The DOI matches its Crossref record.
Urinary cystatin C as a specific marker of tubular dysfunction
Abstract
BACKGROUND: Cystatin C (CST3), a strong inhibitor of cysteine proteinases, is freely filtered by the kidney glomerulus and is reabsorbed by the tubules, where it is almost totally catabolized, with the remainder then eliminated in urine. In tubular diseases, it seems sensible to postulate that CST3 degradation would be reduced and consequently an increase in its urinary elimination would be observed. METHODS: We report here the development of an automatic quantitative assay to measure CST3 concentrations in urine using a Behring N-Latex Cystatin C kit on a BNII laser nephelometer. We tested its clinical relevance on several kidney disease patients. RESULTS: This assay is sensitive (limit of detection 0.008 mg/L) and precise (within- and between-day CVs < 4%). Reference values for freshly collected urine samples range from 0.03 to 0.18 mg/L. Mean urine CST3 concentrations obtained from 52 patients with kidney tubular disease (4.31 +/- 3.85 mg/L) were significantly higher than those for 60 controls (0.096 +/- 0.044 mg/L; p < 0.0001) and 47 glomerular disease patients (0.106 +/- 0.133 mg/L; p < 0.0001). CONCLUSION: Increased urinary CST3 concentrations allow the accurate detection of tubular dysfunction among pure and mixed nephropathies. Because of its ability to be processed on automated clinical chemistry analyzers, this assay could easily be used as an adjunct to the standard panel used to screen kidney pathologies, even in emergency situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomarkers of Acute Kidney Injury
Vaidya, V. S., Ferguson, M. A., & Bonventre, J. V. (2008) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.48.113006.094615 · Cited by 729
Urinary Biomarkers for Sensitive and Specific Detection of Acute Kidney Injury in Humans
Vaidya, V. S., Waikar, S. S., Ferguson, M. A., Collings, F. B., Sunderland, K., Gioules, C., Bradwin, G., Matsouaka, R., Betensky, R. A., Curhan, G. C., et al. (2008) · Clinical and Translational Science · doi:10.1111/j.1752-8062.2008.00053.x · Cited by 338
Dieterle, F., Perentes, E., Cordier, A., Roth, D. R., Verdes, P., Grenet, O., Pantano, S., Moulin, P., Wahl, D., Mahl, A., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1622 · Cited by 334
Biomarkers of nephrotoxic acute kidney injury
Ferguson, M. A., Vaidya, V. S., & Bonventre, J. V. (2008) · Toxicology · doi:10.1016/j.tox.2007.12.024 · Cited by 322
Drug-Induced Nephrotoxicity and Its Biomarkers
Kim, S.-Y., & Moon, A.-R. (2012) · Biomolecules and Therapeutics · doi:10.4062/biomolther.2012.20.3.268 · Cited by 287
Metadata
- Authors
- Conti, M., Moutereau, S., Zater, M., Lallali, K., Durrbach, A., Manivet, P., Eschwège, P., & Loric, S.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2006-01-01
- Volume
- 44
- Issue
- 3
- Pages
- 288-91
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2098377860
- Cited by
- 208
- References
- 0
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Urinary cystatin C as a specific marker of tubular dysfunction. https://app.cochat.ai/papers/10.1515/cclm.2006.050
- The paper
- Conti, M., Moutereau, S., Zater, M., Lallali, K., Durrbach, A., Manivet, P., Eschwège, P., & Loric, S. (2006). Urinary cystatin C as a specific marker of tubular dysfunction. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm.2006.050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.