Optimal conditions for indoor air purification using non-thermal Corona discharge electrostatic precipitator

Elaissi, Samira, Alsaif, Norah A.M., Moneer, Eman M., Gouadria, Soumaya · 2025 · Open Physics

Abstract

Cold plasmas improve indoor air quality by reducing fine and ultrafine particles threatening human health. Electrostatic precipitator (ESP) uses non-thermal corona discharge connected to negative DC high voltage needles with grounded parallel plate collectors. In this paper, a simulation of an ESP model is performed using COMSOL Multiphysics software to study optimal conditions for indoor air purification. Numerical results of current voltage distribution display a great correlation with experimental data. The corona current density, potential, electric field strength and density of space charges are investigated. Various geometric and operating parameters are utilized to investigate the ultrafine particles removal efficiency. Moreover, the collection efficiency and migration velocity are discussed according to particle size. ESP performance is affected by number of discharging wires as well as electrode size and configuration. A 94 % efficiency rate of removing particles from 0.01 to 0.25 µm radius is achieved under optimal conditions (40 kV, 1 m/s inlet velocity, five needles). In hence, controlling airborne particles through electrostatic precipitator technology under these optimal conditions has been proven to be reliable to remove ultrafine particles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/phys-2025-0237

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

Research works printed but not linked: 45

  1. Garcia, A, Santa-Helena, E, Falco, AD, Ribeiro, JDP, Gioda, A, Gioda, CR. Toxicological effects of fine particulate matter (PM2.5): health risks and associated systemic injuries–systematic review. Water Air Soil Pollut 2023;234:346. https://doi.org/10.1007/s11270-023-06278-9. · DOI · Paper page
  2. Mannerström, M, Dvorakova, M, Svobodova, L, Rucki, M, Kotal, F, Vavrouš, A, et al.. New approach methods for assessing indoor air toxicity Current Research in Toxicology. Cur Res Toxicol 2022;3:100090. · DOI
  3. Kong, X, Guo, C, Lin, Z, Duan, S, He, J, Ren, Y, et al.. Experimental study on the control effect of different ventilation systems on fine particles in a simulated hospital ward. Sustain Cities Soc 2021;73:103102. https://doi.org/10.1016/j.scs.2021.103102. · doi:10.1016/j.scs.2021.103102
  4. Buggisch, JR, Gohler, D, Pape, AL, Roger, S, Ouaissi, M, Stintz, M, et al.. Experimental model to test electrostatic precipitation technology in the COVID-19 era: a pilot study. J Am Coll Surgeons 2020;231:704–12. · doi:10.1016/j.jamcollsurg.2020.08.759
  5. Jeong, SB, Shin, JH, Kim, SW, Seo, SC, Jung, JH. Performance evaluation of an electrostatic precipitator with a copper plate using an aerosolized SARS-CoV-2 surrogate (bacteriophage phi 6). Environ Technol Innov 2023;30:103124. https://doi.org/10.1016/j.eti.2023.103124. · DOI
  6. Shetty, SS, Deepthi, D, Harshitha, S, Sonkusare, S, Naik, PB, Kumari, S, et al.. Environmental pollutants and their effects on human health. Heliyon 2023;9:19496. https://doi.org/10.1016/j.heliyon.2023.e19496. · DOI · Paper page
  7. Zuraimi, MS, Nilsson, GJ, Magee, RJ. Removing indoor particles using portable air cleaners: implications for residential infection transmission. Build Environ 2011;46:2512–19. https://doi.org/10.1016/j.buildenv.2011.06.008. · DOI
  8. De Oliveira, AE, Guerra, VG. Electrostatic precipitation of nanoparticles and submicron particles: review of technological strategies. Process Saf Environ Prot 2021;153:422–38. https://doi.org/10.1016/j.psep.2021.07.043. · DOI
  9. Li, Z, Liu, Y, Xing, Y, Tran, TMP, Le, TC, Tsai, CJ. Novel wire-on-plate electrostatic precipitator WOP-EP; for controlling fine particle and nanoparticle pollution. Environ Sci Technol 2015;49:8683–90. https://doi.org/10.1021/acs.est.5b01844. · DOI
  10. Kim, M, Lim, GT, Kim, YJ, Han, B, Woo, C, Kim, HJ. A novel electrostatic precipitator-type small air purifier with a carbon fiber ionizer and an activated carbon fiber filter. J Aerosol Sci 2018;117:63–73. https://doi.org/10.1016/j.jaerosci.2017.12.014. · doi:10.1016/j.jaerosci.2017.12.014
  11. Sung, JH, Kim, M, Kim, YJ, Han, B, Hong, KJ, Kim, HJ. Ultrafine particle cleaning performance of an ion spray electrostatic air cleaner emitting zero ozone with diffusion charging by carbon fiber. Build Environ 2019;166:106422. https://doi.org/10.1016/j.buildenv.2019.106422. · DOI
  12. El-Sapa, S, Alotaibi, MA. Slip-driven interaction of dual spheres in couple stress fluids within a permeable medium. Mathematics 2025;13:2065. https://doi.org/10.3390/math13132065. · doi:10.3390/math13132065
  13. Alotaibi, MA, Algatheem, AM, El–Sapa, S. Magneto-slip interaction in the migration of two rigid spheres in infinite couple stress fluid. Chin J Phys 2025;95:173–89. · doi:10.1016/j.cjph.2025.01.044
  14. Anagnostopoulos, J, Bergeles, G. Corona discharge simulation in wire-duct electrostatic precipitator. J Electrostat 2002;54:129–47. https://doi.org/10.1016/s0304-3886(01)00172-3. · doi:10.1016/s0304-3886(01)00172-3
  15. Liu, Y, Hu, B, Zhou, L, Jiang, Y, Yang, L. Improving the removal of fine particles with an electrostatic precipitator by chemical agglomeration. Energ Fuel 2016;30:8441–7. https://doi.org/10.1021/acs.energyfuels.6b00626. · doi:10.1021/acs.energyfuels.6b00626
  16. Al-Hanaya, A, El-Sapa, S. Impact of permeability and fluid parameters in couple stress media on rotating eccentric spheres. Open Phys 2024;22:20240112. https://doi.org/10.1515/phys-2024-0112. · doi:10.1515/phys-2024-0112
  17. El-Sapa, S, Alotaibi, MA. Migration of two rigid spheres translating within an infinite couple stress fluid under the impact of magnetic field. Open Phys 2024;22:20240085. https://doi.org/10.1515/phys-2024-0085. · doi:10.1515/phys-2024-0085
  18. Yang, Z, Zheng, C, Liu, S, Guo, Y, Liang, C, Zhang, X, et al.. Insights into the role of particle space charge effects in particle precipitation processes in electrostatic precipitator. Powder Technol 2018;339:606–14. https://doi.org/10.1016/j.powtec.2018.08.056. · DOI
  19. Chen, B, Li, H, He, Y, Liu, B, Zhang, L. Study on performance of electrostatic precipitator under multi-physics coupling. Environ Sci Pollut R 2019;26:35023–33. https://doi.org/10.1007/s11356-019-06623-8. · doi:10.1007/s11356-019-06623-8
  20. Guo, B, Yu, A, Guo, J. Numerical modelling of ESP for design optimization. Procedia Engineer 2015;102:1366–72. https://doi.org/10.1016/j.proeng.2015.01.268. · doi:10.1016/j.proeng.2015.01.268
  21. Afshari, A, Ekberg, L, Forejt, L, Mo, J, Rahimi, S, Siegel, J, et al.. Electrostatic precipitators as an indoor air cleaner–A literature review. Sustainability 2020;12:8774. https://doi.org/10.3390/su12218774. · DOI
  22. Cornette, JFP, Dyakov, IV, Plissart, P, Bram, S, Blondeau, J. In-situ evaluation of a commercial electrostatic precipitator integrated in a small-scale wood chip boiler. J Electrostat 2024;128:103897. https://doi.org/10.1016/j.elstat.2024.103897. · DOI
  23. Wang, X, Su, H, Wang, B, Tao, J. Numerical simulation of spiked electrode electrostatic precipitator. J Electrostat 2024;132:103987. https://doi.org/10.1016/j.elstat.2024.103987. · doi:10.1016/j.elstat.2024.103987
  24. Kim, SH, Lee, KW. Experimental study of electrostatic precipitator performance and comparison with existing theoretical prediction models. J Electrostat 1999;48:3–25. https://doi.org/10.1016/s0304-3886(99)00044-3. · doi:10.1016/s0304-3886(99)00044-3
  25. Chen, L, Gonze, E, Ondarts, M, Outin, J, Gonthier, Y. Electrostatic precipitator for fine and ultrafine particle removal from indoor air environments. Sep Purif Technol 2020;247:116964. https://doi.org/10.1016/j.seppur.2020.116964. · DOI
  26. Chen, YT, Lu, CL, Lu, SJ, Lee, DS. Electrostatic precipitator design optimization for the removal of aerosol and airborne viruses. Sustainability-Basel 2023;15:8432. https://doi.org/10.3390/su15108432. · doi:10.3390/su15108432
  27. Zheng, C, Zhang, X, Yang, Z, Liang, C, Guo, Y, Wang, Y, et al.. Numerical simulation of Corona discharge and particle transport behavior with the particle space charge effect. J Aerosol Sci 2018;118:22–33. https://doi.org/10.1016/j.jaerosci.2018.01.008. · doi:10.1016/j.jaerosci.2018.01.008
  28. Adamiak, K. Numerical models in simulating wire-plate electrostatic precipitators: a review. J Electrostat 2013;71:673–80. https://doi.org/10.1016/j.elstat.2013.03.001. · DOI
  29. Lawless, PA, Sparks, LE. Modelling particulate charging in ESPs. IEEE T Ind Appl 1988;24:922–7. https://doi.org/10.1109/28.8999. · DOI
  30. Farnoosh, N, Adamiak, K, Peter, GS. Castle numerical calculations of submicron particle removal in a spike-plate electrostatic precipitator. IEEE T Dielect El 2011;18:1439–52. · DOI
  31. Feng, Z, Long, Z, Yu, T. Filtration characteristics of fibrous filter following an electrostatic precipitator. J Electrostat 2016;83:52–62. https://doi.org/10.1016/j.elstat.2016.07.009. · DOI
  32. Khare, M, Sinha, M. Computer-aided simulation of efficiency of an electrostatic precipitator. Environ Int 1996;22:451–62. https://doi.org/10.1016/0160-4120(96)00033-5. · doi:10.1016/0160-4120(96)00033-5
  33. Roginskaya, L, Yalalova, Z, Gorbunov, A, Karimov, R, Tereshkin, V, Senyushkin, N. Investigation of the high-voltage converter for powering electrostatic precipitators. E3S Web Conf 2023;446:02008. https://doi.org/10.1051/e3sconf/202344602008. · doi:10.1051/e3sconf/202344602008
  34. Lee, EM. Modelling of a novel large-scale electrohydrodynamic vortex flow induced by variation in current density for drag reduction with implication of electrostatic particle clustering. J Electrost 2024;128:103899. https://doi.org/10.1016/j.elstat.2024.103899. · doi:10.1016/j.elstat.2024.103899
  35. Kim, S, Hwang, J. Numerical methodology to evaluate unipolar saturation current limit of DC Corona discharge in complex geometries. Sci Rep-UK 2022;12:14252. https://doi.org/10.1038/s41598-022-18144-5. · doi:10.1038/s41598-022-18144-5
  36. Kasdi, A. Computation and measurement of Corona current density and V-I characteristics in wires-to-plates electrostatic precipitator. J Electrostat 2016;81:1–8. https://doi.org/10.1016/j.elstat.2016.02.005. · doi:10.1016/j.elstat.2016.02.005
  37. Asipuela, A, Iváncsy, T. Study and numerical simulation of the electrical properties of a duct-type electrostatic precipitator using seven circular Corona wires: a review periodica polytechnica. Electr Eng Comput Sci 2022;66:286–93. · doi:10.3311/ppee.19482
  38. Shen, H, Yu, W, Jia, H, Kang, Y. Electrohydrodynamic flows in electrostatic precipitator of five shaped collecting electrodes. J Electrostat 2018;95:61–70. https://doi.org/10.1016/j.elstat.2018.08.002. · DOI
  39. Lagarias, JS. Discharge electrodes and electrostatic precipitators. Japca J AIR Waste Ma 1960;10:271–4. https://doi.org/10.1080/00022470.1960.10467929. · doi:10.1080/00022470.1960.10467929
  40. Gao, W, Wang, Y, Zhang, H, Guo, B, Zheng, C, Guo, J, et al.. Numerical simulation of particle migration in electrostatic precipitator with different electrode configurations. Powder Technol 2020;361:238–47. https://doi.org/10.1016/j.powtec.2019.08.046. · DOI
  41. Andrade, RGSA, Guerra, VG. Discharge electrode influence on electrostatic precipitation of nanoparticles. Powder Technol 2020;379:417–27. https://doi.org/10.1016/j.powtec.2020.10.087. · doi:10.1016/j.powtec.2020.10.087
  42. Ji, X, Huang, J, Teng, L, Li, S, Li, X, Cai, W, et al.. Advances in particulate matter filtration: materials, performance, and application. Green Energy Environ 2023;8:673–97. https://doi.org/10.1016/j.gee.2022.03.012. · DOI · Paper page
  43. Bologa, AA, Seifert, H, Paur, HR, Hering, W. Influence of gas composition on corona discharge characteristics in the high temperature/ high pressure electrostatic precipitator in Proceedings of 12th International Conference on Electrostatic Precipitation-ICESP’XII Nuremberg, Germany; 2011.
  44. Guo, BY, Yu, AB, Guo, J. Numerical modelling of electrostatic precipitation: effect of gas temperature. J Aerosol Sci 2014;77:102–15. https://doi.org/10.1016/j.jaerosci.2014.07.009. · doi:10.1016/j.jaerosci.2014.07.009
  45. Shen, H, Jia, H, Kang, Y. Electrical characteristics and electrohydrodynamic flows in electrostatic precipitator of six shaped discharge electrodes. J Appl Fluid Mech 2020;13:1707–18. · doi:10.36884/jafm.13.06.31085

Metadata

Authors
Elaissi, S., Alsaif, N. A. M., Moneer, E. M., & Gouadria, S.
Venue
Open Physics
Published
2025-01-01
Volume
23
Issue
1
ISSN
2391-5471
Cited by
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimal conditions for indoor air purification using non-thermal Corona discharge electrostatic precipitator. https://app.cochat.ai/papers/10.1515/phys-2025-0237
The paper
Elaissi, S., Alsaif, N. A. M., Moneer, E. M., & Gouadria, S. (2025). Optimal conditions for indoor air purification using non-thermal Corona discharge electrostatic precipitator. Open Physics. https://doi.org/10.1515/phys-2025-0237

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.