CoChat

Minimum Detectable Change in Gait Velocity during Acute Rehabilitation following Hip Fracture

Hollman, John H., Beckman, Bryce A., Brandt, Rachel A., Merriwether, Ericka N., Williams, Rachel T., Nordrum, Jon T. · 2008 · Journal of Geriatric Physical Therapy
Cited by 99

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: Early ambulation and rehabilitation are recommended for patients undergoing surgical fixation of hip fracture. Gait velocity may be used as an outcome measure for these patients during acute rehabilitation. As an outcome measure, an estimate of meaningful change (responsiveness) in gait velocity for these patients, however, has not been described. The minimum detectable change (MDC) is a value that represents true change in a measure beyond that accounted for by measurement error. The purpose of this study was to quantify MDC in gait velocity as an index of responsiveness for persons in the acute stage of rehabilitation following hip fracture. METHODS: The study design was a descriptive cohort study with one repeated measure. A volunteer sample of 16 subjects over the age of 65, at a mean of 4.7 days postsurgical fixation of unilateral hip fracture, participated in the study. The study was conducted in an acute care rehabilitation practice in a large, tertiary care hospital. We measured gait velocity with the 10-meter walk test, estimated test-retest reliability with an intraclass correlation coefficient and quantified responsiveness of gait velocity as the MDC at a 95% level of confidence. RESULTS: Mean gait velocity was 15 cm/s and the test-retest reliability coefficient was equal to 0.823. The MDC in gait velocity during acute rehabilitation following surgical repair for hip fracture was 8.2 cm/s. CONCLUSIONS: Self-selected gait velocity in patients during acute rehabilitation following surgical fixation for hip fracture must improve by 8.2 cm/s or more to designate the change as being real change beyond the bounds of measurement error.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1519/00139143-200831020-00003

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 99

Metadata

Authors
Hollman, J. H., Beckman, B. A., Brandt, R. A., Merriwether, E. N., Williams, R. T., & Nordrum, J. T.
Venue
Journal of Geriatric Physical Therapy
Published
2008
Volume
31
Issue
2
Pages
53-56
ISSN
1539-8412 (ISSN-L)
OpenAlex
W2064568181
Cited by
99
References
4
FWCI
2.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Minimum Detectable Change in Gait Velocity during Acute Rehabilitation following Hip Fracture. https://app.cochat.ai/papers/10.1519/00139143-200831020-00003
The paper
Hollman, J. H., Beckman, B. A., Brandt, R. A., Merriwether, E. N., Williams, R. T., & Nordrum, J. T. (2008). Minimum Detectable Change in Gait Velocity during Acute Rehabilitation following Hip Fracture. Journal of Geriatric Physical Therapy. https://doi.org/10.1519/00139143-200831020-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.