The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Concurrent Validity of Four Clinical Tests Used to Measure Hamstring Flexibility
Abstract
The purpose of this study was to examine the concurrent validity of 4 clinical tests used to measure hamstring muscle length. A pilot study (N = 10) was conducted to determine the intratester reliability of 4 hamstring length measures: knee extension angle (KEA), sacral angle (SA), straight leg raise (SLR), and sit and reach (SR). The pilot investigation revealed good to excellent intratester reliability (intraclass correlation coefficient = 0.92-0.95) for each of the 4 tests. Eighty-one subjects (42 men and 39 women) participated in the main investigation. Subjects were randomly tested for each of 4 assessments of hamstring length. Concurrent validity was determined using linear regression, correlation, and kappa statistics. Correlation coefficients corresponding to the concurrent validity of the six combinations of the 4 clinical tests revealed poor to fair correlation (r = 0.45-0.65). The correlation coefficients for each pair from greatest to least were SR-SA= 0.65, SLR-SR = 0.65, KEA-SLR = 0.63, KEA-SR = 0.57, SLR-SA = 0.50, and KEA-SA = 0.45. Despite the common clinical use of these measures to assess hamstring length, these tests do not have sufficient concurrent validity to be used interchangeably or to assume that they each measure the same construct (hamstring length). Based on the results of this investigation and a review of the literature, the authors recommend that researchers, clinicians, and strength and conditioning specialists adopt the KEA test as the gold standard measure for hamstring muscle length.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Willy, R. W., Hoglund, L. T., Barton, C. J., Bolgla, L. A., Scalzitti, D. A., Logerstedt, D. S., Lynch, A. D., Snyder-Mackler, L., & McDonough, C. M. (2019) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2019.0302 · Cited by 418
The Case for Retiring Flexibility as a Major Component of Physical Fitness
Nuzzo, J. L. (2020) · Sports Medicine · doi:10.1007/s40279-019-01248-w · Cited by 127
Resistance Training vs. Static Stretching: Effects on Flexibility and Strength
Morton, S. K., Whitehead, J. R., Brinkert, R. H., & Caine, D. J. (2011) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31821624aa · Cited by 124
Reliability of V Sit-and-Reach Test Used for Flexibility Self-Assessment in Females
Cuberek, R., Machová, I., & Lipenská, M. (2013) · Acta Gymnica · doi:10.5507/ag.2013.004 · Cited by 29
Metadata
- Authors
- Davis, D. S., Quinn, R. O., Whiteman, C. T., Williams, J. D., & Young, C. R.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2008-03
- Volume
- 22
- Issue
- 2
- Pages
- 583-588
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2090796015
- Cited by
- 209
- References
- 1
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concurrent Validity of Four Clinical Tests Used to Measure Hamstring Flexibility. https://app.cochat.ai/papers/10.1519/jsc.0b013e31816359f2
- The paper
- Davis, D. S., Quinn, R. O., Whiteman, C. T., Williams, J. D., & Young, C. R. (2008). Concurrent Validity of Four Clinical Tests Used to Measure Hamstring Flexibility. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0b013e31816359f2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.