Cardiac troponin assays: a review of quantitative point-of-care devices and their efficacy in the diagnosis of myocardial infarction
Open accessThe DOI matches its Crossref record.
Abstract
Cardiac troponin (cTn) I and T are released from myocardial cells following necrosis, i.e., cell death. An accurate measure of cTn concentrations in a patient’s blood following ischemia/chest pain can enable providers to determine whether or not a myocardial infarction (MI) has occurred. Point-of-care (POC) devices that measure blood cTn concentrations in under 30 min may help to significantly reduce hospital costs by managing and triaging patients out of the emergency department as quickly as possible. The use of POC devices that measure cTnI and cTnT with a coefficient of variation (CV) ≤20% at the 99th percentile upper reference limit (URL) limits both false positive and negative results and provides clinically acceptable findings to assist in appropriate diagnoses. This article reviews nine POC devices that measure cTn in terms of their clinical sensitivity and specificity, analytical imprecision, sample type and preparation, and each assay’s principle of analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardiac troponins: from myocardial infarction to chronic disease
Park, K. C., Gaze, D. C., Collinson, P. O., & Marber, M. S. (2017) · Cardiovascular Research · doi:10.1093/cvr/cvx183 · Cited by 510
Apple, F. S., Sandoval, Y., Jaffe, A. S., & Ordonez-Llanos, J. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.255109 · Cited by 408
Self-citationFlorkowski, C., Don-Wauchope, A., Gimenez, N., Rodriguez-Capote, K., Wils, J., & Zemlin, A. (2017) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2017.1399336 · Cited by 189
Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I
Boeddinghaus, J., Nestelberger, T., Koechlin, L., Wussler, D., Lopez-Ayala, P., Walter, J. E., Troester, V., Ratmann, P. D., Seidel, F., Zimmermann, T., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.12.065 · Cited by 171
“Previous MI 280 (22) 71 (40) 209 (19) <0.”
BackgroundSarangadharan, I., Regmi, A., Chen, Y.-W., Hsu, C.-P., Chen, P.-C., Chang, W.-H., Lee, G.-Y., Chyi, J.-I., Shiesh, S.-C., Lee, G.-B., et al. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.09.018 · Cited by 169
“3(b) is used to estimate the unknown troponin I concentration in serum to be 2.62 pg/mL, which is lower than the LOD for almost all the existing commercial assays (Tate et al., 2012; Amundson Beret and Apple Fred, 2015).”
MethodInfluential
Metadata
- Authors
- Amundson, B. E., & Apple, F. S.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2015-01-01
- Volume
- 53
- Issue
- 5
- Pages
- 665-76
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W1986382255
- Cited by
- 75
- References
- 0
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac troponin assays: a review of quantitative point-of-care devices and their efficacy in the diagnosis of myocardial infarction. https://app.cochat.ai/papers/10.1515/cclm-2014-0837
- The paper
- Amundson, B. E., & Apple, F. S. (2015). Cardiac troponin assays: a review of quantitative point-of-care devices and their efficacy in the diagnosis of myocardial infarction. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2014-0837
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.