Computer-Aided Headspace Gas Chromatography Applied to Blood-Alcohol Analysis: Importance of Online Process Control
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper describes the analysis of ethanol in blood specimens from suspect drunk drivers and the associated quality assurance procedures currently used in Sweden for legal purposes. Aliquots of whole blood from two separate Vacutainer® tubes are diluted with 1-propanol as internal standard before analysis by headspace gas chromatography (HS-GC) with three different stationary phases: Carbopak B, Carbopak C, and 15% Carbowax 20 M. The actual HS-GC analysis, the integration of chromatographic peaks, the collection and processing of results, as well as the quality control tests involve the use of computer-aided techniques. The standard deviation of analysis (y) increased with concentration of ethanol in the blood specimen (x), and above 0.50 mg/g the regression equation was y = 0.0033 + 0.0153x. The prosecution blood-alcohol concentration (BAC) is the mean of three separate determinations made by different laboratory technicians working independently with different sets of equipment. A deduction is made from the mean analytical result to compensate for random and systematic errors inherent in the method. At BACs of 0.5 and 1.5 mg/g, which are the statutory limits in Sweden, the allowances currently made are 0.06 and 0.09 mg/g, respectively. Accordingly, the reduced prosecution BAC is less than the actual BAC with a statistical confidence of 99.9%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An enzymatic method for the microdetermination of ethanol
Bonnichsen, R. K., & Theorell, H. (1951) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365515109060572 · Cited by 281
Alcohol, drugs and traffic safety
(1982) · Accident Analysis & Prevention · doi:10.1016/0001-4575(82)90070-7 · Cited by 280
Cited by
Role of Variability in Explaining Ethanol Pharmacokinetics: Research and Forensic Applications
Norberg, ?., Jones, A. W., Hahn, R. G., & Gabrielsson, J. L. (2003) · Clinical Pharmacokinetics · doi:10.2165/00003088-200342010-00001 · Cited by 265
Self-citationA case of extreme agitation and death after the use of mephedrone in The Netherlands
Lusthof, K. J., Oosting, R., Maes, A., Verschraagen, M., Dijkhuizen, A., & Sprong, A. G. A. (2011) · Forensic Science International · doi:10.1016/j.forsciint.2010.12.014 · Cited by 190
“[3]; the main modification is that our method uses two GC columns with different polarities (DB-Wax and DB-624 from Agilent).”
MethodFaster absorption of ethanol and higher peak concentration in women after gastric bypass surgery
Klockhoff, H., Näslund, I., & Jones, A. W. (2002) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2002.01698.x · Cited by 182
Self-citationHolmgren, A., & Jones, A. W. (2010) · Forensic Science International · doi:10.1016/j.forsciint.2009.12.015 · Cited by 81
Self-citation
Metadata
- Authors
- Jones, A., & Schuberth, J.
- Venue
- Journal of Forensic Sciences
- Publisher
- ASTM International
- Published
- 1989-09-01
- Volume
- 34
- Issue
- 5
- Pages
- 1116-1127
- ISSN
- 0022-1198 (ISSN-L)
- OpenAlex
- W57133444
- Cited by
- 188
- References
- 2
- FWCI
- 10.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer-Aided Headspace Gas Chromatography Applied to Blood-Alcohol Analysis: Importance of Online Process Control. https://app.cochat.ai/papers/10.1520/jfs12748j
- The paper
- Jones, A., & Schuberth, J. (1989). Computer-Aided Headspace Gas Chromatography Applied to Blood-Alcohol Analysis: Importance of Online Process Control. Journal of Forensic Sciences. https://doi.org/10.1520/jfs12748j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.