Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Using machine learning to identify clotted specimens in coagulation testing

Fang, Kui, Dong, Zheqing, Chen, Xiling, Zhu, Ji, Zhang, Bing, You, Jinbiao, Xiao, Yingjun, Xia, Wenjin · 2021 · Clinical Chemistry and Laboratory Medicine (CCLM)

Abstract

Objectives: A sample with a blood clot may produce an inaccurate outcome in coagulation testing, which may mislead clinicians into making improper clinical decisions. Currently, there is no efficient method to automatically detect clots. This study demonstrates the feasibility of utilizing machine learning (ML) to identify clotted specimens. Methods: The results of coagulation testing with 192 clotted samples and 2,889 no-clot-detected (NCD) samples were retrospectively retrieved from a laboratory information system to form the training dataset and testing dataset. Standard and momentum backpropagation neural networks (BPNNs) were trained and validated using the training dataset with a five-fold cross-validation method. The predictive performances of the models were then assessed based on the testing dataset. Results: Our results demonstrated that there were intrinsic distinctions between the clotted and NCD specimens regarding differences in the testing results and the separation of the groups (clotted and NCD) in the t-SNE analysis. The standard and momentum BPNNs could identify the sample status (clotted and NCD) with areas under the ROC curves of 0.966 (95% CI, 0.958–0.974) and 0.971 (95% CI, 0.9641–0.9784), respectively. Conclusions: Here, we have described the application of ML algorithms in identifying the sample status based on the results of coagulation testing. This approach provides a proof-of-concept application of ML algorithms to evaluate the sample quality, and it has the potential to facilitate clinical laboratory automation.

Overview

Integrity signals

Registry

Crossref · 10.1515/cclm-2021-0081

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 33 references

Cited by

See all 29

Metadata

Authors
Fang, K., Dong, Z., Chen, X., Zhu, J., Zhang, B., You, J., Xiao, Y., & Xia, W.
Affiliations
Zhejiang Chinese Medical University (CN)
Corresponding author
Dong, Zheqing
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2021-03-03
Volume
59
Issue
7
Pages
1289-1297
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W3135593119
Cited by
29
References
33
Citations by year
2026: 1 · 2025: 9 · 2024: 4 · 2023: 9 · 2022: 5 · 2021: 1
FWCI
3.00
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
  • PubMed (publishedVersion)
Funders
Department of Health of Zhejiang Province (2021KY845)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
  • Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
Keywords
coagulation tests, sample quality assessment, BP neural network, laboratory automation
MeSH terms
Machine Learning, Noncommunicable Diseases, Laboratories, Clinical, Algorithms, Blood Coagulation Tests, Humans, Retrospective Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Using machine learning to identify clotted specimens in coagulation testing. https://app.cochat.ai/papers/10.1515/cclm-2021-0081
The paper
Fang, K., Dong, Z., Chen, X., Zhu, J., Zhang, B., You, J., Xiao, Y., & Xia, W. (2021). Using machine learning to identify clotted specimens in coagulation testing. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2021-0081

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.