The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Validity and Interunit Reliability of 10 Hz and 15 Hz GPS Units for Assessing Athlete Movement Demands
Abstract
The purpose of this study was to assess the validity and interunit reliability of 10 Hz (Catapult) and 15 Hz (GPSports) Global Positioning System (GPS) units and investigate the differences between these units as measures of team sport athlete movement demands. A team sport simulation circuit was completed by 8 trained male participants. The movement demands examined included: total distance covered (TD), average peak speed, and the distance covered, time spent, and the number of efforts performed low-speed running (0.00-13.99 km · h(-1)), high-speed running (14.00-19.99 km · h(-1)), and very high-speed running (>20.00 km · h(-1)). The degree of difference between the 10 Hz and the 15 Hz GPS units and validity was assessed using a paired samples t-test. Pearson's correlations were also used for validity assessment. Interunit reliability was established using percentage typical error of measurement (%TEM) and intraclass correlations. The findings revealed that 10 Hz GPS units were a valid (p > 0.05) and reliable (%TEM = 1.3%) measure of TD. In contrast, the 15 Hz GPS units exhibited lower validity for TD and average peak speed. Further, as the speed of movement increased the level of error for the 10 Hz and 15 Hz GPS units increased (%TEM = 0.8-19.9). The findings from this study suggest that comparisons should not be undertaken between 10 Hz and 15 Hz GPS units. In general, the 10 Hz GPS units measured movement demands with greater validity and interunit reliability than the 15 Hz units, however, both 10 Hz and 15 Hz units provided the improved measures of movement demands in comparison to 1 Hz and 5 Hz GPS units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Movement patterns in cricket vary by both position and game format.
Petersen, C. J., Pyne, D., Dawson, B., Portus, M., & Kellett, A. (2010) · Journal of Sports Sciences · doi:10.1080/02640410903348665 · Cited by 182 · cited 1×
“This is especially the case as Catapult Innovations and GPSports are currently the 2 most commonly used and commercially available GPS units for professional team sports (1,13,15,24).”
Method
Cited by
Oxendale, C. L., Twist, C., Daniels, M., & Highton, J. (2016) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2015-0406 · Cited by 54
Metadata
- Authors
- Johnston, R. J., Watsford, M. L., Kelly, S. J., Pine, M. J., & Spurrs, R. W.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2014-06
- Volume
- 28
- Issue
- 6
- Pages
- 1649-1655
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2135114179
- Cited by
- 447
- References
- 1
- FWCI
- 17.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity and Interunit Reliability of 10 Hz and 15 Hz GPS Units for Assessing Athlete Movement Demands. https://app.cochat.ai/papers/10.1519/jsc.0000000000000323
- The paper
- Johnston, R. J., Watsford, M. L., Kelly, S. J., Pine, M. J., & Spurrs, R. W. (2014). Validity and Interunit Reliability of 10 Hz and 15 Hz GPS Units for Assessing Athlete Movement Demands. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0000000000000323
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.