A new tool in the field of in-vitro diagnosis of allergy: preliminary results in the comparison of ImmunoCAP© 250 with the ImmunoCAP© ISAC
Open accessThe DOI matches its Crossref record.
Abstract
Background: The ImmunoCAP© ISAC allows for the determination of specific immunoglobulin E (IgE) against 103 recombinant or purified allergen components in a single analytical step. The aim of our study was to perform a comparison of the specific IgE results measured with the microarray method to those obtained using the traditional method of ImmunoCAP©. Methods: We selected 86 clinically relevant patients on the basis of their specific IgE for recombinant allergens (ImmunoCAP© 250, Phadia). Also, we selected two patients with a high total IgE to evaluate the non-specific binding of IgE. All samples were screened with the ImmunoCAP© ISAC. Then, we compared the 555 specific IgE antibodies results provided by ImmunoCAP© ISAC with the specific IgE levels obtained with ImmunoCAP© 250. Results: We observed that 82 of the 384 results found to be positive with ImmunoCAP© were negative with ISAC© (concordance 78.65%). Of 171 negative results obtained with ImmunoCAP©, 11 were positive with ISAC© (concordance 93.57%). No non-specific binding was observed. Conclusions: Our results show that the ImmunoCAP© ISAC has good analytical performance when compared with the ImmunoCAP© 250 method. We did not observe any non-specific binding. However, better sensitivity for some clinically relevant allergen components, such as rPru p 3 is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A WAO - ARIA - GA²LEN consensus document on molecular-based allergy diagnostics
Canonica, G. W., Ansotegui, I. J., Pawankar, R., Schmid-Grendelmeier, P., van Hage, M., Baena-Cagnani, C. E., Melioli, G., Nunes, C., Passalacqua, G., Rosenwasser, L., et al. (2013) · World Allergy Organization Journal · doi:10.1186/1939-4551-6-17 · Cited by 432
Popescu, F.-D., & Vieru, M. (2018) · World Journal of Methodology · doi:10.5662/wjm.v8.i3.17 · Cited by 67
Multiplex component‐based allergen microarray in recent clinical studies
Patelis, A., Borres, M. P., Kober, A., & Berthold, M. (2016) · Clinical & Experimental Allergy · doi:10.1111/cea.12761 · Cited by 49
Westwood, M., Ramaekers, B., Lang, S., Armstrong, N., Noake, C., de Kock, S., Joore, M., Severens, J., & Kleijnen, J. (2016) · Health Technology Assessment · doi:10.3310/hta20670 · Cited by 49
Metadata
- Authors
- Gadisseur, R., Chapelle, J.-P., & Cavalier, E.
- Venue
- cclm
- Publisher
- Walter de Gruyter GmbH
- Published
- 2010-12-14
- Volume
- 49
- Issue
- 2
- Pages
- 277-280
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2050485162
- Cited by
- 81
- References
- 0
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.