First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay – Lp(a) SRM 2B
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Lipoprotein(a) is an important predictor of cardiovascular disease risk. The lack of internationally accepted standardization has impeded the broad application of this lipoprotein in laboratory medicine. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), through its Working Group on Lipoprotein(a) and together with research institutions and several diagnostic companies, have succeeded in developing an international reference material that is intended for the transfer of a lipoprotein(a) concentration to manufacturers' master calibrators. IFCC SRM 2B has recently been accepted by the WHO Expert Committee on Biological Standardization as the ‘First WHO/IFCC International Reference Reagent for Lipoprotein(a) for Immunoassay’. The assigned unitage of 0.1071 nanomoles of lipoprotein(a) per vial is traceable to the consensus reference method for lipoprotein( a) and will enable conformity by diagnostic companies to the European Union's Directive on In vitro Diagnostic Medical Devices for the metrological traceability of calibrator materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marcovina, S. M., Koschinsky, M. L., Albers, J. J., & Skarlatos, S. (2003) · Clinical Chemistry · doi:10.1373/clinchem.2003.023689 · Cited by 288
Self-citation
Cited by
Writing Committee Members, Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3182051b4c · Cited by 1,873
(2009) · JAMA · doi:10.1001/jama.2009.1063 · Cited by 1,753
2010 ACCF/AHA Guideline for Assessment of Cardiovascular Risk in Asymptomatic Adults
Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., Kushner, F. G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.001 · Cited by 1,324
Raal, F., Scott, R., Somaratne, R., Bridges, I., Li, G., Wasserman, S. M., & Stein, E. A. (2012) · Circulation · doi:10.1161/circulationaha.112.144055 · Cited by 508
Lipoprotein(a) and its Significance in Cardiovascular Disease: A Review
Duarte Lau, F., & Giugliano, R. P. (2022) · JAMA Cardiology · doi:10.1001/jamacardio.2022.0987 · Cited by 363
Metadata
- Authors
- Dati, F., Tate, J. R., Marcovina, S. M., & Steinmetz, A.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2004-01-07
- Volume
- 42
- Issue
- 6
- Pages
- 670-6
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2009191878
- Cited by
- 124
- References
- 1
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.