Common reference intervals for aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyl transferase (GGT) in serum: results from an IFCC multicenter study
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyl transferase (GGT) measurements are important for the assessment of liver damage. The aim of this study was to define the reference intervals (RIs) for these enzymes in adults, paying attention to standardization of the methods used and careful selection of the reference population. Methods: AST, ALT and GGT were measured with commercial analytical systems standardized to the IFCC-recommended reference measurement systems. Three centers (two in Italy and one in China) measured their own freshly collected samples; one of these centers also measured frozen samples from the Nordic Countries RI Project and from a Turkish center. RIs were generated using non-parametric techniques from the results of 765 individuals (411 females and 354 males, 18–85 years old) selected on the basis of the results of other laboratory tests and a specific questionnaire. Results: AST results from the four regions (Milan, Beijing, Bursa and Nordic Countries) were statistically different, but these differences were too small to be clinically relevant. Likewise, differences between the upper reference limits for genders was only 1.7 U/L (0.03 μkat/L), allowing a single RI of 11–34 U/L (0.18–0.57 μkat/L) to be defined. Interregional differences were not statistically significant for ALT, but partitioning was required due to significant gender differences. RIs for ALT were 8–41 U/L (0.13–0.68 μkat/L) for females and 9–59 U/L (0.15–0.99 μkat/L) for males, respectively. The upper reference limits for GGT from the Nordic Country population were higher than those from the other three regions and results from this group were excluded from final calculations. The GGT RIs were 6–40 U/L (0.11–0.66 μkat/L) for females and 12–68 U/L (0.20– 1.13 μkat/L) for males, respectively. Conclusions: For AST and ALT, the implementation of common RIs appears to be possible, because no differences between regions were observed. However, a common RI for GGT that is applicable worldwide appears unlikely due to differences among populations. Clin Chem Lab Med 2010;48:1593–601.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Updated definitions of healthy ranges for serum alanine aminotransferase levels
Prati, D., Taioli, E., Zanella, A., Torre, E. D., Butelli, S., Del Vecchio, E., Vianello, L., Zanuso, F., Mozzi, F., Milani, S., et al. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-1-200207020-00006 · Cited by 1,445
The IFCC recommendation on estimation of reference intervals. The RefVal Program
Solberg, H. E. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.121 · Cited by 258
Reference intervals: the way forward
Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008170 · Cited by 199
Self-citation
Cited by
ACG clinical guideline: evaluation of abnormal liver chemistries
Kwo, P. Y., Cohen, S. M., & Lim, J. K. (2017) · American Journal of Gastroenterology · doi:10.1038/ajg.2016.517 · Cited by 1,222
Haitao, T., Vermunt, J. V., Abeykoon, J., Ghamrawi, R., Gunaratne, M., Jayachandran, M., Narang, K., Parashuram, S., Suvakov, S., & Garovic, V. D. (2020) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2020.07.024 · Cited by 297
Reference intervals: current status, recent developments and future considerations
Ozarda, Y. (2016) · Biochemia Medica · doi:10.11613/bm.2016.001 · Cited by 264
(2015) · Europe PMC (PubMed Central) · Cited by 143
Carobene, A., Strollo, M., Jonker, N., Barla, G., Bartlett, W. A., Sandberg, S., Sylte, M. S., Røraas, T., Sølvik, U. Ø., Fernandez-Calle, P., et al. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0035 · Cited by 110
Self-citation
Metadata
- Authors
- Ceriotti, F., Henny, J., Queraltó, J., Ziyu, S., Özarda, Y., Chen, B., Boyd, J. C., & Panteghini, M.
- Venue
- cclm
- Publisher
- Walter de Gruyter GmbH
- Published
- 2010-10-30
- Volume
- 48
- Issue
- 11
- Pages
- 1593-1601
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2113854355
- Cited by
- 121
- References
- 3
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Common reference intervals for aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyl transferase (GGT) in serum: results from an IFCC multicenter study. https://app.cochat.ai/papers/10.1515/cclm.2010.315
- The paper
- Ceriotti, F., Henny, J., Queraltó, J., Ziyu, S., Özarda, Y., Chen, B., Boyd, J. C., & Panteghini, M. (2010). Common reference intervals for aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyl transferase (GGT) in serum: results from an IFCC multicenter study. cclm. https://doi.org/10.1515/cclm.2010.315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.