Comparison of Several Regression Procedures for Method Comparison Studies and Determination of Sample Sizes Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part II
Open accessThe DOI matches its Crossref record.
Abstract
In part I of this series (H. Passing & W. Bablok (1983), J. Clin. Chem. Clin. Biochem. 21, 709-720) we described a new biometrical procedure for the evaluation of method comparison studies. In part II we now discuss its properties and compare them with those of other established procedures by means of a simulation study. We demonstrate that the reliability of the results not only depends on the sample size but also on the sampling distribution, the precision of the methods, and the concentration range covered by the samples. Linear regression and principal component procedures are either inadequate or not as reliable as our new procedure. The appropriate sample size is discussed and recommendations are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Serdar, C. C., Cihan, M., Yücel, D., & Serdar, M. A. (2021) · Biochemia medica · doi:10.11613/bm.2021.010502 · Cited by 1,570
Henderson, A. R. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.04.002 · Cited by 319
Collagen type II C-telopeptide fragments as an index of cartilage degradation
Christgau, S., Garnero, P., Fledelius, C., Moniz, C., Ensig, M., Gineyts, E., Rosenquist, C., & Qvist, P. (2001) · Bone · doi:10.1016/s8756-3282(01)00504-x · Cited by 285
A Critical Review of Ultra-Short-Term Heart Rate Variability Norms Research
Shaffer, F., Meehan, Z. M., & Zerr, C. L. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.594880 · Cited by 248
Reporting Standards for a Bland–Altman Agreement Analysis: A Review of Methodological Reviews
Gerke, O. (2020) · Diagnostics · doi:10.3390/diagnostics10050334 · Cited by 246
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
DE JAGER, J., KOOY, A., LEHERT, P., BETS, D., WULFFELÉ, M. G., TEERLINK, T., SCHEFFER, P. G., SCHALKWIJK, C. G., DONKER, A. J. M., & STEHOUWER, C. D. A. (2005) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2004.01420.x · Cited by 220
Validation and verification of measurement methods in clinical chemistry
Theodorsson, E. (2012) · Bioanalysis · doi:10.4155/bio.11.311 · Cited by 68
Improving the Bias of Comparator Methods in Analytical Performance Assessments Through Recalibration
Pleus, S., Eichenlaub, M., Gerber, T., Eriksson Boija, E., Makris, K., Haug, C., & Freckmann, G. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221133107 · Cited by 24
Metadata
- Authors
- Passing, H., & Bablok, W.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 1984
- Volume
- 22
- Issue
- 6
- Pages
- 431-45
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2071774846
- Cited by
- 262
- References
- 0
- FWCI
- 0.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.