Harmonisation of serum dihydrotestosterone analysis: establishment of an external quality assurance program
Abstract
BACKGROUND: Serum dihydrotestosterone (DHT) is an important analyte for the clinical assessment of disorders of sex development. It is also reportedly a difficult analyte to measure. Currently, there are significant gaps in the standardisation of this analyte, including no external quality assurance (EQA) program available worldwide to allow for peer review performance of DHT. We therefore proposed to establish a pilot EQA program for serum DHT. METHODS: DHT was assessed in the 2015 Royal College of Pathologists of Australasia Quality Assurance Programs' Endocrine program material. The material's target (i.e. "true") values were established using a measurement procedure based on isotope dilution gas chromatography (GC) tandem mass spectrometry (MS/MS). DHT calibrator values were based on weighed values of pure DHT material (>97.5% purity) from Sigma. The allowable limits of performance (ALP) were established as ±0.1 up to 0.5 nmol/L and ±15% for targets >0.5 nmol/L. RESULTS: Target values for the six levels of RCPAQAP material for DHT ranged from 0.02 to 0.43 nmol/L (0.01-0.12 ng/mL). The material demonstrated linearity across the six levels. There were seven participating laboratories for this pilot study. Results of the liquid chromatography (LC) MS/MS methods were within the ALP; whereas the results from the immunoassay methods were consistently higher than the target values and outside the ALP. CONCLUSIONS: This report provides the first peer comparison of serum DHT measured by mass spectrometry (MS) and immunoassay laboratories. Establishment of this program provides one of the pillars to achieve method harmonisation. This supports accurate clinical decisions where DHT measurement is required.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In combination with MS as the detection method, GC-MS presents a robust analytical tool, unsurpassed in determining simultaneously a multitude of steroids including precursors or metabolites of progestins, glucocorticoids, mineralocorticoids, androgens and estrogens.
“In combination with MS as the detection method, GC-MS presents a robust analytical tool, unsurpassed in determining simultaneously a multitude of steroids including precursors or metabolites of progestins, glucocorticoids, mineralocorticoids (all C21-steroids), androgens (C19-steroids) and estrogens (C18steroids) (289,290).”
From Congenital Adrenal Hyperplasia—Current Insights in Pathophysiology, Diagnostics, and Management (2022) · cites this paper as [290]
The citation lists haven’t been fetched yet
References 25 · Cited by 12
- Authors
- Greaves, R. F., Jolly, L., Hartmann, M. F., Ho, C. S., Kam, R. K. T., Joseph, J., Boyder, C., & Wudy, S. A.
- Affiliations
- Murdoch Children's Research Institute (AU)
- Royal College of Pathologists of Australasia (AU)
- Justus-Liebig-Universität Gießen (DE)
- Chinese University of Hong Kong (HK)
- Pathwest Laboratory Medicine (AU)
- Corresponding author
- Greaves, Ronda F.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2017-01-01
- Volume
- 55
- Issue
- 4
- Pages
- 522-529
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2514135703
- Cited by
- 12
- References
- 25
- Citations by year
- 2026: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2019: 1 · 2018: 2 · 2017: 3 · 2016: 1
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- RMIT Research Repository (RMIT University Library) (submittedVersion)
- Figshare (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Sexual Differentiation and Disorders
- Keywords
- external quality assurance, method harmonization, disorders of sex development, immunoassay comparison, reference materials
- MeSH terms
- Calibration, Chromatography, Liquid, Enzyme-Linked Immunosorbent Assay, Humans, Immunoassay, Indicator Dilution Techniques, Gas Chromatography-Mass Spectrometry, Pilot Projects, Quality Control, Radioimmunoassay, Dihydrotestosterone, Tandem Mass Spectrometry, Laboratory Proficiency Testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review