Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review
Open accessThe DOI matches its Crossref record; 196 of the 196 references it cites were found in a registry or an index; 22 of the 177 sources its claims cite were checked for support.
Abstract
Abstract Polycyclic aromatic hydrocarbons (PAHs) are a large group of organic compounds comprised of two or more fused benzene rings, which arise from the incomplete combustion of organic materials. These compounds have been of concern as carcinogens and mutagens for the past 50-60 years. Lately, they are also receiving attention as endocrine-disrupting chemicals. Therefore, proper analytical methods are required for sampling and analyzing these compounds. In response to problems associated with the conventional methods like solid-phase extraction (SPE) and liquid-liquid extraction (LLE), many studies have focused on the miniaturization of different sample preparation techniques. In this regard, the use of different types of liquid phase microextraction (LPME) techniques has increased significantly during the recent few decades. LPME techniques are advantageous because they use single-step sample preparation and have shown a greater sensitivity, selectivity, and efficiency than the conventional methods. In addition, these techniques have good potential for automation, to reduce the time and cost of analysis. This review focuses on the most important configurations of LPME including single‐drop microextraction (SDME), hollow-fiber liquid-phase microextraction (HF-LPME), and dispersive liquid-liquid microextraction (DLLME) techniques used for the sampling and determination of PAHs in different samples, along with their cons and pros, as well as their prospects.
Overview
CoChat Summary
TL;DR
This review summarizes liquid-phase microextraction (LPME) configurations—single-drop microextraction (SDME), hollow-fiber LPME (HF-LPME), and dispersive liquid-liquid microextraction (DLLME)—for sampling and determination of polycyclic aromatic hydrocarbons (PAHs). It reports applications across environmental, food, and other matrices, and discusses extraction media, influential parameters, advantages, drawbacks, and prospects.
Key findings
- LPME techniques are described as miniaturized, single-step sample preparation methods with greater sensitivity, selectivity, and efficiency than conventional SPE and LLE, plus lower organic-solvent consumption and good automation potential.
- The review tabulates PAH applications with reported performance: e.g., SDME-HPLC-FLD LODs of 0.004–0.247 ng mL⁻¹; HF-LPME-HPLC-UV for cigarette filter tar with LODs of 0.040–0.136 ng mL⁻¹, model recoveries 63–97%, real-sample recoveries 8–71%, and enrichment factors 208–320 (model) and 27–234 (real); DLLME-GC-MS with LODs of 0.3–7.8 ng L⁻¹, enrichment factors 372–1308, and recoveries 87–105%.
- Extraction media discussed include ionic liquids (ILs), magnetic ionic liquids (MILs), deep eutectic solvents (DESs), and supramolecular solvents (SUPRASs); ILs are called “green solvents” but concerns remain about cost, toxicity, and causticity, while DESs are highlighted as biodegradable, low-toxicity, low-cost, and easy to prepare.
- Influential parameters include organic solvent choice, sample and extractant volumes, extraction time, pH, agitation, and salting-out; DLLME extraction time is generally shorter than SDME and HF-LPME due to the large extractant–sample surface area in the dispersed system.
Methods
- Narrative review of LPME techniques for PAH sampling and analysis, stated as the first review on this subject.
- Draws on published literature and summarizes applications in tables, including Table 3 on LPME techniques in various PAH matrices and Table 2 on physicochemical properties of 16 US EPA priority PAHs.
- Main analysis is qualitative synthesis of configurations, extraction media, influential parameters, and advantages/drawbacks; no systematic search strategy or meta-analysis is described.
Limitations
- The paper states no explicit limitations.
- Evident from the text: it is a narrative review focused on “the most important configurations” and selected literature examples, without systematic search criteria or quantitative synthesis.
- Evident from the text: reported applications use varied matrices, instruments, and conditions, which limits direct comparability across studies.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
22 Valid · 7 Not valid · 135 Not checked · 49 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“They can form different ionic, hydrogen bonding, π-cation, and hydrophobic interactions with target analytes to enhance the extraction efficiency [153,154].”
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 4.4 Supramolecular solvents
What the sources say
- Partly supportedcites [153] Ballesteros-Gómez A, Rubio S, Pérez-Bendito D. Potential of supramolecular solvents for the extraction of contaminants in liquid foods. J Chromatogr A. 2009;1216:530–9. sourceExperimental — accuracy not yet measured
The Introduction says the selected supramolecular solvent binds analytes through hydrophobic and hydrogen-bond interactions, and Section 3.1 links those interactions to efficient extraction. Our copy does not establish ionic or π-cation interactions with target analytes. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [154] Rezaei F, Yamini Y, Moradi M, Daraei B. Supramolecular solvent-based hollow fiber liquid phase microextraction of benzodiazepines. Anal Chim Acta. 2013;804:135–42. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“These solvents have the ability to extract both dissociated and undissociated forms of acidic compounds [143].”
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 4.3 Deep eutectic solvents
What the sources say
- Partly supportedcites [143] van Osch DJ, Zubeir LF, van den Bruinhorst A, Rocha MA, Kroon MC. Hydrophobic deep eutectic solvents as water-immiscible extractants. Green Chem. 2015;17:4518–21. sourceExperimental — accuracy not yet measured
In the section labeled “14,15” (page not supplied), the paper says the new hydrophobic DESs “could have” the capability to extract both forms of the acids. The citing sentence presents that tentative possibility as an established ability of DESs generally. The same passage reports the established ability for Aliquat 336, a different extractant. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The results showed that extraction solvents with low viscosity and low polarity have higher extraction efficiency.”
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 3.3 Dispersive liquid-liquid microextraction technique
What the sources say
- Supportedcites [118] Tan YH, Chai MK, Wong LS. The effects of parameters on the efficiency of DLLME in extracting of PAHs from vegetable samples. Int J Eng Technol. 2018;7:15–21. source
The Conclusions (p. 5) attribute the high extraction efficiency of 1-bromo-3-methylbutane for PAHs in vegetable samples to its low viscosity and non-polarity. This supports the citing sentence as a summary of the study’s results. (LLM, conf=0.91)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The results demonstrated that the MAE-DLLME-GC-FID method can be successfully used for the sampling and analysis of PAHs in vegetable samples [118].”
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 3.3 Dispersive liquid-liquid microextraction technique
What the sources say
- Supportedcites [118] Tan YH, Chai MK, Wong LS. The effects of parameters on the efficiency of DLLME in extracting of PAHs from vegetable samples. Int J Eng Technol. 2018;7:15–21. source
The Abstract (p. 1) describes MAE-DLLME followed by GC-FID as an effective method for determining PAHs in vegetable samples. The Conclusions (p. 5) report extraction of 13 PAHs and propose the combined method for their determination; the tested sample was spiked cabbage (Sample Preparation, p. 2). (LLM, conf=0.88)
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“These solvents have been widely used in extraction methods due to their high ability to extract various compounds including organic and inorganic specie [152].”
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 4.4 Supramolecular solvents
What the sources say
- Supportedcites [152] Seebunrueng K, Dejchaiwatana C, Santaladchaiyakit Y, Srijaranai S. Development of supramolecular solvent based microextraction prior to high performance liquid chromatography for simultaneous determination of phenols in environmental water, RSC. Adv. 2017;7:50143–9. source
The Introduction states that SUPRASs have been widely used in extraction and preconcentration because they can extract various substances, including organic and inorganic species. This directly supports the cited background claim. (LLM, conf=0.94)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
87 more claims · 5 with their cited sources checked
Create a free account to see all 213 claims and every source verdict.
- Probably not a substantial claim. 69
- It may state two separate claims as one. 71
- The quote only partly states this claim. 2
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 2 Polycyclic aromatic hydrocarbons
“DLLME Aqueous sample HPLC 0.1-500 0.9980-0.99960.045-1.1 -[114]”
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 3.3 Dispersive liquid-liquid microextraction technique
“In addition, the results showed correlation coefficients between 0.99600 and 0.9986.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 3.3 Dispersive liquid-liquid microextraction technique
“The DLLME technique exhibited good linearity in the range of 0.2-600 μg L -1 with correlation coefficients higher than 0.999.”
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 2 Polycyclic aromatic hydrocarbons
“DLLME Aqueous sample HPLC 0.2-600 0.9856 -0.9999 0.02-0.60.02-0.61[117]”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 2 Polycyclic aromatic hydrocarbons
“0.36-1.6 ( ng g -1 )”
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 2 Polycyclic aromatic hydrocarbons
“0.11-0.48( ng g -1 )”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 2 Polycyclic aromatic hydrocarbons
“DLLME Tea beverages HPLC-FLD 1-500 0.9952-0.99990.00202-0.002860.00673-0.0952[61]”
§ Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review > 3.3 Dispersive liquid-liquid microextraction technique
“The LOD and LOQ values ranged from 2.0 to 30.8 ng L -1 and 6.73 to 95.2 ng L -1 , respectively.”
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · cited 1×
“DLLME is a powerful preparation technique based on the use of a ternary solvent system [101].”
MethodA review of airborne polycyclic aromatic hydrocarbons (PAHs) and their human health effects
Kim, K.-H., Jahan, S. A., Kabir, E., & Brown, R. J. C. (2013) · Environment International · doi:10.1016/j.envint.2013.07.019 · Cited by 2,420 · cited 2×
“However, different PAHs have different effects on health, and some PAHs are more heavily studied due to their highly adverse effects on humans [44, 45].”
BackgroundStructure and Nanostructure in Ionic Liquids
Hayes, R., Warr, G. G., & Atkin, R. (2015) · Chemical Reviews · doi:10.1021/cr500411q · Cited by 2,293 · cited 1×
“ILs are composed of large asymmetric organic cations and inorganic or organic anions and their characters are determined by the structure and interaction of the ions in the melt [121, 122].”
BackgroundLei, Z., Chen, B., Koo, Y.-M., & MacFarlane, D. R. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00246 · Cited by 1,460 · cited 1×
“The high solubility of organic species in ILs makes them appropriate solvents for the extraction of various analytes from a variety of sample matrices [123-125].”
BackgroundSolvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245 · cited 1×
“In 1999, HF-LPME was introduced by Pedersen and Rasmussen as a way of avoiding the drop instability in SDME [66, 78].”
MethodCancer risk from occupational and environmental exposure to polycyclic aromatic hydrocarbons
Boffetta, P., Jourenkova, N., & Gustavsson, P. (1997) · Cancer Causes & Control · doi:10.1023/a:1018465507029 · Cited by 1,037
Hydrophobic deep eutectic solvents as water-immiscible extractants
van Osch, D. J. G. P., Zubeir, L. F., van den Bruinhorst, A., Rocha, M. A. A., & Kroon, M. C. (2015) · Green Chemistry · doi:10.1039/c5gc01451d · Cited by 987 · cited 1×
“These solvents have the ability to extract both dissociated and undissociated forms of acidic compounds [143].”
BackgroundEvolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971 · cited 1×
“Nevertheless, DLLME can also be used in combination with other analytical tools such as LC [104, 105].”
MethodBerijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Cited by
Deep eutectic solvents in liquid-phase microextraction: Contribution to green chemistry
Santos, L. B., de Assis, R. D. S., Barreto, J. A., Bezerra, M. A., Novaes, C. G., & Lemos, V. A. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116478 · Cited by 162
Research progress in the use of liquid-liquid extraction for food flavour analysis
Jiang, H., Yang, S., Tian, H., & Sun, B. (2023) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2023.01.005 · Cited by 115
Green microextraction methodologies for sample preparations
Kokosa, J. M., & Przyjazny, A. (2022) · Green Analytical Chemistry · doi:10.1016/j.greeac.2022.100023 · Cited by 84
Song, X., Li, F., Yan, T., Tian, F., Ren, L., Jiang, C., Wang, Q., & Zhang, S. (2022) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2022.07.047 · Cited by 72
Azari, A., Abtahi, M., Dobaradaran, S., Saeedi, R., Yari, A. R., Vaziri, M. H., Razavinasab, S. A., Mohammad, M., Yaghmaeain, K., & Jaafarzadeh, N. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.108791 · Cited by 66
Metadata
- Authors
- Jalili, V., Barkhordari, A., & Ghiasvand, A.
- Affiliations
- Shahid Beheshti University (IR)
- Shahroud University of Medical Sciences (IR)
- University of Tasmania (AU)
- Corresponding author
- Barkhordari, Abdullah
- Venue
- Reviews in Analytical Chemistry
- Publisher
- Walter de Gruyter GmbH
- Published
- 2020-01-01
- Volume
- 39
- Issue
- 1
- Pages
- 1-19
- ISSN
- 0793-0135 (ISSN-L)
- 2191-0189
- OpenAlex
- W3033096798
- Semantic Scholar
- 811ac4a99fe51421a4e6783498565e63708fdc49
- Cited by
- 50
- References
- 191
- Citations by year
- 2026: 7 · 2025: 2 · 2024: 10 · 2023: 11 · 2022: 8 · 2021: 11 · 2020: 1
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Reviews in Analytical Chemistry (publishedVersion, cc-by)
- UTAS Research Repository (acceptedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- polycyclic aromatic hydrocarbons, liquid-phase microextraction, single-drop microextraction, hollow fiber liquid phase microextraction, dispersive liquid-liquid microextraction, sample preparation miniaturization, PAH determination, endocrine disruptors, carcinogens
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review. https://app.cochat.ai/papers/10.1515/revac-2020-0101
- The paper
- Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020). Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review. Reviews in Analytical Chemistry. https://doi.org/10.1515/revac-2020-0101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.