CoChat

Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review

Open access
Jalili, Vahid, Barkhordari, Abdullah, Ghiasvand, Alireza · 2020 · Reviews in Analytical Chemistry

The DOI matches its Crossref record; 196 of the 196 references it cites were found in a registry or an index; 22 of the 177 sources its claims cite were checked for support.

Abstract

Abstract Polycyclic aromatic hydrocarbons (PAHs) are a large group of organic compounds comprised of two or more fused benzene rings, which arise from the incomplete combustion of organic materials. These compounds have been of concern as carcinogens and mutagens for the past 50-60 years. Lately, they are also receiving attention as endocrine-disrupting chemicals. Therefore, proper analytical methods are required for sampling and analyzing these compounds. In response to problems associated with the conventional methods like solid-phase extraction (SPE) and liquid-liquid extraction (LLE), many studies have focused on the miniaturization of different sample preparation techniques. In this regard, the use of different types of liquid phase microextraction (LPME) techniques has increased significantly during the recent few decades. LPME techniques are advantageous because they use single-step sample preparation and have shown a greater sensitivity, selectivity, and efficiency than the conventional methods. In addition, these techniques have good potential for automation, to reduce the time and cost of analysis. This review focuses on the most important configurations of LPME including single‐drop microextraction (SDME), hollow-fiber liquid-phase microextraction (HF-LPME), and dispersive liquid-liquid microextraction (DLLME) techniques used for the sampling and determination of PAHs in different samples, along with their cons and pros, as well as their prospects.

Overview

CoChat Summary

TL;DR

This review summarizes liquid-phase microextraction (LPME) configurations—single-drop microextraction (SDME), hollow-fiber LPME (HF-LPME), and dispersive liquid-liquid microextraction (DLLME)—for sampling and determination of polycyclic aromatic hydrocarbons (PAHs). It reports applications across environmental, food, and other matrices, and discusses extraction media, influential parameters, advantages, drawbacks, and prospects.

Key findings

  • LPME techniques are described as miniaturized, single-step sample preparation methods with greater sensitivity, selectivity, and efficiency than conventional SPE and LLE, plus lower organic-solvent consumption and good automation potential.
  • The review tabulates PAH applications with reported performance: e.g., SDME-HPLC-FLD LODs of 0.004–0.247 ng mL⁻¹; HF-LPME-HPLC-UV for cigarette filter tar with LODs of 0.040–0.136 ng mL⁻¹, model recoveries 63–97%, real-sample recoveries 8–71%, and enrichment factors 208–320 (model) and 27–234 (real); DLLME-GC-MS with LODs of 0.3–7.8 ng L⁻¹, enrichment factors 372–1308, and recoveries 87–105%.
  • Extraction media discussed include ionic liquids (ILs), magnetic ionic liquids (MILs), deep eutectic solvents (DESs), and supramolecular solvents (SUPRASs); ILs are called “green solvents” but concerns remain about cost, toxicity, and causticity, while DESs are highlighted as biodegradable, low-toxicity, low-cost, and easy to prepare.
  • Influential parameters include organic solvent choice, sample and extractant volumes, extraction time, pH, agitation, and salting-out; DLLME extraction time is generally shorter than SDME and HF-LPME due to the large extractant–sample surface area in the dispersed system.

Methods

  • Narrative review of LPME techniques for PAH sampling and analysis, stated as the first review on this subject.
  • Draws on published literature and summarizes applications in tables, including Table 3 on LPME techniques in various PAH matrices and Table 2 on physicochemical properties of 16 US EPA priority PAHs.
  • Main analysis is qualitative synthesis of configurations, extraction media, influential parameters, and advantages/drawbacks; no systematic search strategy or meta-analysis is described.

Limitations

  • The paper states no explicit limitations.
  • Evident from the text: it is a narrative review focused on “the most important configurations” and selected literature examples, without systematic search criteria or quantitative synthesis.
  • Evident from the text: reported applications use varied matrices, instruments, and conditions, which limits direct comparability across studies.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1515/revac-2020-0101

Cites

196 of 196 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

22 Valid · 7 Not valid · 135 Not checked · 49 Own results and interpretations

87 more claims · 5 with their cited sources checked

Create a free account to see all 213 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 69
  • It may state two separate claims as one. 71
  • The quote only partly states this claim. 2

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

4 of 4

Citations

Cites

Show all 196 references

Cited by

See all 50

Metadata

Authors
Jalili, V., Barkhordari, A., & Ghiasvand, A.
Affiliations
  • Shahid Beheshti University (IR)
  • Shahroud University of Medical Sciences (IR)
  • University of Tasmania (AU)
Corresponding author
Barkhordari, Abdullah
Venue
Reviews in Analytical Chemistry
Published
2020-01-01
Volume
39
Issue
1
Pages
1-19
ISSN
  • 0793-0135 (ISSN-L)
  • 2191-0189
OpenAlex
W3033096798
Cited by
50
References
191
Citations by year
2026: 7 · 2025: 2 · 2024: 10 · 2023: 11 · 2022: 8 · 2021: 11 · 2020: 1
FWCI
1.03
Type
journal article
Language
en
Open access
Locations
  • Reviews in Analytical Chemistry (publishedVersion, cc-by)
  • UTAS Research Repository (acceptedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
polycyclic aromatic hydrocarbons, liquid-phase microextraction, single-drop microextraction, hollow fiber liquid phase microextraction, dispersive liquid-liquid microextraction, sample preparation miniaturization, PAH determination, endocrine disruptors, carcinogens

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-09-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-09-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review. https://app.cochat.ai/papers/10.1515/revac-2020-0101
The paper
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020). Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review. Reviews in Analytical Chemistry. https://doi.org/10.1515/revac-2020-0101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.