No Difference in 1RM Strength and Muscle Activation During the Barbell Chest Press on a Stable and Unstable Surface
The DOI matches its Crossref record.
Abstract
Exercise or Swiss balls are increasingly being used with conventional resistance exercises. There is little evidence supporting the efficacy of this approach compared to traditional resistance training on a stable surface. Previous studies have shown that force output may be reduced with no change in muscle electromyography (EMG) activity while others have shown increased muscle EMG activity when performing resistance exercises on an unstable surface. This study compared 1RM strength, and upper body and trunk muscle EMG activity during the barbell chest press exercise on a stable (flat bench) and unstable surface (exercise ball). After familiarization, 13 subjects underwent testing for 1RM strength for the barbell chest press on both a stable bench and an exercise ball, each separated by at least 7 days. Surface EMG was recorded for 5 upper body muscles and one trunk muscle from which average root mean square of the muscle activity was calculated for the whole 1RM lift and the concentric and eccentric phases. Elbow angle during each lift was recorded to examine any range-of-motion differences between the two surfaces. The results show that there was no difference in 1RM strength or muscle EMG activity for the stable and unstable surfaces. In addition, there was no difference in elbow range-of-motion between the two surfaces. Taken together, these results indicate that there is no reduction in 1RM strength or any differences in muscle EMG activity for the barbell chest press exercise on an unstable exercise ball when compared to a stable flat surface. Moreover, these results do not support the notion that resistance exercises performed on an exercise ball are more efficacious than traditional stable exercises.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The use of instability to train the core musculature
Behm, D. G., Drinkwater, E. J., Willardson, J. M., & Cowley, P. M. (2010) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h09-127 · Cited by 358
Behm, D. G., Muehlbauer, T., Kibele, A., & Granacher, U. (2015) · Sports Medicine · doi:10.1007/s40279-015-0384-x · Cited by 209
Evidence-Based Resistance Training Recommendations
Fisher, J., Steele, J., Bruce-Low, S., & Smith, D. (2011) · Medicina Sportiva · doi:10.2478/v10036-011-0025-x · Cited by 156
Saeterbakken, A. H., van den Tillaar, R., & Fimland, M. S. (2011) · Journal of Sports Sciences · doi:10.1080/02640414.2010.543916 · Cited by 100
Metadata
- Authors
- Goodman, C. A., Pearce, A. J., Nicholes, C. J., Gatt, B. M., & Fairweather, I. H.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2008-01
- Volume
- 22
- Issue
- 1
- Pages
- 88-94
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2060600418
- Cited by
- 94
- References
- 0
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.