CoChat

Managing quality vs. measuring uncertainty in the medical laboratory

Westgard, James O. · 2010 · cclm
Cited by 63

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

ISO 15189's particular requirements for quality management in medical laboratories provide guidance for (a) relating performance specifications to the intended use of a test or examination procedure, (b) designing internal quality control (IQC) procedures to verify the attainment of the intended quality of test results, as well as (c) determining the uncertainty or results, where relevant and possible. This guidance has particular implications for analytical quality management, specifically for validating method performance relative to quality goals or requirements (intended use), designing statistical quality control procedures on the basis of the quality required for a test and the precision and bias observed for a method, and characterizing the quality achieved in practice by calculating measurement uncertainty. There already exists an error framework that provides practical tools and guidance for managing analytical quality, along with an existing concept of total error that can be used to characterize the quality of laboratory tests, thus there is considerable concern and debate on the merits and usefulness of measurement uncertainty. This paper argues that total error provides a practical top-down estimate of measurement uncertainty in the laboratory, and that the ISO/GUM model should be primarily directed to and applied by manufacturers. Clin Chem Lab Med 2010;48:31–40.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2010.024

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Westgard, J. O.
Venue
cclm
Published
2009-11-18
Volume
48
Issue
1
Pages
31-40
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2068432650
Cited by
63
References
2
FWCI
3.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.