CoChat

Circulating Matrix Metalloproteinases and Their Inhibitors in Premature Coronary Atherosclerosis

Noji, Yoshihiro, Kajinami, Kouji, Kawashiri, Masa-aki, Todo, Yasuhiro, Horita, Takahiro, Nohara, Atsushi, Higashikata, Toshinori, Inazu, Akihiro, Koizumi, Junji, Takegoshi, Tadayoshi, Mabuchi, Hiroshi · 2001 · Clinical Chemistry and Laboratory Medicine
Cited by 151

The DOI matches its Crossref record.

Abstract

To investigate the clinical significance of circulating matrix metalloproteinases (MMPs) and their tissue inhibitos (TIMPs) in patients with premature coronary atheroscrelosis, we studied 53 consecutive male patients with angiographically defined premature (<65 years) and stable coronary artery disease. Plasma levels of MMP-2, MMP-3, MMP-9, TIMP-1, and TIMP-2 were determined in peripheral blood by a sandwich enzyme immunoassay, and the results were compared with those from 133 age-matched control males. There were significant differences in all the MMPs and TIMPs (p<0.001) between patients and controls. In the patient group, the levels of MMP-9 (mean +/- SD (ng/ml) 27.2 +/- 15.2/21.8 +/- 15.2) and TIMP-1 (130.4 +/- 55.7/94.5 +/- 26.3) were significantly higher, and the levels of MMP-2 (632.5 +/- 191.6/727.6 +/- 171.4), MMP-3 (53.1 +/- 31.2/79.6 +/- 29.9), and TIMP-2 (24.7 +/- 15.2/35.4 +/- 16.4) were significantly lower than those of controls. We found significant positive correlation between plasma MMP-9 levels and low-density lipoprotein (LDL)-cholesterol levels (Rs = 0.168, p = 0.022), and significant negative correlation between plasma MMP-9 levels and high-density lipoprotein (HDL)-cholesterol levels (Rs = -0.164, p = 0.026) by Spearman rank correlation test. In contrast, plasma MMP-2 (Rs = 0.181, p = 0.014) and MMP-3 (Rs = 0.260, p = 0.0004) levels were positively correlated with HDL-cholesterol levels. TIMP-2 levels were negatively correlated with total cholesterol (Rs = -0.197, p = 0.007) and LDL-cholesterol (Rs = -0.168, p=0.022) levels. These results suggest that the circulating levels of MMPs and TIMPs are altered in patients with premature coronary atherosclerosis and that plasma lipoprotein cholesterol levels correlate with these, possibly as a result of the lipoprotein-vessel wall interactions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2001.060

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 151

Metadata

Authors
Noji, Y., Kajinami, K., Kawashiri, M.-A., Todo, Y., Horita, T., Nohara, A., Higashikata, T., Inazu, A., Koizumi, J., Takegoshi, T., & Mabuchi, H.
Venue
Clinical Chemistry and Laboratory Medicine
Published
2001-01-06
Volume
39
Issue
5
Pages
380-4
ISSN
1434-6621 (ISSN-L)
OpenAlex
W2079610654
Cited by
151
References
0
FWCI
3.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Circulating Matrix Metalloproteinases and Their Inhibitors in Premature Coronary Atherosclerosis. https://app.cochat.ai/papers/10.1515/cclm.2001.060
The paper
Noji, Y., Kajinami, K., Kawashiri, M.-A., Todo, Y., Horita, T., Nohara, A., Higashikata, T., Inazu, A., Koizumi, J., Takegoshi, T., & Mabuchi, H. (2001). Circulating Matrix Metalloproteinases and Their Inhibitors in Premature Coronary Atherosclerosis. Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm.2001.060

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.