CoChat

Decision support or autonomous artificial intelligence? The case of wrong blood in tube errors

Farrell, Christopher-John L. · 2022 · Clinical Chemistry and Laboratory Medicine (CCLM)

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Objectives: Artificial intelligence (AI) models are increasingly being developed for clinical chemistry applications, however, it is not understood whether human interaction with the models, which may occur once they are implemented, improves or worsens their performance. This study examined the effect of human supervision on an artificial neural network trained to identify wrong blood in tube (WBIT) errors. Methods: De-identified patient data for current and previous (within seven days) electrolytes, urea and creatinine (EUC) results were used in the computer simulation of WBIT errors at a rate of 50%. Laboratory staff volunteers reviewed the AI model’s predictions, and the EUC results on which they were based, before making a final decision regarding the presence or absence of a WBIT error. The performance of this approach was compared to the performance of the AI model operating without human supervision. Results: Laboratory staff supervised the classification of 510 sets of EUC results. This workflow identified WBIT errors with an accuracy of 81.2%, sensitivity of 73.7% and specificity of 88.6%. However, the AI model classifying these samples autonomously was superior on all metrics (p-values<0.05), including accuracy (92.5%), sensitivity (90.6%) and specificity (94.5%). Conclusions: Human interaction with AI models can significantly alter their performance. For computationally complex tasks such as WBIT error identification, best performance may be achieved by autonomously functioning AI models.

Overview

Integrity signals

Registry

Crossref · 10.1515/cclm-2021-0873

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 11 references

Cited by

See all 14

Metadata

Authors
Farrell, C.-J. L.
Affiliations
NSW Health Pathology (AU)
Corresponding author
Farrell, Christopher-John L.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2021-11-01
Volume
60
Issue
12
Pages
1993-1997
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W3209124605
Cited by
12
References
11
Citations by year
2025: 5 · 2024: 3 · 2023: 3 · 2022: 1
FWCI
1.10
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
Keywords
artificial intelligence, artificial neural networks, human oversight, human-AI interaction, autonomous AI systems, laboratory quality control, clinical decision support, error detection
MeSH terms
Artificial Intelligence, Computer Simulation, Humans, Neural Networks, Computer

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Decision support or autonomous artificial intelligence? The case of wrong blood in tube errors. https://app.cochat.ai/papers/10.1515/cclm-2021-0873
The paper
Farrell, C.-J. L. (2022). Decision support or autonomous artificial intelligence? The case of wrong blood in tube errors. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2021-0873

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.