRR, 75/502, and two lyophilised serum samples. RESULTS: Overall, there were no consistent differences in the way that the candidate IS (11/234), the IRR (75/502), and the two serum samples behaved in the assays with respect to linearity and parallelism. The mean IgE value of the candidate IS, 11/234, relative to the IRR, 75/502, was 13,411 IU/mL based on parallel line analysis of raw assay data at NIBSC, and 13,551 IU/mL based on the laboratories' own estimates after correcting for the values obtained for 75/502. CONCLUSIONS: The use of 11/234 will ensure that assays for serum IgE continue to be well standardised. The preparation was established by the WHO Expert Committee on Biological Standardization as the 3rd IS for serum IgE with an assigned value of 13,500 IU/mL, corresponding to 6750 IU/ampoule.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EAACI Molecular Allergology User's Guide
Matricardi, P. M., Kleine‐Tebbe, J., Hoffmann, H. J., Valenta, R., Hilger, C., Hofmaier, S., Aalberse, R. C., Agache, I., Asero, R., Ballmer‐Weber, B., et al. (2016) · Pediatric Allergy and Immunology · doi:10.1111/pai.12563 · Cited by 932
“The total serum IgE ‘heterologous’ calibration system that is used in all regulatory cleared singleplex assays is traceable to the World Health Organization’s recently depleted 75/502 and currently used third 11/234 human IgE Reference Preparations (71).”
MethodAnsotegui, I. J., Melioli, G., Canonica, G. W., Caraballo, L., Villa, E., Ebisawa, M., Passalacqua, G., Savi, E., Ebo, D., Gómez, R. M., et al. (2020) · World Allergy Organization Journal · doi:10.1016/j.waojou.2019.100080 · Cited by 489
EAACI Molecular Allergology User's Guide 2.0
Dramburg, S., Hilger, C., Santos, A. F., de las Vecillas, L., Aalberse, R. C., Acevedo, N., Aglas, L., Altmann, F., Arruda, K. L., Asero, R., et al. (2023) · Pediatric Allergy and Immunology · doi:10.1111/pai.13854 · Cited by 298
Fox, B. J., Hockley, J., Rigsby, P., Dolman, C., Meroni, P. L., & Rönnelid, J. (2019) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2019-215845 · Cited by 24
Self-citation
Metadata
- Authors
- Thorpe, S. J., Heath, A., Fox, B., Patel, D., & Egner, W.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2014-01-01
- Volume
- 52
- Issue
- 9
- Pages
- 1283-9
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2329261251
- Cited by
- 39
- References
- 0
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.