Multicentre Study of a New Enzymatic Method of Cholesterol Determination
Open accessThe DOI matches its Crossref record.
Abstract
A new enzymatic method for the determination of cholesterol in serum and plasma was evaluated in 8 separate laboratories in comparison with routine and reference methods.Investigation of the analytical reliability in the 2-26 mmol/1 measurement ränge showed the following results:1.At the set reading points (10min at 25 °C and 5min at 37 °C) the reaction shows complete Substrate conversion.The colour complex is stable over a period of 60 min.2. The response to cholesterol is linear up to 26 mmol/1.3. Precision within the series was 0.6-2.8% in 20 determinations (coefficient of Variation).Kattermann, Jaworck and Möller: Enzymatic cholesterol determination 4. Day to day precision was 0.5-3.3% in triple determinations of 10 days (coefficient of Variation).5. Accuracy was studied with 2 samples (assigned value: 3.52 and 6.70 mmol/1 respectively).In the case of sample l the mean for the 8 laboratories was 3.44, with a median of 3.44; for sample 2 the values were 6.68 and 6.72.The results demonstrate an excellent transferability.•' 6.In comparison with other enzymatic procedures, the values found with the new test were 5-10% higher; these results agree at all concentration ranges with the reference methods of Abell & Kendall and with those from mass spectrometry. Multiientrische Erprobung einer neuen enzymatischen CholesterinbestimmungZusammenfassung: Eine neue enzymatische Methode zur Bestimmung des Cholesterins in Serum und Plasma wurde in 8 Laboratorien im Vergleich zu Routine-und Referenzmethoden evaluiert.Die Überprüfung der analytischen Zuverlässigkeit ergab im Meßbereich zwischen 2 und 26 mmol/1 folgende Ergebnisse:1. Der Reaktionsverlauf zeigt zu den angegebenen Ablesezeitpunkten (25 °C: 10min und 37 °C: 5 min) vollständigen Substratumsatz und innerhalb von 60 min gute Stabilität des Farbkomplexes.2. Bis zu 26 mmol/1 wird das Cholesterin linear erfaßt. Präzision in derSerie von 0,6-2,8% bei 20 Bestimmungen (Variationskoeffizient).4. Präzision von Tag zu Tag von 0,5-3,3% bei 3fach-Bestimmungen an 10 Tagen (Variationskoeffizient).5. Prüfung auf Richtigkeit mit 2 Proben (Zielwert: 3,52 bzw.6,70 mmol/1).Bei Probe l betrug der Mittelwert der 8 Laboratorien 3,44 und der Median 3,44, bei Probe 2 6,68 und 6,72.Diese Ergebnisse zeigen die sehr gute "Transfefabilität" des Testes in den verschiedenen Laboratorien.6. Im Vergleich mit anderen enzymatischen Verfahren wurden mit dem neuen Test 5-^10% höhere Werte, mit den Referenzmethoden nach Abell & Kendall sowie der Massenspektrometrie übereinstimmende Ergebnisse in allen Konzentrationsbereichen gefunden.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Han, T. S., van Leer, E. M., Seidell, J. C., & Lean, M. E. J. (1995) · BMJ · doi:10.1136/bmj.311.7017.1401 · Cited by 976
Effect of simvastatin on coronary atheroma: the Multicentre Anti-Atheroma Study (MAAS)
MAAS Investigators (1994) · The Lancet · doi:10.1016/s0140-6736(94)92082-6 · Cited by 647
Pietinen, P., Ascherio, A., Korhonen, P., Hartman, A. M., Willett, W. C., Albanes, D., & Virtamo, J. (1997) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009047 · Cited by 557
Dietary intake of fatty acids and fish in relation to cognitive performance at middle age
Kalmijn, S., van Boxtel, M. P. J., Ocké, M., Verschuren, W. M. M., Kromhout, D., & Launer, L. J. (2004) · Neurology · doi:10.1212/01.wnl.0000103860.75218.a5 · Cited by 524
Gall, M.-A., Hougaard, P., Borch-Johnsen, K., & Parving, H.-H. (1997) · BMJ · doi:10.1136/bmj.314.7083.783 · Cited by 445
Metadata
- Authors
- Kattermann, R., Jaworek, D., & Möller, G.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 1984
- Volume
- 22
- Issue
- 3
- Pages
- 245-51
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2011108002
- Cited by
- 151
- References
- 0
- FWCI
- 0.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multicentre Study of a New Enzymatic Method of Cholesterol Determination. https://app.cochat.ai/papers/10.1515/cclm.1984.22.3.245
- The paper
- Kattermann, R., Jaworek, D., & Möller, G. (1984). Multicentre Study of a New Enzymatic Method of Cholesterol Determination. Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm.1984.22.3.245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.