Compliance With Intended Use of Bar Code Medication Administration in Acute and Long-Term Care: An Observational Study
The DOI matches its Crossref record; 14 of the 15 references it cites were found in a registry or an index.
Abstract
Objective: To identify the types and extent of workaround strategies with the use of Bar Code Medication Administration (BCMA) in acute care and long-term care settings. Background: Medication errors are the most commonly documented cause of adverse events in hospital settings. Scanning of bar codes to verify patient and medication information may reduce medication errors. Method: A prospective ethnographic study was conducted using targeted observation. Fifteen acute care and 13 long-term care nurses were directly observed during medication administration at small, medium, and large Veterans Administration hospitals to detect workaround strategies. Results: Noncompliance with recommended practices was observed in all settings and facilities. A larger proportion of acute care nurses than long-term care nurses scanned bar-coded wristbands to identify patients (53% vs. 8%, p = .016). A larger proportion of acute care nurses than long-term care nurses administered barcoded medications immediately after scanning (93% vs. 23%, p < .001). Conclusion: Workaround strategies were employed with BCMA that increased efficiency but created new potential paths to adverse events. There was a significant difference in the rate of use of workaround strategies between acute and long-term care. Application: The extent of workaround strategies varied by care setting and facility. BCMA should be tailored to the long-term care setting, including increasing the efficiency of use. Hospitals implementing bar coding should facilitate the intended use through equipment procurement, implementation, and quality improvement strategies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“What has been demonstrated is that some users deviate from written BCMA-use protocols.”
From Workarounds to Barcode Medication Administration Systems: Their Occurrences, Causes, and Threats to Patient Safety (2008) · cites this paper as [14]
In the citing paper
“These data show that as with all health care technologies, 24-29 suboptimal design and implementation of BCMAs can facilitate new medication administration hazards, 13-15,30-32 lead clinicians to deviate from required safe-use protocols, reduce the technology's safety benefits, 12-15 and enhance the probability of medication errors.”
From Workarounds to Barcode Medication Administration Systems: Their Occurrences, Causes, and Threats to Patient Safety (2008) · cites this paper as [14]
In the citing paper
“They are the focus of educational campaigns and appear in the literature. 12-14”
From Workarounds to Barcode Medication Administration Systems: Their Occurrences, Causes, and Threats to Patient Safety (2008) · cites this paper as [14]
Citations
Cites
Hutchins, E. (1995) · doi:10.7551/mitpress/1881.001.0001 · Cited by 10,801 · cited 1×
“Three observers trained in ethnographic observations in complex settings (Hutchins, 1995) conducted all observations.”
BackgroundBrennan, T. A., Leape, L. L., Laird, N. M., Hebert, L., Localio, A. R., Lawthers, A. G., Newhouse, J. P., Weiler, P. C., & Hiatt, H. H. (1991) · New England Journal of Medicine · doi:10.1056/nejm199102073240604 · Cited by 4,627
Protocol Analysis: Verbal Reports as Data
Venkatesan, M., Ericsson, K. A., & Simon, H. A. (1986) · Journal of Marketing Research · doi:10.2307/3151491 · Cited by 4,347
Leape, L. L., Brennan, T. A., Laird, N., Lawthers, A. G., Localio, A. R., Barnes, B. A., Hebert, L., Newhouse, J. P., Weiler, P. C., & Hiatt, H. (1991) · New England Journal of Medicine · doi:10.1056/nejm199102073240605 · Cited by 3,711 · cited 2×
“Medication errors are the most commonly documented cause of adverse events in hospital settings (Leape et al., 1991), with rates ranging from 3.”
BackgroundInfluentialProtocol Analysis: Verbal Reports as Data
Ericsson, K. A., & Simon, H. A. (1993) · doi:10.7551/mitpress/5657.001.0001 · Cited by 3,537
Systems Analysis of Adverse Drug Events
Leape, L. L. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530010049034 · Cited by 1,404 · cited 1×
“In an analysis of 334 medication errors from 11 acute care wards, 38% of the problems occurred during administration by nursing personnel (Leape et al., 1995).”
Reducing the Frequency of Errors in Medicine Using Information Technology
Bates, D. W., Cohen, M., Leape, L. L., Overhage, J. M., Shabot, M. M., & Sheridan, T. (2001) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2001.0080299 · Cited by 959 · cited 2×
“Prior studies suggest that scanning of bar codes to verify patient and medication information may reduce medication errors, but the evidence is primarily based on self-reported medication errors and it is unclear how well the findings generalize across different hospitals (Bates et al., 2001; Johnson, Carlson, Tucker,…”
Result(2018) · CRC Press eBooks · doi:10.1201/9780203751725 · Cited by 573
An alternative strategy for studying adverse events in medical care
Andrews, L. B., Stocking, C., Krizek, T., Gottlieb, L., Krizek, C., Vargish, T., & Siegler, M. (1997) · The Lancet · doi:10.1016/s0140-6736(96)08268-2 · Cited by 525 · cited 1×
“Medication errors are the most commonly documented cause of adverse events in hospital settings (Leape et al., 1991), with rates ranging from 3.7% based on chart review (Brennan et al., 1991) to 17.7% based on direct observation (Andrews et al., 1997).”
BackgroundInfluentialPatterson, E. S., Cook, R. I., & Render, M. L. (2002) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1061 · Cited by 370
Self-citation
Research works printed but not linked: 1
- Johnson, C. L., 2002, Journal of Healthcare Informatics Management, 16, 46
Cited by
The Technology Acceptance Model: Its past and its future in health care
Holden, R. J., & Karsh, B.-T. (2010) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2009.07.002 · Cited by 2,669
“Numerous cases of underuse, resistance, workarounds and overrides, sabotage, and even abandonment are evidence for this claim [21–28].”
Koppel, R., Wetterneck, T., Telles, J. L., & Karsh, B.-T. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2616 · Cited by 685
Alter, S. (2014) · Communications of the Association for Information Systems · doi:10.17705/1cais.03455 · Cited by 249
Evolving Work Routines: Adaptive Routinization of Information Technology in Healthcare
Goh, J. M., Gao, G. (., & Agarwal, R. (2011) · Information Systems Research · doi:10.1287/isre.1110.0365 · Cited by 282
Nurses’ workarounds in acute healthcare settings: a scoping review
Debono, D. S., Greenfield, D., Travaglia, J. F., Long, J. C., Black, D., Johnson, J., & Braithwaite, J. (2013) · BMC Health Services Research · doi:10.1186/1472-6963-13-175 · Cited by 247
“To illustrate, in studies comparing medication administration workarounds across wards, not checking patient identification [64] and scanning a ‘surrogate’ wristband, which is not on a patient [6] were found to be more common in long-term care wards suggesting that the imperative to check patient identification was le…”
BackgroundInfluentialLaumer, S., Maier, C., & Weitzel, T. (2017) · European Journal of Information Systems · doi:10.1057/s41303-016-0029-7 · Cited by 183
Work-arounds in health care settings: Literature review and research agenda
Halbesleben, J. R. B., Wakefield, D. S., & Wakefield, B. J. (2008) · Health Care Management Review · doi:10.1097/01.hmr.0000304495.95522.ca · Cited by 229
“systems are regularly bypassed, often because they are perceived as an unnecessary demand on nurses’ time (Patterson et al., 2006).”
BackgroundA systematic review of safety violations in industry
Alper, S. J., & Karsh, B.-T. (2009) · Accident Analysis & Prevention · doi:10.1016/j.aap.2009.03.013 · Cited by 177
Waterson, P., Robertson, M. M., Cooke, N. J., Militello, L., Roth, E., & Stanton, N. A. (2015) · Ergonomics · doi:10.1080/00140139.2015.1015622 · Cited by 178
Technology Implementation and Workarounds in the Nursing Home
Vogelsmeier, A. A., Halbesleben, J. R. B., & Scott-Cawiezell, J. R. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2378 · Cited by 172
“To address this problem, many nurses engage in problem-solving behaviors that involve bypassing new technology or adapting work process so as to minimize disruption in work flow.(19,20) These problem-solving behaviors have been conceptualized as workarounds (WA); this study explores the manner in which technological W…”
BackgroundCompliance with the WHO Surgical Safety Checklist: deviations and possible improvements
Rydenfält, C., Johansson, G. I., Odenrick, P., Akerman, K., & Larsson, P. (2013) · International Journal for Quality in Health Care · doi:10.1093/intqhc/mzt004 · Cited by 191
“[21] investigated compliance with the WHO Checklist relying on reports of its usage sent to the researchers offering indirect data on the extent to which the checklist is used, but not the directly observed practice that might include workaround strategies [22].”
MethodExploring the persistence of paper with the electronic health record
Saleem, J. J., Russ, A. L., Justice, C. F., Hagg, H., Ebright, P. R., Woodbridge, P. A., & Doebbeling, B. N. (2009) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2009.04.001 · Cited by 145
“[25] E.”
BackgroundHolden, R. J. (2011) · Cognition, Technology & Work · doi:10.1007/s10111-010-0141-8 · Cited by 133
“One commonly reported adaptation is the use of workaround strategies to deal with blocks in performance (Ash et al. 2004; Koppel et al. 2008; Patterson et al. 2006; Vogelsmeier et al. 2008), a phenomenon found in this study as well (see Sect.”
BackgroundA systematic review of the impact of health information technology on nurses’ time
Moore, E. C., Tolley, C. L., Bates, D. W., & Slight, S. P. (2020) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocz231 · Cited by 125
Elfering, A., Semmer, N. K., & Grebner, S. (2006) · Ergonomics · doi:10.1080/00140130600568451 · Cited by 127
“Safe care is associated with procedural efficiency, implementation of evidence-based standards and the use of tools designed to reduce the likelihood of medical error (such as computerized medication orders and bar-coded patient identification (e.g. Patterson et al. 2006).”
MethodAnderson, J. E., Ross, A. J., Back, J., Duncan, M. D., Snell, P., Walsh, K., & Jaye, P. (2016) · Pilot and Feasibility Studies · doi:10.1186/s40814-016-0103-x · Cited by 152
Debono, D., Taylor, N., Lipworth, W., Greenfield, D., Travaglia, J., Black, D., & Braithwaite, J. (2017) · Implementation Science · doi:10.1186/s13012-017-0572-1 · Cited by 116
Helmons, P. J., Wargel, L. N., & Daniels, C. E. (2009) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp080357 · Cited by 147
“This is important, as implementation of BCMA technology can result in improvements in one error-prone process but have unintended consequences on others.(13,16,23,30) This study had several limitations.”
BackgroundInfluentialHolden, R. J., & Karsh, B.-T. (2009) · Behaviour & Information Technology · doi:10.1080/01449290601138245 · Cited by 128
“However, the initial enthusiasm over using HIT to improve patient safety has been tempered by published reports of HIT problems and failures (Han et al. 2005, Koppel et al. 2005, Nebeker et al. 2005, Nemeth and Cook 2005, Rothschild et al. 2005, McDonald 2006, Patterson et al. 2006).”
BackgroundDeLucia, P. R., Ott, T. E., & Palmieri, P. A. (2009) · Reviews of Human Factors and Ergonomics · doi:10.1518/155723409x448008 · Cited by 145
“For example, it was observed that bar code medication administration, a technology designed to make certain that patients get the correct drug, dose, and path of delivery at the right time, resulted in the development of nurses’ workaround strategies in order to increase efficiency and achieve on-time delivery status…”
BackgroundTechnological and Organizational Adaptation of EMR Implementation in an Emergency Department
Park, S. Y., Chen, Y., & Rudkin, S. (2015) · ACM Transactions on Computer-Human Interaction · doi:10.1145/2656213 · Cited by 107
“… systems [Ash et al. 2004; Boulus and Bjorn 2010; Cyert and March 1963; Hersh 1999]; bar code medication administration systems [Koppel et al. 2008; Patterson et al. 2006]; a computerized medication dispensing system [Azad and King 2008]; and a computerized prescription order entry system [Zhou…”
BackgroundHalbesleben, J. R. B., Savage, G. T., Wakefield, D. S., & Wakefield, B. J. (2010) · Health Care Management Review · doi:10.1097/hmr.0b013e3181d116c2 · Cited by 100
Using a sociotechnical framework to understand adaptations in health IT implementation
Novak, L. L., Holden, R. J., Anders, S. H., Hong, J. Y., & Karsh, B.-T. (2013) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2013.01.009 · Cited by 96
“These findings suggest that gains in patient safety associated with BCMA may be eroded by risks introduced from workarounds, resulting in the need to alter the technology, the work process, or management policies related to medication management (10, 54).”
BackgroundFlanagan, M. E., Saleem, J. J., Millitello, L. G., Russ, A. L., & Doebbeling, B. N. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-000982 · Cited by 92
“Further work should be conducted to validate the new computer-based workaround discovered in this study.”
BackgroundInfluentialWhat Have We Learned About Interventions to Reduce Medical Errors?
Woodward, H. I., Mytton, O. T., Lemer, C., Yardley, I. E., Ellis, B. M., Rutter, P. D., Greaves, F., Noble, D. J., Kelley, E., & Wu, A. W. (2010) · Annual Review of Public Health · doi:10.1146/annurev.publhealth.012809.103544 · Cited by 112
The role of continuous quality improvement and psychological safety in predicting work-arounds
Halbesleben, J. R. B., & Rathert, C. (2008) · Health Care Management Review · doi:10.1097/01.hmr.0000304505.04932.62 · Cited by 92
“For example, work-arounds of bar code medication administration systems have been widely documented (cf. McDonald, 2006; Patterson et al., 2006; Wideman et al., 2005), including such behaviors as copying patient bar codes to keep them in a central location (thus avoiding the bedside scan that checks whether the medica…”
BackgroundThe administration of blood components: a British Society for Haematology Guideline
Robinson, S. E., Harris, A., Atkinson, S., Atterbury, C., Bolton‐Maggs, P. H. B., Elliott, C., Hawkins, T., Hazra, E., Howell, C., New, H. V., et al. (2017) · Transfusion Medicine · doi:10.1111/tme.12481 · Cited by 103
“…safety is enhanced and that the systems are not open to any unintended risks and do not enable users to inappropriately override IT instructions (Davies et al., 2006; Patterson et al., 2006; Litchner et al., 2010; Andres et al., 2011; Murphy et al., 2012; Nuttall et al., 2013; McDonald, 2014).”
BackgroundHolden, R. J., Rivera-Rodriguez, A. J., Faye, H., Scanlon, M. C., & Karsh, B.-T. (2013) · Cognition, Technology & Work · doi:10.1007/s10111-012-0229-4 · Cited by 88
“Operational problem solving (and more broadly, adaptive behavior) is a key component of cognitive work (Mumaw et al. 2000; Patterson et al. 2006b; Vicente et al. 2001).”
BackgroundMethodResultCognitive ergonomics, socio-technical systems, and the impact of healthcare information technologies
Lawler, E., Hedge, A., & Pavlovic-Veselinovic, S. (2011) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2011.02.006 · Cited by 92
Seibert, H. H., Maddox, R. R., Flynn, E. A., & Williams, C. K. (2014) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp130332 · Cited by 73
Mansour, S., & Tremblay, D. (2019) · Personnel Review · doi:10.1108/pr-07-2017-0224 · Cited by 85
Elkin, P., Pelayo, S., Beuscart, R., & Beuscart-Zéphir, M.-C. (2007) · Yearbook of Medical Informatics · doi:10.1055/s-0038-1638535 · Cited by 74
“Opportunistic interviews (embedded in the observations, to have the user explain his thoughts while completing or just having completed a task) [86].”
BackgroundMethodInfluentialHolden, R. J., Brown, R. L., Scanlon, M. C., & Karsh, B.-T. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000754 · Cited by 72
Nurses' Satisfaction With Medication Administration Point-of-Care Technology
Hurley, A. C., Bane, A., Fotakis, S., Duffy, M. E., Sevigny, A., Poon, E. G., & Gandhi, T. K. (2007) · JONA The Journal of Nursing Administration · doi:10.1097/01.nna.0000285114.60689.02 · Cited by 73
Patterson, E. S. (2018) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720818762546 · Cited by 59
“This workaround is dangerous in that the unlabeled medications in an unlabeled cup could be documented as administered but never received by the patient (Patterson, Rogers, Chapman, & Render, 2006).”
BackgroundSelf-citationHaraldseid-Driftland, C., Billett, S. R., Guise, V., Schibevaag, L., Alsvik, J. G., Fagerdal, B., Lyng, H. B., & Wiig, S. (2022) · BMC Health Services Research · doi:10.1186/s12913-022-08451-y · Cited by 70
“Similar to other resilience in healthcare studies [59, 60], this study found that the complex demands, competing interests and a diversity of stakeholders focusing on different outcomes resulted in the need to choose some type of adjustment of practice over another.”
ResultA typology of electronic health record workarounds in small-to-medium size primary care practices
Friedman, A., Crosson, J. C., Howard, J., Clark, E. C., Pellerano, M. B., Karsh, B., Crabtree, B. F., Jaén, C. R., & Cohen, D. J. (2014) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2013-001686 · Cited by 70
Observation for assessment of clinician performance: a narrative review
Yanes, A. F., McElroy, L. M., Abecassis, Z. A., Holl, J. L., Woods, D. M., & Ladner, D. P. (2015) · BMJ Quality & Safety · doi:10.1136/bmjqs-2015-004171 · Cited by 60
Factors associated with workarounds in barcode‐assisted medication administration in hospitals
van der Veen, W., Taxis, K., Wouters, H., Vermeulen, H., Bates, D. W., van den Bemt, P. M. L. A., & the BCMA Study Group (2020) · Journal of Clinical Nursing · doi:10.1111/jocn.15217 · Cited by 59
“Other research identified circumstantial factors for performing workarounds but focused mainly on the usability of the BCMA system (Debono et al., 2013; Holden, Rivera-Rodriguez, Faye, Scanlon, & Karsh, 2013; Patterson, Rogers, Chapman, & Render, 2006).”
BackgroundSafety checklist compliance and a false sense of safety: new directions for research
Rydenfält, C., Ek, Å., & Larsson, P. A. (2013) · BMJ Quality & Safety · doi:10.1136/bmjqs-2013-002168 · Cited by 69
Holden, R. J., Brown, R., Alper, S. J., Scanlon, M. C., Patel, N., & Karsh, B. (2011) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2011.02.007 · Cited by 63
“Indeed, we might hypothesize based on research on human behavior [61–63], health care process acceptance [64,65], and BCMA [45,31] that favorable process perceptions resulted in greater acceptance of the process by nurses, in improved job satisfaction, and in more effective patient care, whereas…”
BackgroundResultvan Onzenoort, H. A. W., van de Plas, A., Kessels, A. G. H., Veldhorst-Janssen, N. M. L., van der Kuy, P. H. M., & Neef, C. (2008) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp070368 · Cited by 59
“First, workload is associated with workarounds.(22,23) A few workload-related reasons were related to time, but most were related to technical problems.”
BackgroundMethodStudy of Nurse Workarounds in a Hospital Using Bar Code Medication Administration System
Rack, L. L., Dudjak, L. A., & Wolf, G. A. (2011) · Journal of Nursing Care Quality · doi:10.1097/ncq.0b013e318240a854 · Cited by 61
Westbrook, J. I., & Baysari, M. T. (2015) · Yearbook of Medical Informatics · doi:10.15265/iy-2015-011 · Cited by 46
“decision support systems [49], barcode medication administration systems [50]).”
BackgroundAcute care nurses’ perceptions of electronic health record use: A mixed method study
Strudwick, G., Hall, L. M., Nagle, L., & Trbovich, P. (2018) · Nursing Open · doi:10.1002/nop2.157 · Cited by 56
Human Factors and Health Information Technology: Current Challenges and Future Directions
Kannampallil, T., & Patel, V. L. (2014) · Yearbook of Medical Informatics · doi:10.15265/iy-2014-0005 · Cited by 57
Nurses' behaviors and visual scanning patterns may reduce patient identification errors.
Marquard, J. L., Henneman, P. L., He, Z. G., Jo, J., Fisher, D. L., & Henneman, E. A. (2011) · Journal of Experimental Psychology Applied · doi:10.1037/a0025261 · Cited by 61
Organizational Workflow and Its Impact on Work Quality
Cain, C. H., & Haque, S. N. (2008) · Europe PMC (PubMed Central) · Cited by 59
Voshall, B., Piscotty, R., Lawrence, J., & Targosz, M. (2013) · JONA The Journal of Nursing Administration · doi:10.1097/nna.0b013e3182a3e8ad · Cited by 53
“001).(13) Nurses’ use of BCMA technology was studied from a human factors viewpoint by Carayon and colleagues(14) in a 472-bed Midwestern academic hospital.”
BackgroundSelf-reported violations during medication administration in two paediatric hospitals
Alper, S. J., Holden, R. J., Scanlon, M. C., Patel, N., Kaushal, R., Skibinski, K. A., Brown, R., & Karsh, B. (2012) · BMJ Quality & Safety · doi:10.1136/bmjqs-2011-000007 · Cited by 47
Nurse workarounds in the electronic health record: An integrative review
Fraczkowski, D., Matson, J., & Lopez, K. D. (2020) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaa050 · Cited by 51
“Narrative 7 Patterson (2006)68 3.”
BackgroundInfluentialBehind Human Error: Taming Complexity to Improve Patient Safety
Carayon, P. (2006) · doi:10.1201/9781482269505-42 · Cited by 45
“To see some of these techniques in action in health care see the studies in Nemeth et al., 2004 and Patterson et al., 2005).”
MethodNovak, L. L., Anders, S., Gadd, C. S., & Lorenzi, N. M. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000575 · Cited by 36
Qualitative ergonomics/human factors research in health care: Current state and future directions
Valdez, R. S., McGuire, K., & Rivera, A. J. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.01.016 · Cited by 37
“…a x x x x x 75 Lai et al. (2006) a x x x x 76 Lippa et al. (2008) a x x x 77 Miller et al. (2009) a x x x 78 Morag et al. (2012) a x x x x x 79 Patterson et al. (2006) a x x 80 Story et al. (2008) a x x 81 Wolf et al. (2006) a x x Sub-total 13 1 4 3 13 0 1 1 2 5 82 International Journal of…”
BackgroundInfluentialHardmeier, A., Tsourounis, C., Moore, M., Abbott, W. E., & Guglielmo, J. B. (2014) · Journal for Healthcare Quality · doi:10.1111/jhq.12071 · Cited by 35
Evaluation of a BCMA’s Electronic Medication Administration Record
Staggers, N., Iribarren, S., Guo, J., & Weir, C. R. (2015) · Western Journal of Nursing Research · doi:10.1177/0193945914566641 · Cited by 36
“Researchers indicate a consistent lack of compliance with BCMAprescribed procedures including failure to scan patients’ wrist bands or even pasting patient barcodes to a cart/chart/wall, not following procedures when completing stat orders, or bypassing scanning completely (Harrington, Clyne, Fuchs, Hardison, & Johnso…”
BackgroundEnabling Medication Management through Health Information Technology
(2011) · SciVee · doi:10.4016/37397.01 · Cited by 35
Usability evaluation of the SMART application for youth with mTBI
Dexheimer, J. W., Kurowski, B. G., Anders, S. H., McClanahan, N., Wade, S. L., & Babcock, L. (2016) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2016.10.007 · Cited by 36
A Safe Practice Standard for Barcode Technology
Leung, A. A. C., Denham, C. R., Gandhi, T. K., Bane, A., Churchill, W. W., Bates, D. W., & Poon, E. G. (2014) · Journal of Patient Safety · doi:10.1097/pts.0000000000000049 · Cited by 40
Song, L., Park, B., & Oh, K. M. (2015) · CIN Computers Informatics Nursing · doi:10.1097/cin.0000000000000143 · Cited by 35
“However, nonadherence to BCMA process is still a persistent problem in hospitals,(16,18,20,21) and beyond the workaround obstacles, other factors that may inhibit adherence are still unknown.(6,16,17,22) This study evaluated the relationship between the acceptance of BCMA technology and patient safety culture (PSC).”
BackgroundImproving central line maintenance to reduce central line-associated bloodstream infections
Drews, F. A., Bakdash, J. Z., & Gleed, J. R. (2017) · American Journal of Infection Control · doi:10.1016/j.ajic.2017.05.017 · Cited by 27
Yuan, C. T., Nembhard, I. M., & Kane, G. C. (2020) · Social Science & Medicine · doi:10.1016/j.socscimed.2020.113002 · Cited by 27
How Do Simulated Error Experiences Impact Attitudes Related to Error Prevention?
Breitkreuz, K. R., Dougal, R., & Wright, M. C. (2016) · Simulation in Healthcare The Journal of the Society for Simulation in Healthcare · doi:10.1097/sih.0000000000000174 · Cited by 32
Karsh, B., Holden, R., Escoto, K. H., Alper, S. J., Scanlon, M. C., Arnold, J., Skibinski, K. A., & Brown, R. (2009) · International Journal of Human-Computer Interaction · doi:10.1080/10447310902864993 · Cited by 30
Recognising and responding to ‘cutting corners’ when providing nursing care: a qualitative study
Jones, A., Johnstone, M., & Duke, M. M. (2016) · Journal of Clinical Nursing · doi:10.1111/jocn.13352 · Cited by 28
“…expense of high standards’ (‘Cut corners’ 2010, p. 174), cutting corners is now commonly associated with violations, deviations from established rules, procedures and norms in a range of industries – including healthcare (Walton 2004, Patterson et al. 2006, Carthey et al. 2011, Alper et al. 2012).”
BackgroundSamaranayake, N., Cheung, S. T. D., Cheng, K., Lai, K. N., Chui, W. C. M., & Cheung, B. M. Y. (2014) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2014.03.001 · Cited by 32
“[25] E.”
BackgroundRoydhouse, S., Carland, J. E., Debono, D. S., Baysari, M. T., Reuter, S. E., Staciwa, A. J., Sandhu, A., Day, R. O., & STOCKER, S. L. (2021) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.14844 · Cited by 25
Tsai, S., Sun, Y.-C., & Taur, F. (2010) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2010.07.002 · Cited by 24
“It has shown that one in five nurses would enter the patient’s social security number by keyboard instead of scanning the bar code wristband, which caused near misses could not be intercepted accurately [9].”
BackgroundMörike, F., Spiehl, H. L., & Feufel, M. A. (2022) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/00187208221087013 · Cited by 27
“…took place between June and October 2019, and both the number of observation hours and the duration of the interviews are comparable to data collected in previous studies of comparable scope and complexity (Kiossis et al., 2020; Patterson et al., 2006; Patterson, 2018; Ventres et al., 2006).”
BackgroundMethodResultScanning for Safety: An Integrated Approach to Improved Bar-Code Medication Administration
EARLY, C., Riha, C., MARTIN, J., LOWDON, K. W., & HARVEY, E. M. (2011) · CIN Computers Informatics Nursing · doi:10.1097/ncn.0b013e31821ef6c8 · Cited by 26
Writing plans instead of eliminating risks: How can written safety artefacts reduce safety?
Hutchinson, B., Dekker, S. W. A., & Rae, A. J. (2022) · Safety Science · doi:10.1016/j.ssci.2022.105738 · Cited by 25
Huang, Y.-H., & Gramopadhye, A. K. (2014) · Applied Ergonomics · doi:10.1016/j.apergo.2014.06.003 · Cited by 23
Beyond technology acceptance to effective technology use: a parsimonious and actionable model
Holahan, P. J., Lesselroth, B., Adams, K. A., Wang, K., & Church, V. (2015) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocu043 · Cited by 25
HUANG, H.-Y., & Lee, T. (2011) · CIN Computers Informatics Nursing · doi:10.1097/ncn.0b013e31820662c1 · Cited by 23
Bonner, L. M., Simons, C. E., Parker, L. E., Yano, E. M., & Kirchner, J. E. (2010) · Implementation Science · doi:10.1186/1748-5908-5-63 · Cited by 26
“Researchers have identified many barriers to implementation, including increased documentation time [12,13], interference with clinical workflow, apprehension about unintended negative consequences, financial concerns, physician resistance, maintenance costs, and inadequate information technology (IT) staff to support…”
Background“Drops Hollowing the Stone”: Workarounds as Resources for Better Task-Artifact Fit
Cabitza, F., & Simone, C. (2013) · Springer eBooks · doi:10.1007/978-1-4471-5346-7_6 · Cited by 24
Kelly, K. M., Harrington, L., Matos, P., Turner, B. S., & Johnson, C. (2015) · JONA The Journal of Nursing Administration · doi:10.1097/nna.0000000000000290 · Cited by 22
FitzHenry, F., Doran, J., Lobo, B., Sullivan, T. M., Potts, A. L., Feldott, C. C., Matheny, M. E., McCulloch, G., Deppen, S. A., & Doulis, J. (2011) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp090666 · Cited by 20
Wijnhoven, F., Hoffmann, P., Bemthuis, R., & Boksebeld, J. (2023) · International Journal of Information Management Data Insights · doi:10.1016/j.jjimei.2023.100163 · Cited by 18
Taft, T., Rudd, E., Thraen, I., Kazi, S., Pruitt, Z. M., Bonk, C., Busog, D.-N. C., Franklin, E. S., Hettinger, A. Z., Ratwani, R. M., et al. (2023) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocad031 · Cited by 19
Wei, S., Chen, X. S., & Rice, R. E. (2023) · Journal of Operations Management · doi:10.1002/joom.1267 · Cited by 18
Jaber, M. J., Al-Bashaireh, A. M., Kouri, O., Aldiqs, M. A., Alqudah, O. M., Khraisat, O. M. A., Bindahmsh, A. A., Alshodukhi, A. M., Almutairi, A. O., & Hakeem, N. (2024) · Global Journal on Quality and Safety in Healthcare · doi:10.36401/jqsh-24-16 · Cited by 17
“[15] 16–18] For example, pharmacy and nursing staff have reported that new procedures improved their workflows through planning; however, workflow issues may inhibit technology adoption.”
Williams, R., Aldakhil, R., BLANDFORD, A. E., & Jani, Y. H. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-044419 · Cited by 19
“A summary of these themes is presented in table 2.”
BackgroundInfluentialNurse Interruptions Pre- and Postimplementation of a Point-of-Care Medication Administration System
Stamp, K. D., & Willis, D. G. (2010) · Journal of Nursing Care Quality · doi:10.1097/ncq.0b013e3181d4a13f · Cited by 19
Anders, S. H., Miller, A., Joseph, P., Fortenberry, T. K., Woods, M. C., Booker, R., Slaughter, J., Weinger, M. B., & France, D. J. (2011) · Transfusion · doi:10.1111/j.1537-2995.2011.03185.x · Cited by 18
“In the real world, these design flaws are well known to cause user frustration and product dissatisfaction, which are primary motivations for nonuse, avoidance, and workarounds.(16-18,21) Inadequate information about the lack of checking against criteria of correctness in Product B’s ED RT functionality could lead to…”
BackgroundHuman factors engineering approaches to patient identification armband design
Probst, C. A., Wolf, L., Bollini, M. L., & Xiao, Y. (2015) · Applied Ergonomics · doi:10.1016/j.apergo.2015.06.018 · Cited by 15
Yang, Y., & Rivera, A. J. (2015) · Health Policy and Technology · doi:10.1016/j.hlpt.2015.08.003 · Cited by 15
“Existing research of interruptions in healthcare has primarily focused on human face-to-face interruptions, such as those initiated by staff [15] or patients [16], and technologyrelated interruptions, such as those mediated or created by cell phones [17,18], health information technology [19], alarms [20], or operatio…”
BackgroundQian, S., Yu, P., & Bhattacherjee, A. (2019) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2019.05.017 · Cited by 16
Scanning for Safety: An Integrated Approach to Improved Bar-Code Medication Administration
EARLY, C., Riha, C., MARTIN, J., LOWDON, K. W., & HARVEY, E. M. (2010) · CIN Computers Informatics Nursing · doi:10.1097/ncn.0b013e3181fc416d · Cited by 20
Marini, S. D., Hasman, A., & Abu‐Saad, H. H. (2009) · International Journal of Evidence-Based Healthcare · doi:10.1111/j.1744-1609.2008.00119.x · Cited by 16
Strudwick, G., Booth, R. G., Bjarnadóttir, R. I., Collins, S., & Srivastava, R. (2017) · BMJ Open · doi:10.1136/bmjopen-2017-018129 · Cited by 14
Pirnejad, H., Bal, R. A., & Shahsavar, N. (2010) · Studies in health technology and informatics · doi:10.3233/978-1-60750-588-4-719 · Cited by 13
“, workarounds) in order to improve problematic workflow as potential contributing factors for medical error [16, 17, 21, 25, 27-29, 31, 36].”
BackgroundChaturvedi, R. R., Etchegaray, J. M., Raaen, L., Jackson, J. S., & Friedberg, M. W. (2019) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/j.jcjq.2019.07.006 · Cited by 15
What should WHO be doing about patient safety and technology?
Mytton, O. T., Greaves, F., Stanton, E. A. I., & Donaldson, L. (2010) · BMJ Quality & Safety · doi:10.1136/qshc.2010.040428 · Cited by 12
“At a micro level, workarounds, occurring on the introduction of technology intended to make care safer, can make care less safe.(8) Healthcare professionals may resist the implementation of technological change.”
BackgroundMedication Safety in Hospitals: Avoiding Medication Errors in the Medication use Process
(2013) · Advances in Pharmacoepidemiology & Drug Safety · doi:10.4172/2167-1052.1000134 · Cited by 13
“Patterson et al reported that BCMA could give rise to new errors [70].”
BackgroundAdverse Medical Events in the NICU
Morriss, F. H. (2008) · NeoReviews · doi:10.1542/neo.9-1-e8 · Cited by 15
“... nurses by the automated removal of medications by the system, degraded coordination between nurses and physicians, nurses dropping activities to reduce workload during busy periods and giving priority to BSMA system-monitored activities when competing goals were encountered, (15) and “workarounds,” such as scannin…”
BackgroundThe Social Construction of Workarounds
Dunford, B. B., & Perrigino, M. B. (2018) · Emerald Group Publishing Limited eBooks · doi:10.1108/s0742-618620180000024003 · Cited by 16
Bozan, K., & Berger, A. (2018) · Hawaii International Conference on System Sciences (HICSS) · doi:10.24251/hicss.2018.384 · Cited by 14
“Healthcare providers may work around the medical information system for variety of reasons, such as saving time [12], addressing poor fitting workflow design [13], compensating for system shortcomings [14] and not finding the information provided sufficient [15].”
BackgroundGregory, L., Weston, L. E., Harrod, M., Meddings, J. A., & Krein, S. L. (2019) · American Journal of Infection Control · doi:10.1016/j.ajic.2019.03.034 · Cited by 12
Protocol Violations during Medication Administration in Pediatrics
Alper, S. J., Karsh, B.-T., Holden, R. J., Scanlon, M. C., Patel, N., & Kaushal, R. (2006) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193120605001004 · Cited by 10
“For example, the rule may be incorrect (Reason, Parker, & Lawton, 1998), the rule may not apply in the context of care, following the rule may require breaking another rule (Patterson et al., 2006), it may be significantly easier or faster to complete a task using violations, and in other cases the violations may be n…”
Background
Metadata
- Authors
- Patterson, E. S., Rogers, M. L., Chapman, R. J., & Render, M. L.
- Affiliations
- The Ohio State University (US)
- Cincinnati VA Medical Center (US)
- University of Cincinnati (US)
- Venue
- Human Factors: The Journal of the Human Factors and Ergonomics Society
- Publisher
- SAGE Publications
- Published
- 2006-03
- Volume
- 48
- Issue
- 1
- Pages
- 15-22
- ISSN
- 0018-7208 (ISSN-L)
- 1547-8181
- OpenAlex
- W1964029476
- Cited by
- 157
- References
- 15
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 4 · 2022: 8 · 2021: 5 · 2020: 4 · 2019: 7 · 2018: 7 · 2017: 10 · 2016: 8 · 2015: 13 · 2014: 12 · 2013: 13 · 2012: 13
- FWCI
- 12.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Human Factors The Journal of the Human Factors and Ergonomics Society (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Health Services Research and Development
- U.S. Food and Drug Administration
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- barcode medication administration, medication errors, acute care nursing, long-term care nursing, patient identification, Veterans Affairs hospitals, medication administration, adverse events
- MeSH terms
- Electronic Data Processing, Long-Term Care, Medication Errors, Medication Systems, Hospital, Prospective Studies, United States, United States Department of Veterans Affairs, Observation, Guideline Adherence
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.