CoChat

Enzymatische Bestimmung des Gesamtcholesterins mit dem Greiner Selective Analyzer (GSA-II)

Open access
Borner, K., Klose, S. · 1977 · Clinical Chemistry and Laboratory Medicine
Cited by 122

The DOI matches its Crossref record.

Abstract

A fully enzymatic method to determine total cholesterol in serum is described. The method appears especially suitable for adaptation to discrete mechanical analyzers either of the single channel or the multi-channel type. The method uses the enzymes cholesterol esterase (EC 3.1.1.13), cholesterol oxidase (EC 1.1.3.6) and peroxidase (EC 1.11.1.7) with 4-aminophenazone and phenol as substrates in the indicator reaction. The method was adapted to the Greiner Selective Analyzer GSA-II. For this purpose the critical parameters of the reaction were intensively examined. The complete reagent is stable within the GSA II dispenser at 4 degrees C for at least 1 week. By omitting cholesterol oxidase in the blank reagent a sample bland and a partial reagent blank are obtained. Within a range up to 10.4 mmol/1 (4.0 g/l) the maximum colour is developed within 6 minutes. The calibration factor was stable for 4 months. The method allows absolute measurements. At concentrations between 2 and 4 mmol/1 within-batch precision ranged from 0.5 to 1.4%. Precision from day to day for the same control sera amounted to 2.8; 2.0; 2.7 and 2.0% for a period of 3 months. Examination of accuracy yielded satisfying results. Ascorbic acid in the physiological range did not alter results to a significant extent. Catalase or novaminesulfone added in vitro did not interfere. Optical interferences by bilirubin, hemoglobin or turbidity are compensated by a sample blank. A comparison of results with the enzymatic method of Roeschlau et al. (Z. Klin. Chem. Klin. Biochem. 12, 226 (1974)) yielded satisfactory agreement. The limits of detection of the present method can be lowered by a factor of 2.2 by replacing phenol by dihalogen phenols.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.1977.15.1-12.121

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 122

Metadata

Authors
Borner, K., & Klose, S.
Venue
Clinical Chemistry and Laboratory Medicine
Published
1977
Volume
15
Issue
1-12
Pages
121-30
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W1965555467
Cited by
122
References
0
FWCI
2.15
Type
journal article
Language
de
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enzymatische Bestimmung des Gesamtcholesterins mit dem Greiner Selective Analyzer (GSA-II). https://app.cochat.ai/papers/10.1515/cclm.1977.15.1-12.121
The paper
Borner, K., & Klose, S. (1977). Enzymatische Bestimmung des Gesamtcholesterins mit dem Greiner Selective Analyzer (GSA-II). Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm.1977.15.1-12.121

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.