Smart management of sample dilution using an artificial neural network to achieve streamlined processes and saving resources: the automated nephelometric testing of serum free light chain as case study
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background: Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. Methods: An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. Results: The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a “rational” dilution scheme based on a 4-step dilution. Conclusions: Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The implementation of MLP-ANN resulted in a remarkable reduction in wasted tests for κ-FLC and λ-FLC, with reductions of 69.4 and 70.8 %, respectively.”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [29]
Citations
Cites
Machine learning: a review of classification and combining techniques
Kotsiantis, S. B., Zaharakis, I. D., & Pintelas, P. E. (2006) · Artificial Intelligence Review · doi:10.1007/s10462-007-9052-3 · Cited by 1,582
Interpreting neural-network connection weights
Garson, G. D. (1991) · AI Expert archive · doi:10.5555/129449.129452 · Cited by 1,472
Errors in laboratory medicine and patient safety: the road ahead
Plebani, M. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.170 · Cited by 153
Quantitative serum free light chain assay--analytical issues.
Tate, J. R., Bazeley, S., Sykes, S., & Mollee, P. N. (2009) · PubMed · Cited by 103
Serum free light chains in clinical laboratory diagnostics
Jenner, E. L. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.08.018 · Cited by 92
Serum-free light-chain assay: clinical utility and limitations
Bhole, M. V., Sadler, R., & Ramasamy, K. (2014) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563213518758 · Cited by 80
The “hospital central laboratory”: automation, integration and clinical usefulness
Zaninotto, M., & Plebani, M. (2010) · cclm · doi:10.1515/cclm.2010.192 · Cited by 77
Sárközi, L., Simson, E., & Ramanathan, L. V. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00020-2 · Cited by 70
Clinical laboratories: production industry or medical services?
Plebani, M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1007 · Cited by 50
Abadie, J. M., van Hoeven, K. H., & Wells, J. M. (2009) · American Journal of Clinical Pathology · doi:10.1309/ajcpr2m4euynhlgm · Cited by 49
Pretorius, C. J., Klingberg, S. L., Tate, J. R., Wilgen, U., & Ungerer, J. P. J. (2012) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2012.011264 · Cited by 49
Statistical efficiency of adaptive algorithms
Widrow, B. C., & Kamenetsky, M. (2003) · Neural Networks · doi:10.1016/s0893-6080(03)00126-6 · Cited by 33
Calculating cost savings in utilization management
MacMillan, D. H. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.09.024 · Cited by 23
Streitberg, G. S., Angel, L., Sikaris, K. A., & Bwititi, P. (2012) · SLAS TECHNOLOGY · doi:10.1177/2211068212448865 · Cited by 20
Ialongo, C., Pieri, M., & Bernardini, S. (2016) · SLAS TECHNOLOGY · doi:10.1177/2211068216636635 · Cited by 18
Self-citationMussap, M. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.09.034 · Cited by 8
Cited by
Machine learning-based clinical decision support using laboratory data
Çubukçu, H. C., Topcu, D. İ., & Yenice, S. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1037 · Cited by 66
Evaluation of a new free light chain ELISA assay: bringing coherence with electrophoretic methods
Jacobs, J. F. M., Angelino, C. M. D. K., Brouwers, H. M. L. M., Croockewit, S., Joosten, I., & Molen, R. G. V. D. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0339 · Cited by 34
Advancing Laboratory Medicine Practice With Machine Learning: Swift yet Exact
You, J., Seok, H. S., Kim, S., & Shin, H. (2024) · Annals of Laboratory Medicine · doi:10.3343/alm.2024.0354 · Cited by 28
Ialongo, C., & Bernardini, S. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0226 · Cited by 9
Self-citationThe role of AI in pre-analytical phase – use cases
Çubukçu, H. C. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1220 · Cited by 6
Metadata
- Authors
- Ialongo, C., Pieri, M., & Bernardini, S.
- Affiliations
- University of Rome Tor Vergata (IT)
- Corresponding author
- Ialongo, Cristiano
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2016-07-12
- Volume
- 55
- Issue
- 2
- Pages
- 231-236
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2467734416
- Cited by
- 10
- References
- 16
- Citations by year
- 2025: 3 · 2024: 2 · 2023: 1 · 2021: 1 · 2019: 2 · 2017: 1
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Cineca Institutional Research Information System (Tor Vergata University) (submittedVersion)
- IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Physical Sciences › Materials Science › Materials Chemistry › Machine Learning in Materials Science
- Keywords
- free light chains, sample dilution, artificial neural networks, multilayer perceptron, nephelometry, kappa free light chains, automated analyzers, laboratory information systems
- MeSH terms
- Automation, Humans, Immunoglobulin Light Chains, Indicator Dilution Techniques, Nephelometry and Turbidimetry, Neural Networks, Computer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.