Managing quality vs. measuring uncertainty in the medical laboratory
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
ISO 15189's particular requirements for quality management in medical laboratories provide guidance for (a) relating performance specifications to the intended use of a test or examination procedure, (b) designing internal quality control (IQC) procedures to verify the attainment of the intended quality of test results, as well as (c) determining the uncertainty or results, where relevant and possible. This guidance has particular implications for analytical quality management, specifically for validating method performance relative to quality goals or requirements (intended use), designing statistical quality control procedures on the basis of the quality required for a test and the precision and bias observed for a method, and characterizing the quality achieved in practice by calculating measurement uncertainty. There already exists an error framework that provides practical tools and guidance for managing analytical quality, along with an existing concept of total error that can be used to characterize the quality of laboratory tests, thus there is considerable concern and debate on the merits and usefulness of measurement uncertainty. This paper argues that total error provides a practical top-down estimate of measurement uncertainty in the laboratory, and that the ISO/GUM model should be primarily directed to and applied by manufacturers. Clin Chem Lab Med 2010;48:31–40.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Criteria for judging precision and accuracy in method development and evaluation
Westgard, J. O., Carey, R. N., & Wold, S. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.7.825 · Cited by 236
Self-citation
Cited by
Quality control review: implementing a scientifically based quality control system
Westgard, J. O., & Westgard, S. A. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215597248 · Cited by 109
“Another issue with MU has been the consideration of bias.(55) Clinical laboratory scientists have commonly determined the analytic total error as a measure of quality and performance.”
BackgroundSelf-citationValidation and verification of measurement methods in clinical chemistry
Theodorsson, E. (2012) · Bioanalysis · doi:10.4155/bio.11.311 · Cited by 68
Useful measures and models for analytical quality management in medical laboratories
Westgard, J. O. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0710 · Cited by 64
Self-citationCarobene, A., Franzini, C., & Ceriotti, F. (2011) · cclm · doi:10.1515/cclm.2011.196 · Cited by 21
Metadata
- Authors
- Westgard, J. O.
- Venue
- cclm
- Publisher
- Walter de Gruyter GmbH
- Published
- 2009-11-18
- Volume
- 48
- Issue
- 1
- Pages
- 31-40
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2068432650
- Cited by
- 63
- References
- 2
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.