Searching for the urine osmolality surrogate: an automated machine learning approach
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Objectives: Automated machine learning (AutoML) tools can help clinical laboratory professionals to develop machine learning models. The objective of this study was to develop a novel formula for the estimation of urine osmolality using an AutoML tool and to determine the efficiency of AutoML tools in a clinical laboratory setting. Methods: Three hundred routine urinalysis samples were used for reference osmolality and urine clinical chemistry analysis. The H2O AutoML engine completed the machine learning development steps with minimum human intervention. Four feature groups were created, which include different urinalysis measurements according to the Boruta feature selection algorithm. Method comparison statistics including Spearman’s correlation, Passing–Bablok regression analysis were performed, and Bland Altman plots were created to compare model predictions with the reference method. The minimum allowable bias (24.17%) from biological variation data was used as the limit of agreement. Results: The AutoML engine developed a total of 183 ML models. Conductivity and specific gravity had the highest variable importance. Models that include conductivity, specific gravity, and other urinalysis parameters had the highest R 2 (0.70–0.83), and 70–84% of results were within the limit of agreement. Conclusions: Combining urinary conductivity with other urinalysis parameters using validated machine learning models can yield a promising surrogate. Additionally, AutoML tools facilitate the machine learning development cycle and should be considered for developing ML models in clinical laboratories.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recently, due to the complexity inherent in model development, automated ML tools were also introduced to streamline the process, enabling non-experts to create models.”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [11]
In the citing paper
“These tools aim to automate the pipeline of ML model development, including feature engineering, model development, hyperparameter optimization, and performance evaluation, all of which typically necessitate experienced users as shown in Figure 1 [10,11].”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [11]
In the citing paper
“To overcome this problem, automated machine learning (AutoML) tools have been introduced which can build high-quality machine learning models for specific tasks without human expertise.”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [11]
In the citing paper
“Therefore, they reduce the need for data scientists, enabling domain experts to create ML applications with minimal requirements of statistical and ML expertise [11].”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [11]
In the citing paper
“The R value ranged between . and ., and around - % of the results were within the agreed limit.”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as Topcu 2022
Citations
Cites
Feature Selection with the Boruta Package
Kursa, M. B., & Rudnicki, W. R. (2010) · Journal of Statistical Software · doi:10.18637/jss.v036.i11 · Cited by 5,659
AutoML: A survey of the state-of-the-art
He, X., Zhao, K., & Chu, X. (2021) · Knowledge-Based Systems · doi:10.1016/j.knosys.2020.106622 · Cited by 1,691
Automated machine learning: Review of the state-of-the-art and opportunities for healthcare
Waring, J., Lindvall, C., & Umeton, R. (2020) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2020.101822 · Cited by 834
Biological variation and diagnostic accuracy of dehydration assessment markers
Cheuvront, S. N., Ely, B. R., Kenefick, R. W., & Sawka, M. N. (2010) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2010.29490 · Cited by 367
Molecular dynamics study of conductivity of ionic liquids: The Kohlrausch law
Picálek, J., & Kolafa, J. (2007) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2006.12.015 · Cited by 102
Rashidi, H. H., Tran, N. K., Albahra, S., & Dang, L. T. (2021) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13537 · Cited by 97
Previtali, G., Ravasio, R., Seghezzi, M., Buoro, S., & Alessio, M. G. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2017.07.028 · Cited by 84
Feretzakis, G., Sakagianni, A., Loupelis, E., Kalles, D., Skarmoutsou, N., Martsoukou, M., Christopoulos, C., Lada, M., Petropoulou, S., Velentza, A., et al. (2021) · Healthcare Informatics Research · doi:10.4258/hir.2021.27.3.214 · Cited by 77
Lee, M. J., Chang, T. I., Lee, J., Kim, Y. H., Oh, K., Lee, S. W., Kim, S. W., Park, J. T., Yoo, T., Kang, S., et al. (2019) · Kidney & Blood Pressure Research · doi:10.1159/000502291 · Cited by 28
Quantitative urine test strip reading for leukocyte esterase and hemoglobin peroxidase
Oyaert, M., Himpe, J., Speeckaert, M. M., Stove, V. V., & Delanghe, J. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1159 · Cited by 25
Validation of Surrogates of Urine Osmolality in Population Studies
Youhanna, S. C., Bankir, L., Jungers, P., Porteous, D. J., Polašek, O., Bochud, M., Hayward, C., & Devuyst, O. (2017) · American Journal of Nephrology · doi:10.1159/000475769 · Cited by 22
Evaluation of conductivity‐based osmolality measurement in urine using the Sysmex UF5000
Yoo, D., Lee, S. M., Moon, S. Y., Kim, I., & Chang, C. L. (2020) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23586 · Cited by 14
Kavouras, S. A., Suh, H., Vallet, M., Daudon, M., Mauromoustakos, A., Vecchio, M., & Tack, I. (2021) · Urolithiasis · doi:10.1007/s00240-020-01242-2 · Cited by 14
Calculated Versus Measured Urine Osmolarity: Accuracy of Estimated Urine Density
Vidal-Mayo, J. D. J., Olivas‐Martínez, A., Pérez-Díaz, I., Navarro, J. M. L., Sánchez-Landa, E., Carrillo-Maravilla, E., Portillo-González, M., Fagundo‐Sierra, R., & Leal-Villarreal, M. A. D. J. (2018) · Revista de investigaci�n Cl�nica · doi:10.24875/ric.18002598 · Cited by 13
Estimated urinary osmolality based on combined urinalysis parameters: a critical evaluation
Oyaert, M., Speeckaert, M. M., & Delanghe, J. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-1307 · Cited by 13
Democratizing AI: non-expert design of prediction tasks
Bagrow, J. P. (2020) · PeerJ Computer Science · doi:10.7717/peerj-cs.296 · Cited by 11
Ten simple rules for creating a scientific web application
Burnett, J., Dale, R., Hou, C., Palomo-Muñoz, G., Whitney, K. S., Aulenbach, S. M., Bristol, R. S., do Valle, D. R., & Wellman, T. P. (2021) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1009574 · Cited by 9
Prediction of need for intervention in posterior urethral valves: Use of urine osmolality
Wright, A., Wragg, R., Lopes, J., Robb, A., & McCarthy, L. (2017) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2017.11.026 · Cited by 8
Mobile Technology Application for Improved Urine Concentration Measurement Pilot Study
Walawender, L. E., Patterson, J., Strouse, R., Ketz, J., Saxena, V., Alexy, E. R., & Schwaderer, A. L. (2018) · Frontiers in Pediatrics · doi:10.3389/fped.2018.00160 · Cited by 5
Cited by
Machine learning-based clinical decision support using laboratory data
Çubukçu, H. C., Topcu, D. İ., & Yenice, S. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1037 · Cited by 66
Luo, J., Luo, Y., Cheng, X., Liu, X., Wang, F., Fang, F., Cao, J., Liu, W., & Xu, R. (2023) · Bioresource Technology · doi:10.1016/j.biortech.2023.129842 · Cited by 35
How to Monitor Hydration Status and Urine Dilution in Patients with Nephrolithiasis
Travers, S., Prot‐Bertoye, C., Daudon, M., Courbebaisse, M., & Baron, S. (2023) · Nutrients · doi:10.3390/nu15071642 · Cited by 29
“Such methods include conductivity measurement, in addition to biochemical parameters assessment, but their performances are lower than those obtained with traditional osmolality measurements [65,66].”
MethodArtificial intelligence: is it the right time for clinical laboratories?
Padoan, A., & Plebani, M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1015 · Cited by 22
Screening of lung cancer serum biomarkers based on Boruta-shap and RFC-RFECV algorithms
Yue, G. (2024) · Journal of Proteomics · doi:10.1016/j.jprot.2024.105180 · Cited by 12
Metadata
- Authors
- Topcu, D. İ., & Bayraktar, N.
- Affiliations
- Department of Medical Biochemistry , Başkent University Faculty of Medicine , Ankara , Turkey
- Başkent University (TR)
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2022-07-04
- Volume
- 60
- Issue
- 12
- Pages
- 1911-1920
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W4283778555
- Cited by
- 12
- References
- 19
- Citations by year
- 2025: 4 · 2024: 3 · 2023: 3 · 2022: 2
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Sysmex Turkey, Baskent University (KA19/305)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Physical Sciences › Materials Science › Materials Chemistry › Machine Learning in Materials Science
- Keywords
- urine osmolality, automated machine learning, urine analysis, Boruta feature selection, clinical laboratory automation, method comparison
- MeSH terms
- Machine Learning, Algorithms, Humans, Osmolar Concentration, Specific Gravity, Urinalysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.