The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Review Label-free detection with high-Q microcavities: a review of biosensing mechanisms for integrated devices
Open accessAbstract
Optical microcavities that confine light in high-Q resonance promise all of the capabilities required for a successful next-generation microsystem biodetection technology. Label-free detection down to single molecules as well as operation in aqueous environments can be integrated cost-effectively on microchips, together with other photonic components, as well as electronic ones. We provide a comprehensive review of the sensing mechanisms utilized in this emerging field, their physics, engineering and material science aspects, and their application to nanoparticle analysis and biomolecular detection. We survey the most recent developments such as the use of mode splitting for self-referenced measurements, plasmonic nanoantennas for signal enhancements, the use of optical force for nanoparticle manipulation as well as the design of active devices for ultra-sensitive detection. Furthermore, we provide an outlook on the exciting capabilities of functionalized high-Q microcavities in the life sciences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214
Weighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Cited by
Exceptional points enhance sensing in an optical microcavity
Chen, W., Kaya Özdemir, Ş., Zhao, G., Wiersig, J., & Yang, L. (2017) · Nature · doi:10.1038/nature23281 · Cited by 2,084
Self-citationHow to deal with the loss in plasmonics and metamaterials
Khurgin, J. B. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2014.310 · Cited by 1,125
Wiersig, J. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.203901 · Cited by 1,049
Non-Hermitian Topological Sensors
Budich, J. C., & Bergholtz, E. J. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.180403 · Cited by 394
Piliarik, M., & Sandoghdar, V. (2014) · Nature Communications · doi:10.1038/ncomms5495 · Cited by 332
Metadata
- Authors
- Vollmer, F., & Yang, L.
- Venue
- nanoph
- Publisher
- Walter de Gruyter GmbH
- Published
- 2012-12-01
- Volume
- 1
- Issue
- 3-4
- Pages
- 267-291
- ISSN
- 2192-8606 (ISSN-L)
- 2192-8614
- OpenAlex
- W2130163349
- Cited by
- 546
- References
- 2
- FWCI
- 20.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review Label-free detection with high-Q microcavities: a review of biosensing mechanisms for integrated devices. https://app.cochat.ai/papers/10.1515/nanoph-2012-0021
- The paper
- Vollmer, F., & Yang, L. (2012). Review Label-free detection with high-Q microcavities: a review of biosensing mechanisms for integrated devices. nanoph. https://doi.org/10.1515/nanoph-2012-0021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.