Evaluation of the DCA Vantage analyzer for HbA1c assay
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Measurement of HbA 1c is key in monitoring diabetic patients in both laboratories and clinical units, where HbA 1c results are used as part of patient education. METHODS: We have evaluated the DCA Vantage, a new device for immunological assay of HbA 1c. HbA 1c results obtained were evaluated in terms of precision, linearity, specificity and practicability, and were compared with results obtained by a Variant II HPLC method. RESULTS: The method exhibited intra- and inter-assay coefficients of variation lower than 2.6% and 4.0%, respectively, and good correlation with the comparison HPLC method (r2=0.9776). No interference was noted in the presence of labile HbA 1c or carbamylated hemoglobin. The new device exhibited improved practicability characteristics and allowed better sample identification, better management of quality control routines and greater connectivity possibilities compared to the previous DCA 2000 analyzer. CONCLUSIONS: This new analyzer exhibited analytical and practical characteristics very suitable for HbA 1c assay for laboratory or point-of-care use according to good laboratory practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Effects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin
Bry, L., Chen, P. C., & Sacks, D. B. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.2.153 · Cited by 523
Cagliero, E., Levina, E. V., & Nathan, D. M. (1999) · Diabetes Care · doi:10.2337/diacare.22.11.1785 · Cited by 246
Cited by
Lenters-Westra, E., & Slingerland, R. J. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.130641 · Cited by 228
Willard-Grace, R., Chen, E. H., Hessler, D., DeVore, D., Prado, C., Bodenheimer, T., & Thom, D. H. (2015) · The Annals of Family Medicine · doi:10.1370/afm.1768 · Cited by 143
Hirst, J. A., McLellan, J. H., Price, C. P., English, E., Feakins, B. G., Stevens, R. J., & Farmer, A. J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0303 · Cited by 102
Hemoglobin A1c Point-of-Care Assays; A New World with a Lot of Consequences!
Lenters-Westra, E., & Slingerland, R. J. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300303 · Cited by 31
Long-Term Performance of Point-of-Care Hemoglobin A1c Assays
Paknikar, S., Sarmah, R., Sivaganeshan, L., Welke, A., Rizzo, A., Larson, K., & Rendell, M. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816645362 · Cited by 17
Metadata
- Authors
- Szymezak, J., Leroy, N., Lavalard, E., & Gillery, P.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2008-01-01
- Volume
- 46
- Issue
- 8
- Pages
- 1195-8
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2016674668
- Cited by
- 50
- References
- 3
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.